Instruction manual • Staring SM 125 •
11 <<
For an optimum adjustment of the mixer blades please
follow the instructions below:
1. Disconnect the mixer from the power supply and ensure
that it is not possible to engage it again.
2. Loosen the screws in the safety cover and remove
the
cover.
Fig.
4
3. Remove the centre cover A
Fig.
5
4. Tighten the screws.
5. Lift the mixing head from the mixing pan
6. Loosen the lock-nut A on bolt B. Fig. 5
7. Turn bolt B clockwise. One rotation lowers the mixing
head by approximately 2mm. Install the mixing head
and check the distance between the mixer blade and
the
bottom.
This distance should be approximately 2 mm.
>> 8. Adjustment of Mixer Blades
Fig. 4
A
A
B
Fig. 5