-26-
TROUBLESHOOTING
8
Difficulties when the power is turned on
Symptom
Possible cause
Remedy
Power
Power cable is not
Properly plug
LED lamp Card is not
properly plugged in.
in power cable
does not
accepted
Power cable is broken.
light up.
Power fuse is blown
Card is
LED lamp is broken.
Consult technical
accepted
support
Card is not
Trouble with the main unit
accepted
Card failure
Power
Flaw or bent of card,
Use applicable card
LED lamp Card is
loss of card data,
light up.
accepted, but using other card than Visual card.
main unit
Stain on head
Clean the head up
does not
with cleaning card
properly run. System does not properly run.
Consult technical
Trouble with main unit.
support
Symptom
Possible cause
Remedy
Card is not ejected.
Card jamming
Reset the power
Card is not applicable
Use applicable card
Using other card then Visual card
Card data is erased by
Read/write error
a magnetized source
Card is bent
Issue new card
Card has flaws
Head is stained
Clean the head up
with cleaning card
Stain on cord
Clean the card
Trouble with main unit
Consult technical
support