6. Temperature and Humidity Control Operation -
a. Fahrenheit or Celsius Selection - The control will read cabinet air temperature in F°
or C°. To change this indication press and hold the
MODE
switch and then press
+
to
change the setting.
b. Pre-set Selection - This control comes from the factory with 6 programmed pre-set
selections indicated as Preset 1, etc. These correspond to the temperature and humidity
setting as indicated in the table below:
Cabinet Air
Preset No. Temp. Setting Humidity Setting
1
175F°
10
2
120F°
10
3
170F°
6
GENERAL OPERATING INSTRUCTIONS
1. Install inside food rack or pizza/pretzel shelves depending on the model
unit purchased. The shelves are in the enclosed accessory carton
(See Figure 1).
2. Plug the unit into a grounded 120 V.A.C. receptacle (230V receptacle for European
models).
LOCATION AND FUNCTION OF CONTROLS
The operating controls are located above the door on the side of the unit next to the water
fi
ll
(See Figure 2).
1. Temperature Indicator - Displays temperature
2. Water Level Indicators - When ON water level is too low
3. ON/OFF Switch - Activates lights, digital thermometer and air circulation system.
4. Low Water Light - When the light is ON this indicates that water must be added. The
fi
ll
light will also come on. Element shuts OFF until water is added.
4
175F°
6
5
150F°
5
6
150F°
5
To select Pre-Sets press and hold
MODE
then press
SELECT
to toggle through pre-sets.
Stop on the desired pre-set setting. For speci
fi
c food products, see the Recommended
Control Settings and Holding Times section.
c. Temperature and Humidity Programming- A pre-set can be changed. Hold
+
and
-
for
3 seconds until the current temperature is displayed. Push
+
up or
-
down to set the
desired cabinet temperature. Press
MODE
to display the humidity setting. Press
+
up or
-
down to set the desired humidity level. A setting of 5 will be about 25% relative
humidity. Press
MODE
to leave program.
By pressing and holding
MODE
and then
SELECT
different pre-sets can be
individually chosen and reset to a speci
fi
c temperature and humidity setting.
(Maximum temperature is 175°F and humidity 10).
NOTE
Using tap water will promote scaling that will eventually
cause clogging of water tubes and prevent the proper
operation of the Humidity Cabinet. The use of distilled
water will prevent scaling inside the water lines of the
cabinet.