Compulevel
TM
Measurement system • 18
A pocket PC can be connected to the serial port to store, graph or
tabulate each measurement as it is taken for an unlimited number of
measurements. The position display will show (FXXX) after the
COMPULEVEL
TM
memory is full.
Press the ZERO key for two seconds to back step and clear a previous
measurement, then momentarily press and release to clear additional
measurements.
Press the REC and ZERO keys together for two seconds to clear all
measurements.
The REC DATA function can be used while in the CARRY function to record
data with each press of the HOLD key. CARRY data and normal data won’t
mix – storing one will delete all other data.
HOLD
ZERO
MARK
Saves up to 137 measurements, or an
unlimited number with pocket PC.
Take measurements over a grid of regular surface
intervals for a contour or 3D map.
One sequence can define a profile or section.
REC
DATA
Click
to record
Press
2 seconds, back space (erase)
REC
MARK
ZERO
Sample position display
To start
Press 2 seconds to start a new sequence
Press 2 seconds to enter
Press 2
seconds to
clear all data
if needed
PO
SI
TIO
NS
SE
QU
EN
CE
S