background image

User Manual & Installation Instructions

COPYRIGHT © 2021 Reserves the right to make changes to this product without further notice.

W84A99900117-RB4

MID-COUR EV CHARGE

MC-DS 

60KW Standalone  

Fast Charger

60KW

Model

Summary of Contents for MC-DS

Page 1: ...r Manual Installation Instructions COPYRIGHT 2021 Reserves the right to make changes to this product without further notice W84A99900117 RB4 MID COUR EV CHARGE MC DS 60KW Standalone Fast Charger 60KW Model ...

Page 2: ......

Page 3: ...afety Requirement 10 3 3 Unpack the charger 12 3 4 Recommended Tools for Installation and Inspection 15 3 5 Installation Procedure 16 3 6 Installation Inspection Commissioning 22 4 Network Setting 25 4 1 Wi Fi Network Setting 25 4 2 3G 4G Setting 27 4 3 Time setting 29 5 Operation Process 31 5 1 Operating Sequence 31 5 2 Operating Procedure 31 5 3 Troubleshooting 37 5 4 Status Codes 37 6 Maintenan...

Page 4: ...harging stations charging progress and billing information The Standalone DC Fast Charger has a clear user interface with function buttons safety certifications and an excellent waterproof and dust proof design to provide the best choice for outdoor environ ments Features Pluggable power modules make installation easy and flexible Offers customers the convenience of start stop charging control from...

Page 5: ...cation 7 Information Screen Right Button Left Button RFID Card Reader Charging Status Alarm information User Authorization Emergency Stop Left DC Connector Right DC Connector The connectors installed on the EVSE may vary depending on the model section 2 2 2 ...

Page 6: ...50Vdc 950Vdc UL Model CHAdeMO 150Vdc 500Vdc UL Model GB T 150 750 Vdc Maximum Output Current CCS UL Model 120A 150Vdc 500Vdc when output voltage up to 950Vdc the output current is 63A CHAdeMO UL Model 120A 150Vdc 500Vdc GB T 120A 150Vdc 500Vdc when output voltage up to 750Vdc the output current is 80A Maximum Output Power DC 60kW Simultaneously output mode 0 50 100 Each connector will get 50 outpu...

Page 7: ... Frequency Band LTE FDD B2 B4 B5 B12 B13 B14 B66 B71 3G Frequency Band WCDMA B2 B4 B5 DLWPH 10M 4G Frequency Band LTE FDD B1 B3 B5 B7 B8 B20 LTE TDD B38 B40 B41 3G Frequency Band WCDMA B1 B5 B8 2G Frequency Band GSM B3 B8 Internal CAN RS485 Input Protection OVP OCP OPP UVP SPD Output Protection OCP OVP LVP OTP IMD Internal Protection OTP AC Contactor Detection DC Contactor Detection Fuse Detection...

Page 8: ...orage Temperature 40 C to 70 C 40 F to 158 F Relative Humidity 5 95 RH non condensing Altitude 2000m 6560 ft Regulations Safety UL2202 UL2231 EMI EMC FCC CFR Title 47 Part 15 Subpart B 2020 ANSI C63 4 2014 ICES 003 2020 Issue 7 Charging Interface CHAdeMO Ver 1 2 UL Model CCS DIN 70121 UL Model GB T 27930 Mechanical Specifications Dimensions WxDxH 700 x 331 x 1800 mm 28 x 13 x 71 inches Weight typ ...

Page 9: ...AC Connector Right DC Connector DSWx601 J00 CHAdeMO DSWx601 J0U CHAdeMO CCS1 DSWx601 U00 CCS1 DSWx601 U0U CCS1 CCS1 DSWx601 B0B GB T GB T 0 none 1 IEC 62196 2 Type 1 SAE J1772 Plug 2 IEC 62196 2 Type 1 SAE J1772 Socket 3 IEC 62196 2 Type 2 Plug 4 IEC 62196 2 Type 2 Socket 5 GB T AC Plug 6 GB T AC Socket 7 CCS2 AC Plug B GBT DC PT1000 J CHAdeMO U Natural cooling CCS1 combo V Liquid cooling CCS1 com...

