background image

2

2M-Z10887 Owners Manual Fast Steamers

2

   

These symbols are intended to alert the user to the presence of  

important operating and maintenance instructions in the manual 

accompanying the appliance.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

NOTICE

Using any part other than genuine Star factory supplied parts relieves the  

manufacturer of all liability.

Star reserves the right to change specifications and product design without 

notice.  Such revisions do not entitle the buyer to corresponding changes,  

improvements, additions or replacements for previously purchased  

equipment.
Due to periodic changes in designs, methods, procedures, policies and  

regulations, the specifications contained in this sheet are subject  to change 

without notice.  While Star International Holdings Inc., Company exercises 

good faith efforts to provide information that is accurate, we are not 

responsible for errors or omissions in information provided or conclusions 

reached as a result of using the specifications.  By using the information 

provided, the user assumes all risks in connection with such use.

MAINTENANCE AND REPAIRS

Contact your local authorized service agent for service or required maintenance.  

 

Please record the model number, serial number, voltage and purchase date in the area below and have it ready when 

 

you call to ensure a faster service. 

 

SAFETY SYMBOL

Model No.

Serial No.

Voltage

Purchase Date

Business  

8:00 am to 4:30 p.m. Central Standard Time

 

Hours:

 

Telephone:

 

(314) 678-6303

Fax: 

 

(314) 781-2714

E-mail

  

[email protected]

                  

[email protected]

                 

[email protected]

Website:

        

www.star-mfg.com     

   

Service Help Desk

Authorized Service Agent Listing

Reference the listing provided with the unit

 

or

for an updated listing go to:

Website:

        

www.star-mfg.com    

 

E-mail

  

[email protected] 

Mailing Address:

    Star International Holdings Inc., Company

 

  10 Sunnen Drive 

  St. Louis, MO 63143  

  U.S.A  

Summary of Contents for FS1D

Page 1: ...1 FAST STEAMER MODEL FS1R FS1D FS1RT FS1DT FS2R FS2D FS2RT FS2DT FSFR FSFD FSFRT FSFDT Installation and Operation Instructions 2M Z10887 Rev E 10 24 2011 FSFRT FS2DT...

Page 2: ...ation that is accurate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user...

Page 3: ...5 20P X X FAST STEAMERS SPECIFICATIONS FRONT LOADING Model No A Width Inches CM B Height Inches CM C Depth Inches CM Approx Shp Weight Capacity inches W_x_D_x_H Direct Connect D Water Reservoir R FSF...

Page 4: ...hin 15 days Be certain to retain all contents plus external and internal packaging materials for inspection The carrier will make an inspection and will supply necessary claim forms These models are e...

Page 5: ...it Electrical Grounding Instructions This unit is equipped with a 3 prong grounded plug for your protection against shock hazard and must be plugged directly into a properly grounded 3 prong receptacl...

Page 6: ...amps provided 3 Holding the end opposite end over a bucket turn the water valve on until there is a good consistent supply of water this removes any air from the system and flushes it of any particles...

Page 7: ...the TEMP button to see current temperature TCT will FLASH until TSP Temperature Set Point is reached Alarm will sound 3 times when TSP is reached Note The Temperature Set Point is factory fixed at 40...

Page 8: ...nd to exit programming mode for this program Your program will not be saved if this step is not done within 10 seconds 7 Repeat process to program for additional programming Hi Limit Reset A hi limit...

Page 9: ...st Steamer generates instant steam by means of its open generator however the mineral deposits in the water are left behind A certain amount of deposits are needed for proper operation but a build up...

Page 10: ...5 oz lime 1 quart water use enough to cover bottom of the steam generator turn unit on and allow to evaporate Excessive Mineral Build up 4 Use a delimer solution which is safe for cast aluminum on the...

Page 11: ...teamers Rack Spatula Drip Pan Food Compartment Steam Generator Steam Ports Diffuser Generator Cover Top Cover Steam Vent Wing Nut Liner Typical Front Loading Steamer Shown IL1352 CLEANING FRONT LOADIN...

Page 12: ...he TEMP switch the LED will display PrOB Open Circuit Temperature Probe if a temperature probe is detected the output power will be shut off to all relays Press the TEMP switch the LED will display Pr...

Page 13: ...eaners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non stic...

Page 14: ...ACK WIRE TYP WHITE WIRE TYP SOLENOID RELAY 10 10 10 10 CORDSET 120V NEMA 5 15P SHOWN 120VC NEMA 5 20P NOT SHOWN B SK2250 Rev C 8 30 2007 Sheet 2 of 8 WIRING DIAGRAM FS1RT FS2RT COMPLETE 2 E11 E12 E1 E...

