page 16
Owner’s Manual
GX2355S
P-CH.
MEM CH.
CH. 70
MEM CH.
CH. 70
P-CH.
(When DSC scaning
is available)
(When DSC scaning
is available)
5.8
MEMORY SCANNING (M-SCAN)
NOTE
• During scanning, the dot matrix area of the LCD will show M-SCAN or
P-SCAN depending on the scan mode selected.
• The channel numbers programmed will cycle on the LCD.
• If position is displayed this icon will be hidden.
1. Adjust the
SQL
knob until background noise disappears.
2. Select a desired channel to be scanned using the
Channel
Selector
knob. Press the
MEM
key, MEM will appear on the LCD
which indicates the channel has been programmed into the
transceivers memory.
3. Repeat step 2 for all the desired channels to be scanned.
4. To DELETE a channel from the transceiver’s memory, press the
MEM
key, MEM will disappear in the LCD.
5. To start scanning, press the
SCAN
key. Scanning will proceed from
the lowest to the highest programmed channel number and will stop
on a channel when a transmission is received.
6. The channel number will blink during reception.
7. To stop scanning, press the
SCAN
,
16/9
,
WX
, or
PTT
key.
5.9
PRIORITY SCANNING (P-SCAN)
1. Any channel can be set as the priority channel, other than weather
channels and channel 70. To set the priority channel, select the
desired channel. Press and hold down the
MEM
key until P-CH is
shown on the display.
2. To select priority scanning, hold down the
SCAN
key until P-SCAN appears on the LCD
during memory scanning. Scanning will proceed
between the memorized channels and the
priority channel. The priority channel will be
scanned after each programmed channel.
BUSY HI USA
M–SCAN
VTS
A
MEM HI USA
P–SCAN CH16
A