PKG08812-QRGDFC 13
ENGLISH
MEMORY
Press
p
for Menu
Press
q
for Memory
Press
u
to Display results from memory
Press
u
to Clear results from memory
Press
u
to Export results from memory
Select your Units, press
t
to exit setup
*You must configure a softkey to display memory and statistics.
ABOUT
Press
q
for About
Press
u
to view the gage’s characteristics, serial
number, overload history and more.
Press
t
to exit setup
*The About setup is read-only.
TOLERANCE
Press
p
for Menu
Press
q
for Tolerance
Press
u
to Enable Tolerance
Press
u
to setup Limit 1, select Limit 1 value
pq
Press
u
to setup Limit 2, select Limit 2 value
pq
Press
t
to exit setup
COMMUNICATIONS
Press
q
for Communications (Comms)
Press
u
to specify the Data Channel method for exporting
results: USB, RS-232, or BT (Bluetooth
®
)
Press
q
to select RS-232
Press
q
to select RS-232 Baud Rate
Press
q
to setup direction sign (- default for Compression)
Press
q
to transmit Units
Press
q
to transmit Tolerance Limits
Press
t
to exit Comms setup
KEYS
Press
p
for Menu
Press
q
for Keys
Press
q
to specify a Sound for key presses
Press
q
to specify Softkey 1 function
Press
q
to specify Softkey 2 function
Press
t
to exit setup
*Certain gage functions require a softkey to be setup in order
to use the function- Memory, Statistics, Tests, Export (Send)
DISPLAY
Press
q
for Display
Press
u
to setup Auto Off
Press
u
to setup Backlight Brightness
Press
u
to setup Flip orientation (required for
TESTS feature)
Press
u
to setup Radix
Press
t
to exit Display setup
FILTERS
Press
q
for Filters
Press
u
to specify filter rate
Press
t
to exit Filter setup
SETTINGS
Press
p
for Menu
Press
q
for Settings, select Settings Type
TESTS
Press
p
for Menu
Press
q
for Tests
Press
u
to Enable Tests
Press
q
to your Test Method
Press
u
to enter specific Test Method options
*Refer to the User Manual for detailed instructions on using
the TESTS feature in your DFC.
MODES
Press
p
for Menu
Press
u
for Modes
Select your Mode, press
t
to exit setup
UNITS
Press
p
for Menu
Press
q
for Units
Select your Units, press
t
to exit setup
Management of the DFC memory is important to
ensure correct statistical analysis. Always clear old
results that are from a different test method.
CLEAR RESULTS FROM MEMORY
Results in memory may be cleared individually
or collectively. To clear an individual result from
memory, go to the STATS view. Select the results you
want to clear. Select the "X" (delete) key.
To clear all results from memory, go to the Memory
setup and select CLEAR. This will erase all results for
the gage's memory.
VIEW STATISTICS
You must configure a softkey with STATS to view
statistics. When results are saved to memory, you
press the STATS softkey to view results in memory
and the statistics for those results.
EXPORT RESULTS
You must configure a softkey with SEND to export
to an external device via Bluetooth, RS232 or USB.
Press the SEND softkey to export the displayed result.
GAGE SETUP