OPERATION TROUBLESHOOTING
If unit still does not operate contact the factory or one of its representatives or a local service
company for service or required maintenance.
DIAGNOSTICS FOR ELECTRONIC CONTROL STEAMERS
No Heat/No Steam
Shorted Temperature Probe
Less than 50 Ohms of resistance, if
a temperature probe is detected, the
output power will be shut-off to all relays.
Press the “TEMP” switch,
the LED will display
“PrOB”
Open-Circuit Temperature Probe if a temperature probe is detected, the
output power will be shut-off to all relays.
Press the “TEMP” switch,
the LED will display
“PrOB”
Relay Malfunction
If relay malfunction is detected when the
temperature is below 150°F (66°C) for
30 minutes or reaches 500°F (260°C).
The output power will be shut-off to both
relays unit the error no longer occurs.
The display will blink
“rELY”
Heat / No Steam
Temperature To Cool
Probe Temperature is 200°F (93°C) less
than the programmed set point.
Program & Heat Indicator
Light will Flash.