3.3
- FINLANDIA CONTROL PANEL
There are many installation options for the Finlandia control panel. The maximum height of the control panel from the floor of the
sauna or the washroom floor is 1000 mm. The requirements of the electrical wiring standard SFS 6000, sections 7-701, are
applicable to the washroom. The ingress protection of the Finlandia panel is IPX4. The standard length of the control panel’s wire
is 10 metres.
SURFACE INSTALLATION:
In the sauna:
Install the surface box at a max height of 1000mm from the floor, and bring the wire out of the box. Screw the
panel’s mounting bracket to the box.
In the washroom:
no height restrictions, but the recommended height is 1500mm or at the
same height as the light switches.
Place the frame on the bottom of the box, connect the wires to the panel, and press the control panel to fasten it in the middle of
the frame. The panel will be attached to the bracket with magnets. Wiring instructions on page 11.