3
ELECTRICAL SHOCK ALERT.
Installation and checking of electrical circuits and hardware should only be performed by a qualified
licensed electrician.
CHEMICAL ALERT.
According to the state of California (Prop 65), this product contains chemicals known to the state of
California to cause cancer and birth defects or other reproductive harm.
SAFETY INFORMATION
CAUTION
PRODUCT DAMAGE MAY RESULT
This unit is not designed to handle any material other than human waste and toilet paper. The following list
includes, but is not limited to, items that should not be used with this system: Feminine sanitary products,
condoms, cotton balls and swabs, baby wipes, paper towels, etc.
PRODUCT DAMAGE MAY RESULT
Check to be sure your power source is adequate to handle the amperage requirements of the motor as indicated
on the pump or unit I.D. tag.
PRODUCT DAMAGE MAY RESULT
All plumbing (discharge and vent lines) must be installed to meet local codes. Unit must be vented. Do not use
an automatic plumbing vent device. Toilet will not flush.
PRODUCT DAMAGE MAY RESULT
Maximum operating temperature for models S1201 / S1202 must not exceed 104°F (40°C). Duty cycle should
not exceed 30 seconds on/30 seconds off.
PRODUCT DAMAGE MAY RESULT
Do not use cleaning products containing bleach in the toilet tank, toilet or attached fixtures as they will degrade
the pump seals.
WARNING
NOTES
:
Repair and service should be performed by an Authorized Service Station only. (Consult Factory.)
Recommended for installations up to 20’ total dynamic head. Consult Factory if installation is above 15’ vertical
height in 1” pipe. Mini-grinder Pump is designed for use in PowerFlush Optima units only. It is not designed for use
in any other application.
Mini-grinder pump is rated for 115V, 60 Hz, 7 Amps, .5 HP.
Pumps with the “UL” mark and pumps with the “US” mark are tested to UL Standard UL778. CSA Certified pumps
are certified to CSA Standard C22.2 No. 108. PowerFlush Optima units only. It is not designed for use in any other
application.
S1201, S1202 andS1203 toilets utilize 1.28 gallons per flush.
All fixtures connecting to the system must be on the same floor level.