Starfire SF-HC25C3 User Manual Download Page 11

SF-HC25C3 Height Controller 

 

8

   

 

3.2.1

 

The

 

interface

 

definition

   

P1   

 

 

 

 

P2   

 

 

 

P3 

 
 
 

  figure 3-2-1 

table 3-2-1 

 

label  attribute 

explain 

note

 

P1 

Control 

input 

CNC system control input: automatically, 

lift, rev arc and success feedback, this 

interface on the 24 v power supply is 

isolated and P1, provided by the CNC. 

figure 

3-2-2

 

P2 

Input/outpu

Improve motor and collision signal and limit 

signals. 

figure 

3-2-3

 

P3 

The power 

input 

24 v power supply, its power consumption, 

improve the motor power, impact signals 

and limit the interfaces provide electricity. 

figure 

3-2-4

 

 

The 

power 

input 

Connected 
lifting motor 

Connect CNC 
system 

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 

www.fineprint.cn

Summary of Contents for SF-HC25C3

Page 1: ...SF HC25C3 Height Controller SF HC25C3 Cutting torch height controller The user manual V1 0 BeiJing starfirecnc control technology co ltd http www starfcnc com PDF pdfFactory Pro www fineprint cn...

Page 2: ...2 Electrical installation connect 4 Parameters illustration 4 1 Parameter setting instruction 4 2 Parameter specification 5 Use guide 5 1 Manual operation 5 2 Automatic operation 6 CNC system and blo...

Page 3: ...SF HC25C3 Height Controller 7 Troubleshooting 8 Appendix 9 Contact us PDF pdfFactory Pro www fineprint cn...

Page 4: ...ler 1 1 Purpose SF HC25C3 plasma cutting torch height controller is specially designed for portable plasma cutting machine cutting torch height automatic control module SF HC25C3 plasma cutting torch...

Page 5: ...if any specific illegal use do not represent the position of the company and refused to acknowledge its legal liability the consequences shall be borne by the users Safety warning is used to prevent t...

Page 6: ...cy of the height control Please careful carry away and please do not intense collision vibration in order to avoid damage to the product Please don not do something without authorization to open cutti...

Page 7: ...of digital tube display setting arc voltage and the arc pressure respectively concise and straightforward Setting parameters operating in total of three knobs Interface simply and control convenient i...

Page 8: ...tage feedback using linear photoelectric isolated independent power supply can very good compatibility with the partial pressure of various brands of imported plasma power supply integration and arc s...

Page 9: ...thod proximity switch normally open normally closed through the jumper cap set Highest accuracy 1V Box body size 271X221X70 5 Working environment temperature 10 60 Weight 2 5 Kg Detection system Built...

Page 10: ...on 3 1 Installation Highly controller bottom four M4 screw hole for fixed box body onto the mounting plate Its size is shown in figure 3 1 1 Figure the 3 1 1 host controller 3 2 the electrical install...

Page 11: ...nterface on the 24 v power supply is isolated and P1 provided by the CNC figure 3 2 2 P2 Input outpu t Improve motor and collision signal and limit signals figure 3 2 3 P3 The power input 24 v power s...

Page 12: ...wer supply is provided by the CNC 24VG power IO power supply provided by the CNC figure 3 2 3 Connecting the lifting mechanism label attribute explain note 24V POWER Offer 3 lines close to the switch...

Page 13: ...otective cap relay mode figure 3 2 4 POWER SUPPLY label attribute explain note 24VG input Switch power supply output negative side By the switch power supply provide 24V input The anode switch power s...

Page 14: ...utput Connection points linking piece rev arc control plasma arc input Connection points linking piece partial pressure output Points linking piece by default The partial pressure than 1 50 plasma arc...

Page 15: ...irectly as a set of highly Specific set number according to the selected power supply manufacturers provide technical parameter Settings 2 rev arc latency punch time should be used according to the ac...

Page 16: ...n to switch to the display window below and rotate the setting of the arc knob to change the parameter value Save and exit the parameter menu at p00 001 For example modify manual ascent speed P03 for...

Page 17: ...lt value 4 save as user default value P01 2 0 0 1 9 9 Unit V Accuracy of arc pressure adjustment P02 5 1 10 The sensitivity coefficient the greater the coefficient the higher the sensitivity P03 80 10...

Page 18: ...ioning switch is effective level low and effective 1 high and effective P28 0 0 1 The rise drop is effective level 0 is effective 1 is effective P29 0 0 1 Corner signal effective level 0 low and effec...

Page 19: ...the rising speed and the rising speed of the arc signal setting the range of 10 99 P09 the arc success feedback reference voltage actual arc pressure setting voltage voltage or actual arc pressure set...

Page 20: ...hile increasing a certain distance then fell to the height of the original can avoid the slag splashing up appropriately cut mouth adhesion 0 do not use this function the speed of P22 is used when lif...

Page 21: ...P31 start the arc with positioning movement 0 start arc not perform positioning action 1 time perform positioning action 5 Use guide Noun explanation control signal effectively refers to the input si...

Page 22: ...n self learning mode At this point you just need to adjust positioning height Do not use this function only sets the set of arc pressure to the 60 v 5 1 Manual operation manual up signal up Effective...

Page 23: ...to the plasma power such as waiting for a time after acquisition of arc voltage Start arc successful feedback the arc voltage within a certain amount of time keeping within the normal range is rev ar...

Page 24: ...SF HC25C3 Height Controller 21 PDF pdfFactory Pro www fineprint cn...

Page 25: ...ence is as follows M07 1 The cutting torch fell cutting torch down latency see M71 2 Open the arc switch 3 If the parameter setting is in the arc pressure detection from 0 no there is no any arc press...

Page 26: ...sition detection logic 0 Cutting positioning delay 0 Cutting up delay M70 1 second Cutting down delay M71 0 second Arc pressure detection 1 Perforated delay 0 The corner to close the height distance 1...

Page 27: ...ion line Above limit alarm lights Running more than mechanical upper limit Check the high limit switch Lower limit alarm lights Running more than mechanical lower limit Check low limit switch Up and d...

Page 28: ...SF HC25C3 Height Controller 25 PDF pdfFactory Pro www fineprint cn...

Page 29: ...26 8 Appendix 2 Line NPN normal shut series connection method 2 Line NPN normal open parallel methods 3 Line NPN normal shut series connection method 3 Line NPN normal open parallel methods PDF pdfFa...

Page 30: ...SF HC25C3 Height Controller 27 Controller supporting institutions Dimensions 82 x187x57 5mm Stroke 100m Weight 1 8kg PDF pdfFactory Pro www fineprint cn...

Page 31: ...trol technology co LTD Address HAITE garden 204 44 floors Shi Jing Shan district Beijing city Zip code 100041 Sales 010 88909875 QQ 1908817881 Technical support 010 88797100 Website http www starfcnc...

Reviews: