56
7.1.3 Technical data WSL141
Hydro module
WSL141
Device
WSLHP7
WSLHP11
Version
Controller
TT3000 (MD1)
Device placement
Interior, wall
Electrical data
Single phase connection of internal unit
5)
Frequency
Hz
50
Rated voltage
V
~ 230
Max. operational current
A
11,8
Max. electrical power
kW
2,6
Z
max
14)
Ω
/
Fuses
12)
A
1 x C16
Electrical power cable
4)
mm
2
3 x 2,5
Electrical boiler
1 x 2 kW ~ 230 V
Three phase connection of internal unit
5)
Frequency
Hz
50
Rated voltage
V
3N ~ 400
Max. operational current
A
11,8
Max. electrical power
kW
6,6
Fuses
12)
A
3 x C16
Electrical power cable
4)
mm
2
5 x 2,5
Electrical boiler
3 x 2 kW ~ 230 V
Cooling system
Max. operational pressure
MPa
5,0 (50 bar)
Pipe connection, pipe for liquids
3/8
’’
Pipe connection, pipe for gas
5/8
’’
Primary side (heat source) – air
Heating and cooling
Range of operation
–
min. / max. air temperature
°C
Depending on the external air
– water unit
Secondary side (heat sink) – water
Min. / Max. pressure in the system
Mpa
0,1 / 0,3 (1,0 / 3,0 bar)
Recommended dimensions of
pipes of the device
7)
DN
25
Heating
Rated voltage
6)
m
3
/ h
1,0
1,4
Pressure drop at rated voltage
kPa
14
12
Range of operation
–
min. / max. water temperature
°C
25 / 58
Cooling
Range of operation
–
min. / max. water temperature
°C
7 / 25
Pipe connections for the water connection
Supply pipe system
R1'' (ext. u.)
Return line system
R1'' (ext. u.)
Pipe connections for the DHW connection
DHW
– hot water connection
R1'' (ext. u.)
DHW
– cold water connection
R1'' (ext. u.)
Volume
DHW Tank
l
/
Buffer tank
l
40
Dimensions and mass – transport
Dimensions (W x H x D)
mm
990 x 894 x 680
Mass
kg
81
Dimensions and mass – neto
Dimensions (W x H x D)
mm
607 x 774 x 499
Mass
kg
73
Noise
Level of sound power
dB (A)
35
Level of sound pressure at a
distance of 1 m
dB (A)
27
Communication
Connection between ext. and inter.
unit
Cable H05VV-F 4 x 0,75 mm
2
(IEC 60227-53) or similar
Connection to BMS
/
Connection to the internet
8)
UTP 5ea cable - connection RJ45 - Ethernet
Miscellaneous