Page 15: ...ATE BLACK WIRE TYP WHITE WIRE TYP CORDSET 120V NEMA 5 15P SHOWN 120VC NEMA 5 20P NOT SHOWN B 3 1 A C C WIRING DIAGRAM FS1R FS2R SK2250 Rev C 8 30 2007 Sheet 4 of 8 1 1 2 2 NC3 N02 COM PUSH BUTTON B 2...

Page 16: ...ROL PANEL MOUNTING PLATE 1 5 5 6 HEATING ELEMENT SOLENOID STD MOUNTING POSITION SHOWN ON SIDE 4 4 A B A SOLENOID RELAY 12 V SOLENOID HIGH LIMIT THERMOSTAT BLACK WIRE TYP WHITE WIRE TYP 10 10 10 10 SK2...

Page 17: ...C D 3 16 MALE W WHITE WIRE LEADS DETAIL A TRANSFORMER INLINE FUSEHOLDER W 4AMP FUSE HIGH LIMIT THERMOSTAT BLACK WIRE TYP WHITE WIRE TYP 10 10 10 10 WIRING DIAGRAM FSFR SK2250 Rev C 8 30 2007 Sheet 8 o...

Page 18: ...Z10887 Owners Manual Fast Steamers STAR MANUFACTURING INTERNATIONAL INC Front Loading Steamer Main Body Assembly Rev B 1 18 13 SK2276 MODEL FSF 1 3 2 4 18 5 8 6 12 13 11 10 9 11 14 7 15 16 17 20 19 2...

Page 19: ...ADING 6 C9 FS0313 1 LINER ASSEMBLY FSF STEAMER FRONT LOADING 7 C9 FS0373 1 SPATULAASSEMBLY FRONT LOADING 8 2B Z10069 1 SPATULA WIRE ASSY FRONT LOADING 9 2C Z11259 1 BOLT CARRIAGE 3 8 16X1 SS FRONT LOA...

Page 20: ...0 2M Z10887 Owners Manual Fast Steamers STAR MANUFACTURING INTERNATIONAL INC Main Body Assembly Rev A 10 25 11 SK2281 MODEL FS1 FS2 1 2 3 4 5 6 7 8 10 9 11 12 13 14 17 16 15 16 20 22 21 18 23 24 19 21...

Page 21: ...FS1 9 2B Z10067 1 BOTTOM GRATE FOR 1 2 PAN FS1 2B Z5847 BUN RACK SMALL FS2 10 2D Z10054 1 1 2 PAN 2 5DP PERF SIDES FS1 2D Z10241 PAN 2 3 PERFORATED FS2 11 2C Z4251 2 SCREW 8 32X3 8 RHP SS FS1 FS2 12...

Page 22: ...NAL INC Control Box Assemblies Direct Connect Water Supply Rev B 6 21 12 SK2277 MODEL Fast Steamer 1 37 1 2 3 4 29 5 28 6 9 10 11 13 12 12 40 40 14 15 16 16 13 11 7 30 28 32 33 33 28 28 36 32 31 8 1 2...

Page 23: ...C Control Box Assemblies Reservoir Water Supply Rev A 6 21 12 SK2385 MODEL Fast Steamer 6 5 11 13 12 12 14 15 16 16 13 11 40 40 32 28 30 29 39 33 35 34 38 33 36 27 32 31 28 1 10 19 17 2 20 21 7 22 3 2...

Page 24: ...9 FS0341 CB BTM ASSY FS1 2 R EC FS1RT FS2RT C9 FS0343 CB BTM ASSY FS1 2 R MAN FS1R FS2R C9 FS0351 CB BTM ASSY FSF DC MAN FSFD 208 240V C9 FS0352 CB BTM ASSY FSF R EC FSFRT 208 240V C9 FS0360 CB BTM AS...

Page 25: ...S2R 120V 2U Z12875 PUMP OSCILLATING 115V 38AMPS mfg after 6 16 09 FS1RT 120V FS2RT 120V FS1R 120V FS2R 120V 28 2C Z10240 4 CLAMP HOSE 7 16 25 32 FS1D 120V FS1DT 120V FS1R 120V FS1RT 120V FS2D 120V FS2...

Page 26: ...26 2M Z10887 Owners Manual Fast Steamers STAR MANUFACTURING INTERNATIONAL INC Hinge Bracket Assembly Rev 8 28 07 SK2315 MODEL FS1 FS2 9 8 7 5 4 6 3 2 2 1...

Page 27: ...ig No Part Number Qty Description Application 1 2A Z10454 1 CENTER HINGE PIN FS1 2A Z10677 FS2 2 2A Z10214 4 PIN SPRING STEAMER ALL FS1 FS2 3 C9 Z10156 2 HINGE COVER BRACKET ALL FS1 FS2 4 2C Z10215 8...

Page 28: ...28 STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...