Final Tune-In Adjustments
• Refer to Attachment 8, and ANSI/BHMA A156.10, “American National Standard for Power Operated Doors” or
ANSI/BHMA A156.19, “American National Standard for Power Assist and Low Energy Power Operated Doors,”
or the most current ANSI/BHMA Standards.
• CYCLE and RECYCLE door several times to verify proper speeds and forces, and PERFORM adjustments in the
following order:
a. ADJUST close check cam.
b. ADJUST open speed.
c. ADJUST open check speed.
d. ADJUST “CLS” (close speed) rheostat.
e. ADJUST “CK” (close check speed) rheostat.
Note
: Adjustments to the “CK” (close check speed) rheostat also affect closing speed. Closing speed must
always be checked after adjusting close check speed.
f. ADJUST “CLS” (close speed) rheostat.
Caution
: To prevent motor overheating and premature motor failure, stall speed must not be
set too high.
g. ADJUST stall speed.
h. ADJUST torque.
i. ADJUST time delay.
Warning
: The Magic-Touch time delay must be set to at least 5 seconds to ensure compliance with
ANSI/BHMA A156.19 or most current ANSI/BHMA standards. “American National Standard for Power
Assist and Low Energy Power Operated Doors” specifications.
j. ADJUST Magic-Touch™ time delay.
k. ADJUST breakout and breakout status cams.
l. Refer to Attachment 8, and ENSURE all ANSI/BHMA, and UL compliance requirements are met.
m. POWER DOWN the door, POWER UP the door, and ENSURE that all settings have been stored
in the controller.
n. Verify that the correct Safety Logic has been selected for Sensor Monitoring and that JP200 is installed.
o. Please refer to Attachment 11 for MC521 Pro Controller Fine Tuning for adjustment recommendations.