Midilift XLplus
Maintenance Guide
Jan
2014
Issue
4
3
12.2
Pit buffer ................................................................................................................................................... 20
12.3
Tension Pulley.......................................................................................................................................... 20
12.4
Cabin floor................................................................................................................................................ 21
12.5
Pit clean.................................................................................................................................................... 21
13
MAINTENANCE INSTRUCTION – PHASE 4................................................................................................ 21
13.1
Brake lining .............................................................................................................................................. 21
13.2
Thorough clean ........................................................................................................................................ 22
14
5 YEAR MAINTENANCE CHECKS............................................................................................................... 22
14.1
Gearbox/motor detailed check ................................................................................................................. 22
14.2
Earth bonding, insulation and electrical visual......................................................................................... 22
14.3
Safety gear and overspeed governor (Full safety activation required) .................................................... 23
15
ADDITIONAL CHECKS ................................................................................................................................. 23
15.1
Autodialer ................................................................................................................................................. 23
15.2
Telephone ................................................................................................................................................ 24
15.3
Intercom ................................................................................................................................................... 24
15.4
Power door operator ................................................................................................................................ 24
15.5
Fire alarm shut down................................................................................................................................ 24
15.6
UPS .......................................................................................................................................................... 25
16
APPENDIX A.................................................................................................................................................. 26
16.1
Cabin operating panel (COP) removed.................................................................................................... 26
16.2
Upper floor landing controls ..................................................................................................................... 27
16.3
Ceiling removed - Important note: persons are note permitted to stand on car roof ............................... 28
16.4
COP and rear wall removed..................................................................................................................... 29
17
APPENDIX B.................................................................................................................................................. 30
17.1
Brake lining .............................................................................................................................................. 30
17.2
Overspeed governor activation tests (with remote test control)............................................................... 31
17.3
Overspeed governor activation tests (without remote test control) ......................................................... 32
17.4
Overspeed lift ........................................................................................................................................... 33
17.5
Set the lift to run at 80.0 Hz...................................................................................................................... 34
17.6
Re set the lift to run at 50.0 Hz ................................................................................................................ 34
17.7
Overload controller calibrations ............................................................................................................... 35
17.8
Overload alarm setup............................................................................................................................... 35
17.9
Safety chain switch locations ................................................................................................................... 36