background image

66

GAS PIPING

Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the 

full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked 

to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male 

threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING: 

Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage 

the valve and affect its operation. When installing this appliance, all pipe and fittings must be free from 

all internal loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each griddle. It should be connected to the inlet pipe 

at the rear of the unit. The gas supply is then connected to it. The supply pressure to the regulator is 

not to exceed 1/2 psig.  If the gas pressure going to the regulator on the griddle exceeds 1/2 PSIG 

then another regulator must be installed to lower the pressure going to it.  This second regulator is not 

supplied with the griddle and is the customers responsibility.  All units are shipped for use with natural 

gas.  MA and TA Series Models are shipped set for 5" water column manifold pressure.  TSA and 

TSCHSA Series Models are shipped set for 5" water column manifold pressure.

MANUAL SHUT OFF VALVE

A manual shut off valve should be installed upstream from the manifold and within six feet of the 

griddle.  The shut-off valve is not supplied with the griddle and is the customers responsibility.

CONNECTING GAS SUPPLY LINE

The gas inlet of the griddle is sealed at the factory to prevent entry of dirt. Do not remove this seal until 

the actual connection is made to the gas supply line. 

PROPANE GAS - CONVERSION

This griddle is equipped with fixed orifice hoods and is shipped from the factory for use with natural 

gas. To convert to propane gas install the orifice hoods located behind the front panel as follows:

1.  Remove the front panel by removing the 

screws located on the front and bottom.

2.  Remove the burner mounting screws in the 

center of the combustion chamber access 

covers.

3.  Slide the burners back off the orifice hoods.
4.  Remove the natural gas orifice hoods and 

install the propane orifice hoods.

5.  Slide the burners back over the orifice hoods 

and reinstall the burner mounting screws.

6.  Reinstall the front panel.

7.  Set the pressure regulator to 10" (25.4cm) 

water column by removing the slotted or 

hex cap from the center of the regulator.  

Invert the plug and reinstall.  The letters "LP" 

will now be visible on the plug.  Reinstall the cap.  An 1/8" pipe plug is located on the manifold for 

attaching a pressure gauge.

CHECKING FOR GAS LEAKS

Check entire piping system for leaks. Soap and water solution or other material acceptable for the 

purpose, shall be used in locating gas leakage. 

Matches, candle flame or other sources of ignition shall not be used for 

locating gas leaks. 

PLUG

IL1199

Natural

Regulator

Propane / LP

CAUTION

Summary of Contents for 824MA

Page 1: ...ere should be posted in a prominentlocation detailedinstructions to be followed in the event the operator smellsgas Obtaintheinstructionsfrom the local gas supplier AVERTISSEMENT L installation inexacte le réglage le changement le service ou l entretien peuvent causer des dégats matériels des dommages ou la mort Lisez les instructions d installation d opération et d entretien complètement avant d ...

Page 2: ...urate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase d...

Page 3: ...t 2 60 000 573 sq in 3697sq cm 24 61cm 32 3 8 82 2cm 18 45 7cm 214lbs 97kg 244lbs 110 6kg 836TA 3 90 000 860 sq in 5545 sq cm 36 91 4cm 321lbs 145 4kg 366lbs 165 8kg 848TA 4 120 000 1146 sq in 7397 sq cm 48 122cm 428lbs 193 3kg 488lbs 221 1kg 860TA 5 150 000 1433 sq in 9242 sq cm 60 152 4cm 535lbs 242 4kg 610lbs 276 4kg 872TA 6 180 000 1719 sq in 11091 sq cm 72 182 9cm 642lbs 290 9kg 732lbs 331 7k...

Page 4: ...S INSTALLATION CODE OR CAN CGA B149 2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE NOTICE When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 or CAN CGA 6 16 and a quick disconnect device complying with either ANSI Z21 41 or CAN1 6 9 It must also be installed with restraining means to guard against...

Page 5: ...stand For installation carefully mark and cut off from the bottom of each leg using a straight cutting saw and de burr the inside tube wall prior to installing the caster Cut leg should measure 19 tube length not overall length Casters add about 6 1 4 of height to the unit Be sure to use approved strain relief means for protecting gas line connection If an appliance is equipped with casters and is...

Page 6: ...t off valve should be installed upstream from the manifold and within six feet of the griddle The shut off valve is not supplied with the griddle and is the customers responsibility CONNECTING GAS SUPPLY LINE The gas inlet of the griddle is sealed at the factory to prevent entry of dirt Do not remove this seal until the actual connection is made to the gas supply line PROPANE GAS CONVERSION This g...

Page 7: ...higher than the front to allow grease to roll off and flue gasses to escape out the rear DO NOT ATTEMPT TO LIGHT YOUR PILOT BURNER IF YOU EXPERIENCE A STRONG GAS ODOR MANUAL VALVE AND THROTTLING CONTROL MODELS 1 Turn off the main valve to the unit and wait 5 minutes to clear gas 2 Turn off all knobs and pilot valves 3 Turn on main valve to unit and light all pilots 4 Turn burner knobs to desired p...

Page 8: ...ng 4 Turn clockwise to decrease the flame height turn counterclockwise to increase the flame ELECTRICAL CONNECTION FOR SNAP ACTION AND CHROME SURFACE MODELS ONLY Snap action and chrome surface griddles are equipped with a three prong grounding plug The unit is designed for use on a 120 volt 15 amp 50 60 cycle AC single phase circuit only For protection against electrical shock the unit must be plu...

Page 9: ...p this Industrial Chrome griddle surface sparkling clean and performing at top efficiency DO NOT allow grease to accumulate as it will carbonize and become difficult to remove To prevent this condition the following cleaning suggestions should be followed 1 Remove excess oil and food regularly with a 4 100mm wide razor sharp type scraper and wipe surface with a damp cloth if desired 2 Following th...

Page 10: ...its authorized representatives that the chrome surface has been misused or abused or subjected to the following situations 1 Improperly installed 2 By pass adjustments not set properly on gas units allowing the appliance to overheat and discolor the chrome surface See by pass adjustment section 3 The misuse of any instrument or tool which scratches or makes indentations in the surface which could ...

Page 11: ... dans ce manuel sont susceptibles de changer sans préavis Quoique STAR Manufacturing exerce la bonne foi de fournir le renseignement correct STAR n est pas responsable pour les erreurs ou les omissions dans le renseignement pourvu ou les conclusions tirées à la suite de l utilisation des spécifications En utilisant le renseignement pourvu l utilisateur assume tous les risques en relation avec telle...

Page 12: ... CAS ÉCHÉANT NOTIFICATION Quandcetappareilestinstalléavecdesroulettes ildoitêtreinstalléaveclesroulettesfournies unconnecteur étant conforme à la norme ANSI Z21 69 ou au CAN CGA 6 16 et à un dispositif rapide étant conforme à la norme ANSI Z21 41 ou au CAN1 6 9 Il doit également être installé avec des moyens retenants de garder contre la transmission de la contrainte au connecteur Pourvotreproprep...

Page 13: ...débranché pour le service ou le nettoyage qu il doit être rebranché comme initialement installé avant l utilisation ATTENTION N INSTALLEZ PAS SANS ATTACHER ES PIEDS OU DES JAMBES ET L ETAGERE FOURNIES DE STAND IL2586 FR Vissez les jambes dans des écrous de support sur le bas Étagère De Stand De Plancher Raidissant des supports sur 860 et 872 modèles seulement Modèle de Stand de Plancher Contre Mod...

Page 14: ...tionnement expédié pour 5 pression de tubulure de colonne de l eau VANNE D ARRÊT MANUELLE Une valve coupée manuelle devrait être installée en amont de la tubulure et à moins de six pieds du gril La vanne d arrêt est pas fourni avec la crêpière et incombe aux clients RACCORD DE LA CANALISATION DE GAZ La prise de gaz du gril est scellée à l usine pour empêcher l entrée de la saleté Ne retirez pas ce...

Page 15: ...CAction Ajustez le pilote tellement approximativement 3 8 de l extrémité de thermocouple est entouré par la flamme pilote RÉGLAGE D CObturateur D CAir DE BRÛLEUR L obturateur d air de brûleur a une vis de blocage du côté inférieur du venturi Desserrez cette vis pour faire tout réglage et pour serrer la vis pour verrouiller l obturateur d air en place après que le réglage soit complet Tout réglage ...

Page 16: ...nant être opérationnelle Même avec la nourriture soigneuse d assaisonnement peut dans une certaine mesure bâton au gril la cuisine de la surface jusqu à ce que le plat de gril soit cassé dedans CUISINE Placez la molette de cadran à la configuration désirée Après une période de préchauffage de 30 minutes minimum le gril mettra à jour automatiquement la température choisie SOIN de GRIL SURFACES de N...

Page 17: ...u moins une fois par jour ATTENTION PRENEZ LE SOIN EXTRÊME EN MANIPULANT LE TIROIR DE REBUT CONTENANT LA GRAISSE CHAUDE ARRÊT DURANT LA NUIT MODÈLES MANUELS DE COMMANDE DE VALVE ET D CÉtranglement Arrêtez les molettes à la position de repos aux brûleurs de tour CASSEZ L CAction ET LES MODÈLES EXTÉRIEURS DE CHROME Tournez les molettes à la plus basse configuration et arrêtez le commutateur de puiss...

Page 18: ...Model 836MA Manual Control Ultra Max Gas Griddle SK2623 Rev A 12 11 12 1 2 10 6 3 12 11 13 14 15 6 16 17 18 19 20 21 6 22 23 24 29 3 4 5 6 7 25 26 27 28 8 9 2M Z16558 Ultra Max Gas Griddle ...

Page 19: ... 1 DRAWER SLIDE 824 836 848 2 860 872 14 G5 824014 1 GREASE DRAWER ASSY 824 836 848 2 860 872 15 2A Z4614 4 FOOT 2 IN D X 4 IN L Model 824MA 836MA 848MA 860MA 872MA Gas Griddle Manual Control Fig No Part No Qty Description Application 16 2M Z15805 1 ULTRA MAX LOGO 17 I4 Z15484 2 KNOB ASSEMBLY LG GAS KEYB 824MA 3 836MA 4 848MA 5 860MA 6 872MA 18 2M Z15245 2 KNOB LABEL ULTRAMAX 824MA 3 836MA 4 848MA...

Page 20: ...848TA T Stat Control Ultra Max Gas Griddle SK2631 Rev 12 11 12 1 3 4 29 12 15 16 17 13 18 6 19 20 21 22 19 23 25 26 9 27 28 24 14 6 33 32 31 30 37 36 35 34 6 5 6 7 8 9 3 10 11 3 6 2 2M Z16558 Ultra Max Gas Griddle ...

Page 21: ...ption Application 14 2K Z16583 1 MANIFOLD PIPE 824T 824TA 2K Z16584 MANIFOLD PIPE 836TA 836TA 2K Z16585 MANIFOLD PIPE 848TA 848TA 2K Z16586 MANIFOLD PIPE 860T 860TA 2K Z16587 MANIFOLD PIPT 872TA 872TA 15 G5 Z4897 1 DRAWER SLIDE 824TA 836TA 848TA 2 860TA 872TA 16 G5 824014 1 GREASE DRAWER ASSY 824TA 836TA 848TA 2 860TA 872TA 17 2A Z4614 4 FOOT 2 IN D X 4 IN L ALL 18 G5 Z16588 1 T STAT BRKT 824TA 82...

Page 22: ...VALVE LINCOLN BRASS 3817 824TA 3 836TA 4 848TA 5 860TA 6 872TA 33 2K Z5106 2 ELL 1 8P 3 8T BRASS 824TA 3 836TA 4 848TA 5 860TA 6 872TA 34 2C Z16361 2 HALF CLAMP 848TA 35 2C Z5556 2 WASHER 1 4 FLAT SS 848TA 36 2C Z5557 2 WASHER 1 4 SPLIT SS 848TA 37 2C Z5555 2 BOLT 1 4 20 X 75 HEX 848TA NI 2J Z4686 1 RGLTR GAS 3 4X3 4 CONVERTABLE PARTS LIST December 26 2013 Rev B Star International Holdings Inc Com...

Page 23: ...19 19 2M Z16558 Ultra Max Gas Griddle ...

Page 24: ...ap Action Thermal Spark Ultra Max Gas Griddle SK2650 Rev A 6 25 13 1 2 3 4 5 6 7 8 10 17 16 30 29 31 32 33 34 35 3 20 38 37 37 36 39 40 21 18 22 23 24 25 26 27 28 12 13 14 15 19 41 11 9 2M Z16558 Ultra Max Gas Griddle ...

Page 25: ... 2 G5 824012 CHUTE ASSEMBLY 1 824TSA 836TSA 848TSA 2 860TSA 872TSA 3 2T Z15211 T STAT 550F K TYPE 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 4 2F Z15290 GRIDDLE BURNER 40K 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 5 2J Z16497 HOOD BURNER ORIFICE 34 NAT 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 2J Z9288 ORIFICE 49 LP 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 6 G5 Z16155 BURNER COVER PLAT...

Page 26: ...5 872029 MANIFOLD ASSY 872TS CHS A 1 872TSA 17 2K Z15231 PIPE SEG 3 4x24 00 BI 1 18 2K Z4611 ELBOW 3 4 NPT 1 19 2K Z16511 MANIFOLD PIPE 824TSA 1 824TSA 2K Z16510 MANIFOLD PIPE 836TSA 1 836TSA 2K Z16509 MANIFOLD PIPE 848TSA 1 848TSA 2K Z16508 MANIFOLD PIPE 860TSA 1 860TSA 2K Z16507 MANIFOLD PIPE 872TSA 1 872TSA 20 2P 1453 PLUG PIPE 1 8NPT SQ HD 1 21 2K Z5106 ELL 1 8P 3 8T BRASS 1 824TSA 3 836TSA 4 ...

Page 27: ...39 2E Z15271 1 SPARK IGNITION CONTROL 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 2E Z15271 2 SPARK IGNITION HARNESS 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 2E Z15271 3 SPARK IGNITION WIRE 2 824TSA 3 836TSA 4 848TSA 5 860TSA 6 872TSA 40 G5 Z16347 IGNITION SUPPORT 824TS 1 824TSA G5 Z16212 IGNITION SUPPORT 836TS 1 836TSA G5 Z16348 IGNITION SUPPORT 848TS 1 848TSA G5 Z16349 IGNITION SUPPORT 860T...

Page 28: ...cleaners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is six 6 months on parts and ninety 90 days on l...

Reviews: