background image

10

E N G L I S H

 

t

 

Do not disassemble the charger; take it to an 
authorised service centre when service or repair 
is required.

of electric shock, electrocution or fire.

 

t

 

In case of damaged power supply cord the 
supply cord must be replaced immediately by the 
manufacturer, its service agent or similar qualified 
person to prevent any hazard.

 

t

 

Disconnect the charger from the outlet before 
attempting any cleaning. This will reduce the 
risk of electric shock.

 Removing the battery pack 

will not reduce this risk.

 

t

 

NEVER

 attempt to connect 2 chargers together.

 

t

 

The charger is designed to operate on the 
voltage specified in the Charger Specifications 
chart. Do not attempt to use it on any other 
voltage.

 Refer to your Charger Model No. for the 

correct specification.

SAVE THESE INSTRUCTIONS

s

r

e

g

r

a

h

C

  

.

9

The EBCB105 charger accepts EBC180, EBC181 & 
EBC183, 18 V Li-Ion battery packs.

This charger requires no adjustment and is designed 
to be as easy as possible to operate.

 g. 2)

 

1.  Plug the charger into an appropriate outlet 

before inserting the battery pack. (Refer to the 
Charger Specifications)

 

2.  Insert the battery pack (K) into the charger, 

making sure the pack is fully seated in the 
charger. The red (charging) light will blink 
continuously indicating that the charging-
process has started.

 

3.  The completion of charge will be indicated by 

the red light remaining ON continuously. The 
pack is fully charged and may be used at this 
time or left in the charger.

NOTE: 

To ensure maximum performance and life of 

of 10 hours before first use.

s

s

e

c

o

r

P

 

g

n

i

g

r

a

h

C

  

.

1

1

Refer to the table below for the state of charge of the 
battery pack.

State of charge

charging

–– –– –– ––

fully charged

–––––––––––––––––

hot/cold pack delay

–– 

t

 –– 

t

 –– 

t

 –– 

t

State of charge

x

problem pack or charger

t

 

t

 

t

 

t

 

t

 

t

 

t

 

t

 

t

 

t

 

t

 

t

 

problem power line

tt

 

tt

 

tt

 

tt

 

tt

 

tt

The charger will indicate faulty battery by refusing to 
light or by displaying problem pack or charger blink 
pattern.

NOTE:

and battery pack to be tested at an authorised service 
centre.

y

a

l

e

D

 

k

c

a

P

 

d

l

o

C

/

t

o

H

  

.

2

1

delay, suspending charging until the battery has 
reached an appropriate temperature. The charger then 
automatically switches to the pack charging mode. 
This feature ensures maximum battery life. STANLEY 
Engineered Fastening Li-Ion tools are designed with 
an Electronic Protection System that will protect the 
battery against overloading, overheating or deep 
discharge. The tool will automatically turn off if the 
Electronic Protection System engages. If this occurs, 
place the Li-Ion battery on the charger until it is fully 

will charge at that slower rate throughout the entire 
charging cycle and will not return to maximum charge 
rate even if the battery warms.

 

s

n

o

i

t

c

u

r

t

s

n

I

 

y

t

e

f

a

S

 

t

n

a

t

r

o

p

m

 

.

3

1

for All Battery Packs

When ordering replacement battery packs, be sure to 
include the catalogue number and voltage.

The battery pack is not fully charged out of the carton. 
Before using the battery pack and charger, read the 
safety instructions below and then follow the charging 
procedures outlined.

READ ALL INSTRUCTIONS

 

t

 

Do not charge or use the battery pack in 
explosive atmospheres, such as in the presence 
of flammable liquids, gases or dust.

 Inserting or 

removing the battery pack from the charger may 
ignite the dust or fumes.

 

t

 

Never force the battery pack into charger. Do 
not modify the battery pack in any way to fit 

may rupture causing serious personal injury.

 

t

 

Charge the battery packs only in designated POP® 
chargers.

Summary of Contents for POP PB3400

Page 1: ...POP PB3400 Battery Powered Blind Rivet Tool Battery Power Tool Prototype Instruction Manual Battery tool for Blind Rivets For Field Trial Use Only...

Page 2: ...Therefore STANLEY Engineered Fastening cannot be held liable for any damage resulting from deviations from the original specifications of the product The information available has been composed with...

Page 3: ...torage Recommendations 11 16 Labels on Charger and Battery Pack 11 17 Package contents 12 18 Description 12 19 Intended use 12 20 Electrical Safety 12 21 Using an Extension Cable 12 22 Assembly Adjust...

Page 4: ...A B C D E F G H I Serial no M 6 4 1 4 K2 K O P Q K Figure1 Figure2 Figure3 4...

