SPECIFIC SAFETY INSTRUCTIONS

Warning!

 Do not use the air compressor in areas where 

there is a risk of explosion or fire from combustible 
materials.  The sparks generated from certain tools 
attached to air compressor can ignite combustible 
materials as well as flammable liquids, paint, varnish, 
petrol, flammable gases and dust of an explosive nature.  
As a precaution it is recommended that you consult an 
expert on a suitable fire extinguisher and its use.
• Do not attempt to modify the air compressor, guards or 

the supplied accessories in any way.

• Domestic air compressors are designed for intermittent 

operation. Ideally a 75% duty cycle.  (Meaning: 45 
seconds ON motor pumping and 15 seconds OFF, 
motor not pumping).  When the motor is pumping 
the attached air tool can not be used.  Only use the 
attached air tool while the compressor is not pumping.

• Stop using the attached tool as soon as the air 

compressor starts pumping.

• Fully assemble compressor before use.
• Always ensure your compressor is level and stable.   

Using your compressor on unlevel or unstable ground 
may cause it to tip over, this damage will not be covered 
under warranty.

• Never run this compressor without the wheels and 

rubber stopper being correctly fitted.

• Never use an extension cord with this compressor 

always use a longer air hose.

• Never connect to a generator which does not produce 

sufficient power, at least 5000W and has pure sine 
wave power output.

• Domestic air compressors are not designed for 

industrial / commercial applications.

• Domestic air compressors are not designed for 

continuous running. Always follow duty cycle - 75%.

• Avoid touching the pump area as it can become very 

hot and may burn.

• Ensure that the air compressor is disconnected from 

the mains supply when not in use, before servicing, 
lubricating, making changes and when changing 
attachments such as air hoses / tools.

• Always use the correct type of tool for the operation to 

be carried out.

• Never use the air compressor if any part of the unit is 

damaged.  Always have the air compressor serviced by  
an authorised service agent.

• Always wear safety eye, ear and respiratory protection 

when operating the air compressor.

• Allow the tank to completely fill before using the  

air compressor.

• If the air compressor makes an unfamiliar sound or 

vibrates excessively, switch the air compressor ‘OFF’ 
immediately and disconnect from the mains power 
supply. Investigate the possible cause or consult your 
authorised service facility.

• Always move the air compressor using the handle  

and wheels.

• Always use the air compressor on stable ground.
• This air compressor is designed to compress normal air.  

Never use to compress any other type (s) of gases.

• Never direct the jet of air or other liquids / gases 

towards your body, other persons or animals.

• Never direct the jet of air or other liquids / gases 

towards this air compressor.

• This air compressor is not suitable for pharmaceutical, 

food or sanitary purposes.

• This air compressor is not to be used to for filling scuba 

or oxygen air bottles or tanks.

• Always follow the instructions relating to the tools 

attached to this air compressor.

IMPORTANT

ELECTRICAL DATA

This air compressor is fitted with a sealed electrical connection plug that is compatible with the mains power supply 
for Australia / New Zealand and meets the requirements of international standards.  This air compressor must be 
connected to a supply voltage that is equal to that stated on the rating label.  If the mains power connection plug 
or power cord becomes damaged it must be replaced with a complete assembly that is identical to the original, and 
this must be replaced by an authorised service centre.  Always follow the Australian / New Zealand requirements for 
connection to the mains supply.  If in doubt always consult a qualified electrician.

Summary of Contents for SXCM27550323

Page 1: ...04078 02 20 MODEL NO SXCM27550323 AIR COMPRESSOR TWIN STACK 2 75HP 50L For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876...

Page 2: ...Place of Purchase Receipt Number Always check the air requirement of the tool wishing to be used to ensure that it is within this air compressor s air output SUGGESTED APPLICATIONS You may use most a...

Page 3: ...h parts and components of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same...

Page 4: ...rts of the product with parts and components of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished...

Page 5: ...or wax Always leave sufficient distance at least 5 metres between the air compressor and the work area especially when using tools designed for sanding or spraying liquids If needed use a longer air h...

Page 6: ...authorised service facility Keep handles clean dry and free from oil and grease Ensure that ventilation slots are kept clean and free from dust at all times Blocked ventilation slots can cause overhe...

Page 7: ...ards and safety requirements Repairs should only be carried out by qualified persons using original spare parts Failure to do so may result in considerable danger to the operator PERSONAL SAFETY Cloth...

Page 8: ...changes and when changing attachments such as air hoses tools Always use the correct type of tool for the operation to be carried out Never use the air compressor if any part of the unit is damaged A...

Page 9: ...ank drain tap 5 Castors 6 Safety valve not shown 7 Tank pressure gauge 8 Front handle 9 Pressure switch 10 On Off button red colour 11 Outlet pressure gauge 12 Air outlet nitto style socket 13 Outlet...

Page 10: ...HEELS To attach the caster wheels to the bracket located on the bottom of the tank 1 Undo the nut and remove the washer 2 Push through the bracket and replace the washer 3 Tighten the nut Pic 1 WHEELS...

Page 11: ...he red ON OFF switch on top of the pressure switch AIR FILTER The supplied air filter must be used Failure to do so may result in irreparable damage and will void the warranty Pic 3 To install 1 Caref...

Page 12: ...nitial pump up stage has finished you can use the compressor This compressor has a maximum pressure of 10 bar Always regulate the outlet air pressure to match your air tool Different air tools require...

Page 13: ...6 Slowly open the tank drain tap see page 16 This allows excess air and moisture water to vent 7 Leave the tank drain tap open This allows any moisture to drain while the air compressor is stored NOTE...

Page 14: ...ever up to horizontal NOTE Remember to seal the drain tap before starting the compressor Drain Tap Sealed OR To close and seal push lever up Right or left Drain tap opened un sealed AIR FITTING Pic 11...

Page 15: ...alve 1 95 BRC95OWV 10 Wheel Set 2 95 STWH 11 Drain Tap 1 95 BRC95DT 12 Caster Wheel 1 95 STCW Part Description Qty SMG Part No 14 Handle 1 95 STDDH 15 Unloading Tube Set 1 95 SXCM27550323UT 17 Pressur...

Page 16: ...and the Yellow and Black Diagonal Package Design are all trademarks of the Stanley Black Decker Inc or an affiliate thereof and are used under license Product manufactured and distributed by Smart Ma...