background image

PROPANE LP CONVERSION INSTALLATION INSTRUCTIONS

- 7 -

COPYRIGHT © 

2020

, STARFIRE DIRECT, ALL RIGHTS RESERVED.

4.

The flex lines attached to the Gas Key Valve have been pre-tightened. Using two

adjustable wrenches, make sure they are nice and tight and did not loosen during

shipping.

5.

Both of the flexible gas lines will have a FLR x FIP fitting hand tightened at the end.

Attach the Flex line with the yellow tape to the 

propane air mixer on bottom of

burner pan. 

Attach the other line to your gas supply.

REMEMBER: Use “Pipe Joint Compound” or “Yellow Gas Tape” on all NPT fittings. 

NEVER USE ON COMPRESSION THREADS!

8.

Using two ad

j

ustable wrenches, tighten the end of the first flexible gas line to the

compression fitting

 on your 

gas stub.

9.

Using two ad

j

ustable wrenches, tighten the end

 

of the second flexible gas line

(with yellow tape)

 to the compression

 

fitting on the bottom side of the 

Burner

System

.

 

M

a

k

e sure all fittings are tight and secure, then set

 

the 

Burner System

into the 

Fire Pit

.

10.

Test your connections for leaks before

 

first use.

 Use a soapy water solution.

11.

Before placing lava rock in burner pan, light your burner to ensure proper

ignition. For lighting instructions, see page 8.

Summary of Contents for FP-602416-BFCM

Page 1: ...Never use this appliance in an enclosed space such as a camper tent car or home NOTE TO INSTALLER Owner s Manual must be left with the consumer for future reference NOTE TO CONSUMER Owner s Manual must be saved for future reference 1 COPYRIGHT 2020 STARFIRE DIRECT ALL RIGHTS RESERVED PROPOSITION 65 WARNING ATTN CALIFORNIA RESIDENTS This product includes parts that may contain materials known to th...

Page 2: ...serious injury or death from fire burns explosions or carbon monoxide poisoning 2 COPYRIGHT 2020 STARFIRE DIRECT ALL RIGHTS RESERVED Clearances to Combustible Construction Sidewalls Ceiling Flooring 36 1 5 m from perimeter of unit Figure 1 80 1 5 m from top of unit to ceiling or overhang 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain w...

Page 3: ...r your Fire Pit Matches paper garbage or any other material must not be thrown on top of the lava rock fire glass logs or burner or into the flame I DO NOT use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water J Installation and r...

Page 4: ...UM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED The table below displays BTU ratings for the corresponding burner sizes and shapes H H Burner L Linear Burner PRE INSTALLATION AND PREPERATION SAFETY GUIDELINES 4 COPYRIGHT 2020 STARFIRE DIRECT ALL RIGHTS RESERVED BTU Rating Burner Size Shape 120 000 48 L8 L 165 000 36 HH 200 000 48 H H F Gas piping system must be sized to provide min...

Page 5: ...e Joint Compound or Yellow Gas Tape on all NPT fittings NEVER USE ON COMPRESSION THREADS 4 Using two adjustable wrenches tighten the end of the first flexible gas line to the compression fitting on your gas stub 5 Using two adjustable wrenches tighten the end of the second flexible gas line with yellow tape to the compression fitting on the bottom side of the Burner System Make sure all fittings a...

Page 6: ...installations Natural Gas installations refer to page 5 4 Install the propane air mixer before the 90 degree elbow on underside of burner pan See Fig 6 1 Note directional arrow on propane air mixer to orient in the correct direction for supply 5 Install the supplied Flare x FIP to the air mixer Connect your the flex line REMEMBER Use Pipe Joint Compound or Yellow Gas Tape on all NPT fittings NEVER...

Page 7: ...upply REMEMBER Use Pipe Joint Compound or Yellow Gas Tape on all NPT fittings NEVER USE ON COMPRESSION THREADS 8 Using two adjustable wrenches tighten the end of the first flexible gas line to the compression fitting on your gas stub 9 Using two adjustable wrenches tighten the end of the second flexible gas line with yellow tape to the compression fitting on the bottom side of the Burner System Ma...

Page 8: ... has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water OPERATING INSTRUCTIONS MANUAL MATCH LIT SYSTEMS ONLY READ IGNITION SAFETY INFORMATION BEFORE LIGHTING IGNITING THE FIRE PIT 1 Enter the included valve key into the key valve opening 2 Using a l...

Page 9: ... should be enough pressure to clean the concrete For normal spills a quick wipe up and gentle scrub with a cotton cloth or similar should be enough to clean For stains which contain dark colors or have been sitting longer than a normal spill you can use a mild soap Please also note that fissures can appear on the surface due to age and or exposure to the atmospheric conditions These commonly don t...

Page 10: ...shipped back without an RMA may be refused Our warranty does not cover items that have been damaged by over heating modification abuse improper storage installation or maintenance This warranty excludes claims for incidental or consequential damage and indirect collateral expenses arising from product defects or warranty recovery Starfire Direct is not responsible for damage incurred from use duri...

Page 11: ...By Starfire Direct Inc 866 578 8538 https starfiredirect com pages contact us This page is intentionally left blank ...

Reviews: