15
Fig.13
PLUMBING (DHW MODEL ONLY)
The DHW Model must be connected to a gravity
system. Care should be taken to ensure that the
domestic hot water installation is correctly installed
and that it complies with all relevant codes of prac-
tice. If this appliances is being connected to an exist-
ing system, it is strongly recommended to check the
following:
(a) That the system is sound.
(b) That the pipe work is adequately insulated.
(c) Are there any modifications necessary to
make the domestic hot water system more
efficient.
Fig.14
DIRECT DOMESTIC CYLINDER
A 227 Litre (60 Gallon) direct domestic cylinder can
be connected to the DHW stove using copper or
stainless steel 28mm O.D. (1”) flow & return pipes.
We recommend that the cylinder is lagged along
with the pipework. We do not recommend the use of
a direct cylinder in areas where there is a high
concentration of lime or minerals in the water.
INDIRECT DOMESTIC CYLINDER
A 227 Litre (60 Gallon) indirect domestic cylinder
can be connected to the DHW stove using copper or
stainless steel 28mm O.D (1”) flow and return pipes.
We recommend that the cylinder is lagged along the
pipework.