Page 5: ...Figure4 5 24 R S T U V W AA AB Z AA AC AB Z E X D A B Y A Y A J Figure7 Figure6 Figure8 Figure5 Figure10 Figure9 AD AE 14 A B 23 27 C B...

Page 6: ...EBC180 battery 18 V 3 0 Ah size 6 4 8 3 16 700 1 000 1 500 size 8 6 4 1 4 350 500 750 depending on rivet material tool battery condition and work environment Placing capacity for different type rivet...

Page 7: ...eep the hands warm organisation of work patterns 0 8 1 C B E 3 8 1 C B E 1 8 1 C B E k c a p y r e t t a B s n o i s r e v l l a Batterytype Li Ion Voltage VDC 18 Capacity Ah 1 5 2 0 3 0 Weight kg 0 3...

Page 8: ...can be caught in moving parts E R A C D N A E S U L O O T R E W O P 4 4 a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and...

Page 9: ...t CAUTION Burn hazard To reduce the risk of injury charge only POP rechargeable battery packs Other types of batteries may overheat and burst resulting in personal injury and property damage CAUTION C...

Page 10: ...ery pack Stateofcharge charging fullycharged hot coldpackdelay t t t t Stateofcharge x problempackorcharger tttttttttttt problempowerline tttttttttttt The charger will indicate faulty battery by refus...

Page 11: ...nts of opened battery cells may cause respiratory irritation Provide fresh air If symptoms persist seek medical attention WARNING Burn hazard Battery liquid may be flammable if exposed to spark or fla...

Page 12: ...art of it Damage or personal injury could result DO NOT use under wet conditions or in presence of flammable liquids or gases DO NOT let children come into contact with the tool Supervision is require...

Page 13: ...crew that holds it in place then reassemble on the opposite side Be sure to securely tighten the screw N O I T A R E P O 5 2 Instructions for Use WARNING Always observe the safety instructions and app...

Page 14: ...ften as dirt is seen collecting in and around the air vents Wear approved eye protection and approved dust mask when performing this procedure WARNING Never use solvents or other harsh chemicals for c...

Page 15: ...ollection of used products and packaging allows materials to be recycled and used again Re use of recycled materials helps prevent environmental pollution and reduces the demand for raw materials Loca...

Page 16: ...601 Pulling Head Assembly 18 TP143 611 Spindle Clutch 19 TP144 676 Spindle Clutch Spring 20 TP144 659 Tail Guide 6 4mm 1 4 size Marking 8 21 TP143 612 Gear Housing Assembly 29 TP143 620 SA Second Shaf...

Page 17: ...A Nose Housing C g EBC 181 1 5 Ah Battery NA QW XE use QW with model no PB3400 GB C g EBC 180 3 0 Ah Battery NA QW XE use QW with model no PB3400 GB g PNT132 600 Hook PB2500 C Marked Parts are Consuma...

Page 18: ...18 ENGLISH 37 Exploded View Diagram...

Page 19: ...T Lok TP124 542 T Rivet Avex TP144 593 Avibulb 6mm TP144 593 Avibulb XT Avinox XT Klamp Tite BAPK seies TP144 593 Klamp Tite BAPKTR seies Closed End TP144 640 HR HT Rivet TP144 593 TP144 657 Interlock...

Page 20: ...lt 71210 16020 71210 16020 71210 16020 Q Rivet 07381 04701 07381 04701 07348 04701 07348 04701 T Lok 07381 04701 T Rivet Avex PRN811 Avibulb 6mm PRN811 Avibulb XT 71233 15001 Avinox XT 71233 15002 Kla...

Page 21: ...T Klamp Tite BAPK seies Klamp Tite BAPKTR seies Closed End HR HT Rivet Al Steel HR HT Rivet St St TP144 655 Marking 8K TP144 647 Marking 6 8K Interlock Hemlok Open End Stavex Monobolt Q Rivet T Rivet...

Page 22: ...allow to cool Mount battery and reset tool to home Tool does not return to initial position when switch is released Electrical malfunction Remove battery wait 5 seconds and reinsert Reset tool to home...

Page 23: ...D A B Mount the nose piece A Y A Place the blind rivet Y in the nose piece A Position the tool Press and hold the switch J until blind rivet is fully set J Close the lid E of the mandrel collector X Y...

Page 24: ...econtact distributor Manual Number Issue 2015 Stanley Black Decker Inc POP is a registered trade mark of Newfrey LLC Avdel Eurosert Avex Stavex Avinox Avibulb Interlock Klamp Tite Bulbex Monobolt TLo...