© 2002, THE STANLEY WORKS. ALL RIGHTS RESERVED.
203959
Rev. F, 10/2/02
4 of 23
2.
PRECAUTIONS
2.1
If the Magic-Touch time delay is set to 2 seconds, a safety sensor
must
be installed to ensure
compliance with ANSI A156.19, “American National Standard for Power Assist and Low Energy
Power Operated Doors,” specifications.
3.
WIRING INSTRUCTIONS
3.1
Evaluating Power Requirements
3.1.1
EVALUATE door system power requirements as follows:
•
ENSURE power source is a dedicated 117 VAC, 50/60 Hz source with 20A
circuit rating per two-door system.
•
ENSURE power source is not shared with other equipment, i.e., cash registers,
EAS systems, or other electromagnetic interference generators.
3.2
Connecting Main Power Wiring
WARNING
To prevent injury to personnel, incoming electrical power to header must be deenergized before
connecting control box electrical harness to electrical service.
3.2.1
DEENERGIZE incoming electrical power to header.
3.2.2
Refer to Attachment 4, and, using the wire nut provided, CONNECT ground wire
assembly (P/N 711527) to electrical service ground wire.
3.2.3
In a concealed location inside the header (not visible from the exterior of the header),
DRILL a hole for a No. 8 screw.
3.2.4
INSTALL ground wire ring terminal and star washer onto the No. 8 screw provided,
and FASTEN screw, star washer, and ground wire to header.
3.2.5
In a concealed location inside the header, DRILL a second hole for a No. 8 screw.
3.2.6
INSTALL main harness (J1) ring terminal and star washer onto the No. 8 screw
provided, and FASTEN screw, star washer, and ground wire to header.
3.2.7
Using the wire nuts provided, CONNECT power pigtail assembly (712846) to electrical
service as follows:
•
CONNECT power pigtail assembly black wire to black (line) service wire.
•
CONNECT power pigtail assembly white wire to white (neutral) service wire.
3.2.8
ENSURE power pigtail assembly is
not
connected to main harness connector J1.