10- ENG
7
Release Air
from System
Release all
air from pump and
high pressure hose by
depressing trigger until a
steady stream of water is
present. Approximately
30 seconds.
8
Verify the Fuel
Switch is in the
ON Position
9
Verify the
Engine Switch
is turned to the
ON Position
OFF
ON
10
Move the
Choke to the
CLOSED Position
11
Pull the Recoil
Starter Grip
Pull the recoil starter
grip to start the engine.
12
Move the
Choke to the
OPEN Position
Gradually move the Choke
to the OPEN Position
after engine starts.
DANGER:
This Guide is not a substitute for reading the operator's manual. User must
read and understand operator's manual before using this product.