3.2 – THERMOSTAT SENSOR
THERMOSTAT SENSOR
C
ONNECTING THE WIRES
The thermostat sensor is wooden, its external casing is
made from black alder.
The external casing can be painted to match the sauna
panels using sauna wax, but remember to detach all
electronic components from the sensor before painting.
Electronic components could be damaged by paint.
Connect the connector to the designated connector on the
circuit board,
press the connector carefully all the way down.
Thermostat sensor are installed on the wall so that the distance between the ceiling and the upper edge of the
sensor is 100 mm. The sensor must be located 500 – 1000 mm from the upper edge of the sauna stove.
Furthermore, the sensor must be located at least 1000 mm from a non-directed incoming air valve or 500
mm from an incoming air valve which is located away from the device.
Illustration SECTION 4.1
Install the thermostat cable behind the panel in the air vent; if this is not possible,
use an installation baseboard. Make sure that the incoming air does not disturb the
heat sensor.
Do NOT cut the wire
from the thermostat’s side. The thermostat sensor does not
function if the wires are continued/reconnected. If the wire needs to be shortened,
shorten it from the connector’s side. In other cases, contact the technical support.
To the
connector
Blue
White
Red
Yellow
To the
circuit
board
1
2
3
4
T
HERMOSTAT SENSOR WIRE AND CONNECTOR