PROPANE LP CONVERSION
INSTALLATION INSTRUCTIONS
-
6
-
COPYRIGHT ©
2020
, STARFIRE DIRECT, ALL RIGHTS RESERVED.
FIG.
6
-
1
1.
P
lace
Fire Pit
over
Gas/Electrical Utilities
.
Remove the drop in burner from the box.
2.
T
he flex lines attached to the
Gas Key Valve
have been pre-tightened.
Untighten and
disconnect the
f
lexline from the elbow connected to the bottom of the pan.
3.
Open the include PROPANE CONVERSION KIT bag.
Assemble the supplied
propane air mixer.
NOTE:
These instructions are only for
Propane
Gas installations
.
Natural Gas installations
refer to page 5.
4.
Install the propane air
mixer
before
the 90 degree elbow on underside of burner pan.
See Fig
6-1.
Note directional arrow on propane air
mixer to orient in the correct
direction
for
supply.
5.
Install the supplied
Flare x FIP
to
the air mixer. Connect your
the flex
line.
REMEMBER
: Use “Pipe Joint Compound” or “Yellow Gas Tape” on all NPT fittings.
NEVER USE ON COMPRESSION THREADS!
FIG.
6
-
2
COMPLETED ASSEMBLY
Shown at right Fig. 6-3
PLEASE NOTE:
This Air Mixer will
not operate properly if
installed incorrectly or does
not have adequate air flow.
When installing your air mixer,
ensure the gas is flowing in the
proper direction indicated by
arrow.