TECHNICAL DATA
FUEL:
28 Sec Kerosene
MAINS SUPPLY:
230-240V, 50Hz A.C.
I.P. PROTECTION DEGREE:
IP20
ELECTRICAL INPUT:
90 Watts
SUPPLY FUSE RATING:
3A
COOKER WEIGHT:
356 Kgs (783 lbs)
GROSS HEAT INPUT:
15.6 kW (53,355 Btu’s)
NOZZLE:
DANFOSS 0.45 60
o
ES
PRESSURE SETTING:
115 p.s.i.
CO
2
RANGE:
10.4 - 11.2%
ADDITIONAL TECHNICAL DATA FOR DHW MODELS:
MAX. DHW BOILER WORKING PRESSURE:
28 p.s.i.
TEST PRESSURE IN DHW BOILER:
40 p.s.i.
OPERATING TEMPERATURE LIMIT IN
DHW BOILER:
96
o
C (194
o
F)
DHW BOILER OUTPUT:
3.8 kW (13,000 Btu’s) (Continuous Running)
DHW BOILER CAPACITY:
10 Litres (2.2 gallons)
DHW BOILER MATERIAL:
3mm Stainless Steel
COOKER WEIGHT:
360 kg (790 lbs)
3
OPERATION
Note:
The controls are located behind the top left
hand door.
PROGRAMMABLE CONTROLLER
(MECHANICAL)
The programmer controls your cooker which allows
you to set your cooking times. It will enable you to
pre-set the times when cooking is switched ON and
OFF.
PRE-OPERATIONAL CHECKS
(a) Check that the cooker is connected to the mains
electricity.
(b) Check that the oil supply line is purged of air
and that all valves are open.
(c) Check that appliance thermostats are in the off
position.