background image

PROPANE LP CONVERSION

 INSTALLATION INSTRUCTIONS

-

6

 -

COPYRIGHT © 

2020

, STARFIRE DIRECT, ALL RIGHTS RESERVED.

FIG. 

6

-

1

1.

P

lace 

Fire Pit

 

over 

Gas/Electrical Utilities

.

 Remove the drop in burner from the box.

2.

T

he flex lines attached to the 

Gas Key Valve

 

have been pre-tightened. 

Untighten and

disconnect the 

f

lexline from the elbow connected to the bottom of the pan.

3.

Open the include PROPANE CONVERSION KIT bag.

Assemble the supplied 

propane air mixer.

NOTE:

 

These instructions are only for 

Propane

 Gas installations

.

 

Natural Gas installations 

refer to page 5.

4.

Install the propane air

 

mixer 

before

 the 90 degree elbow on underside of burner pan.

See Fig 

6-1.

 

Note directional arrow on propane air

 

mixer to orient in the correct

direction

 for 

supply.

5.

Install the supplied 

Flare x FIP

 to 

the air mixer. Connect your 

the flex

 

line.

REMEMBER

: Use “Pipe Joint Compound” or “Yellow Gas Tape” on all NPT fittings.

 

NEVER USE ON COMPRESSION THREADS!

FIG. 

6

-

2

COMPLETED ASSEMBLY

Shown at right Fig. 6-3

PLEASE NOTE:

 This Air Mixer will 

not operate properly if 

installed incorrectly or does 

not have adequate air flow.

When installing your air mixer, 

ensure the gas is flowing in the 

proper direction indicated by 

arrow.

Summary of Contents for FP-602416-BFCM

Page 1: ...Never use this appliance in an enclosed space such as a camper tent car or home NOTE TO INSTALLER Owner s Manual must be left with the consumer for future reference NOTE TO CONSUMER Owner s Manual must be saved for future reference 1 COPYRIGHT 2020 STARFIRE DIRECT ALL RIGHTS RESERVED PROPOSITION 65 WARNING ATTN CALIFORNIA RESIDENTS This product includes parts that may contain materials known to th...

Page 2: ...serious injury or death from fire burns explosions or carbon monoxide poisoning 2 COPYRIGHT 2020 STARFIRE DIRECT ALL RIGHTS RESERVED Clearances to Combustible Construction Sidewalls Ceiling Flooring 36 1 5 m from perimeter of unit Figure 1 80 1 5 m from top of unit to ceiling or overhang 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain w...

Page 3: ...r your Fire Pit Matches paper garbage or any other material must not be thrown on top of the lava rock fire glass logs or burner or into the flame I DO NOT use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water J Installation and r...

Page 4: ...UM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED The table below displays BTU ratings for the corresponding burner sizes and shapes H H Burner L Linear Burner PRE INSTALLATION AND PREPERATION SAFETY GUIDELINES 4 COPYRIGHT 2020 STARFIRE DIRECT ALL RIGHTS RESERVED BTU Rating Burner Size Shape 120 000 48 L8 L 165 000 36 HH 200 000 48 H H F Gas piping system must be sized to provide min...

Page 5: ...e Joint Compound or Yellow Gas Tape on all NPT fittings NEVER USE ON COMPRESSION THREADS 4 Using two adjustable wrenches tighten the end of the first flexible gas line to the compression fitting on your gas stub 5 Using two adjustable wrenches tighten the end of the second flexible gas line with yellow tape to the compression fitting on the bottom side of the Burner System Make sure all fittings a...

Page 6: ...installations Natural Gas installations refer to page 5 4 Install the propane air mixer before the 90 degree elbow on underside of burner pan See Fig 6 1 Note directional arrow on propane air mixer to orient in the correct direction for supply 5 Install the supplied Flare x FIP to the air mixer Connect your the flex line REMEMBER Use Pipe Joint Compound or Yellow Gas Tape on all NPT fittings NEVER...

Page 7: ...upply REMEMBER Use Pipe Joint Compound or Yellow Gas Tape on all NPT fittings NEVER USE ON COMPRESSION THREADS 8 Using two adjustable wrenches tighten the end of the first flexible gas line to the compression fitting on your gas stub 9 Using two adjustable wrenches tighten the end of the second flexible gas line with yellow tape to the compression fitting on the bottom side of the Burner System Ma...

Page 8: ... has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water OPERATING INSTRUCTIONS MANUAL MATCH LIT SYSTEMS ONLY READ IGNITION SAFETY INFORMATION BEFORE LIGHTING IGNITING THE FIRE PIT 1 Enter the included valve key into the key valve opening 2 Using a l...

Page 9: ... should be enough pressure to clean the concrete For normal spills a quick wipe up and gentle scrub with a cotton cloth or similar should be enough to clean For stains which contain dark colors or have been sitting longer than a normal spill you can use a mild soap Please also note that fissures can appear on the surface due to age and or exposure to the atmospheric conditions These commonly don t...

Page 10: ...shipped back without an RMA may be refused Our warranty does not cover items that have been damaged by over heating modification abuse improper storage installation or maintenance This warranty excludes claims for incidental or consequential damage and indirect collateral expenses arising from product defects or warranty recovery Starfire Direct is not responsible for damage incurred from use duri...

Page 11: ...By Starfire Direct Inc 866 578 8538 https starfiredirect com pages contact us This page is intentionally left blank ...

Reviews: