Page 36
The new elevation calibration procedure
1
is used to calibrate 8 Series (LED Screens), E-Series and
S-Series (LCD Screens) treadmill elevation. The procedure replaces the earlier procedure where spe-
cific values needed to be entered. For complete details on embedded screen maintenance modes,
see the OpenHub Service Manual. Embedded Calibration instructions are the same for all units.
Warning: Belt in motion is dangerous
Do not stand on or straddle belt during a calibration procedure.
Embedded Screen Elevation Calibration Procedure
Calibrates the incline of the treadmill:
1. While in Home Screen, press “
VOL Up, CH/TRK Up, and 3
” simultaneously.
2. Service Menu will now be displayed.
3. Select the Calibration and Setup sub-menu from the list
4. Enter the password
218
on the pop up window requesting a Password.
5. Select Incline Calibration on the Calibration and Setup screen.
6. Press
START
to begin the calibration.
7. After the Incline Calibration is completed, press
EXIT
; The Calibration And Setup screen appears.
8. Press
Cancel
to exit and go back to the Home Screen.
9. The Incline Calibration has been completed.
1
Procedure is duplicated from
https://support.corehandf.com/637-8469
, check online for any updates after publication.