Getting Started

Storage

. The SR100 is supplied with the 

Traverse Unit (bottom) connected to the 
Control Unit (top). Before use, separate the 
Traverse Unit from the Control Unit.

Note:

 To prevent damage to the stylus, store 

the SR100 with the units connected.

The SR100 can be operated in two modes: 
Remote or Connected.  

Remote:

 Position the Control Unit 

within 40" (1 meter) of the Traverse 
Unit. Data is passed between the 
two units over the IrDA link.  
Note: Alignment between the 
Traverse Unit and Control 
Unit separation 

must be maintained during 
the measurement process.

Connected:

 In connected mode, 

the Control Unit is connected to the 
Traverse Unit before the measure-
ment is made, as shown. To connect 
the Control Unit to the Traverse Unit, 
insert the Control Unit as shown and 
tilt until the latch engages.

Inserting the Batteries

Remove battery covers as shown. Then, 
insert one 3V Lithium 2450 in to the Control 
Unit and three 3V Lithium 2450s in to the 
Traverse Unit as shown. 

Then replace the battery covers. After 
the batteries have been changed, there 
will be a short delay when the SR100 is 
turned on.

Turning On the SR100

When the Control Unit is not used for five 
minutes or more, it enters power save 
mode, turning the display off. Press any 
button to reactivate.

The Traverse Unit switches off com-
pletely after five minutes of inactivity.
To reactivate, press the On button. An LED 
will flash to confirm activation.

Caution:  

 - Use recommended 

    batteries only. 

 - Do not atttempt  

    to recharge used  

    batteries.  

 - Safely dispose of 

    used batteries

Control Unit

To separate, 

press here 

and tilt 

the Traverse 

 Unit as shown

Traverse Unit

Position the Traverse 
Unit on the surface 
as shown

Max. 40"  

(1 meter)  

separation

www.dmm.ca

1-866-960-9400

PRECISION IS OUR VISION

Digital Measurement Metrology, Inc

TM

Digital Measurement Metrology, Inc

Summary of Contents for SR100

Page 1: ...tatus Display Parameter Status Parameter Selector Mode Selector ArDA Windows Stylus Start Buttons ON Button Control Unit Traverse Unit www dmm ca 1 866 960 9400 PRECISION IS OUR VISION Digital Measurement Metrology Inc TM Digital Measurement Metrology Inc ...

Page 2: ...ges Inserting the Batteries Remove battery covers as shown Then insert one 3V Lithium 2450 in to the Control Unit and three 3V Lithium 2450s in to the Traverse Unit as shown Then replace the battery covers After the batteries have been changed there will be a short delay when the SR100 is turned on Turning On the SR100 When the Control Unit is not used for five minutes or more it enters power save...

Page 3: ...s All parameters not just the selected param eter are transmitted to the Control Unit at the same time and temporarily stored The stored results may then be stepped through using the select buttons Low Battery Indicators Set Up Procedure A new SR100 is fully set up out of the box However if the pick up is changed or another alteration is made field setup may be required using the following procedu...

Page 4: ...munication error Repeat operation E2 Measurement attempted when not calibrated Calibrate the Traverse Unit E3 Traverse Unit Oscillator fault Retry If fault is persistent contact Starrett E4 Traverse Unit Motor Positioning fault Retry If fault is persistent contact Starrett E5 Traverse Unit NVRAM Error Retry If fault is persistent contact Starrett E6 Traverse Unit Profile Over range Retry measureme...