Page 10: ...Indication and Operation Status Left Indicator Right Indicator Standby Green Green Fault Red Red Charging Blue Blue Status LED Standby Fault Charging Left LED for Left Connector Right LED for Right Connector 7 ...

Page 11: ...2 5 Direction of cooling Airflow Air Out Air In 2 4 Dimensions Main Size of Charger Unit mm 700 331 1800 8 ...

Page 12: ...and the PE of the power distribu tion are directly connected to the earth The PE of the charger equipment is iso lated to the PE of power distribution to the earth The capacity of power supply should be higher than 67kVA in order to function correctly The product should be installed in free air area and keep at least 30cm 12 inch es clearance distance to all air vent of the product Recommend to ke...

Page 13: ...afety Requirement CAUTION The disconnect switch for each ungrounded conductor of AC input shall be provided by installation contractor or technician in accordance with the National Electric Code ANSI NFPA 70 CAUTION A cord extension set or second cable assembly shall not be used in addition to the cable assembly for connection of the EV to the EVSE NOTICE It is recommended to conduct WI Fi and 4G ...

Page 14: ...he main breaker panel and Neutral connected to Ground at that point 480Vac Line to Line Three Phase CAUTION This is feed from Wye connection power grid the Standalone DC Fast Charger can connect to L1 L2 or L3 and Neutral Earth ground must be connected to neutral at only one point usually at the breaker panel 480V Three Phase Wiring Connection WARNING Earth Connection is Essential PE 277V 277V 277...

Page 15: ... its final location last mile service is not standard included in the order 3 NOTICE The delivery truck unloads the pallet carrying the charger The move ment of the charger to its final location is the responsibility of the customer contractor If the TiltWatch indicator is red tilted over 80 1 Do not refuse the shipment receipt 2 Make a notation on the delivery receipt and inspect cabinet for damage...

Page 16: ...Remove the surrounding boards STEP 1 STEP 2 Remove the carton and packing cushion and film 13 ...

Page 17: ...ove these 4 pcs of fixing M12 screws STEP 3 To use lifting eye bolts to move the EVSE please apply 6mm 1 4 inches di ameter steel wire rope to the four eye bolts as following picture STEP 4 6 0 0 m m 2 4 14 ...

Page 18: ...erminal for L1 L2 L3 N Inner Diameter 10 5mm 0 41 Outer Diameter 22mm 0 87 2 Ring Terminal for PE Inner Diameter 6 4mm 0 25 Outer Diameter 22mm 0 87 Crimping Pliers for Ring Terminal Wire Stripper Wire Cutters Crane Forklift 235 kg 518 lbs 3 4 2 Recommended Tools for Inspection Commissioning Type Description EV or EV Simulator Meet CHAdeMO CCS Standard Multiple Meter 1000V Current Probe 200Amp RFI...

Page 19: ... x H 700 x 331 x 1800 mm 27 6x13 0x315 4 inch Front side 600 mm 23 6 inch in order to operate dashboard Left and right side 350 mm 13 8 inch in order to open left and right door Backside 600 mm 23 6 inch in order to open the bracket door 3 5 1 Required space for placing and maintaining 23 6 23 6 13 8 55 1 13 8 27 6 13 0 13 8 1531 16 ...

Page 20: ...hin 2 mm 0 08 in short axis 8 mm 0 32 in long axis according to screw holes of charger 4 To fit this positioning requirement a steel plate fixture be suggested Please create the fixture by the following drawing or order this fixture from your ven dor 5 The other way to fix the charger on concrete base is install 2 of L brackets accessories outside of charger and drill the screw holes Φ12 mm 0 47 on the...

Page 21: ...ter 6 4mm 0 25 Outer Diameter 22mm 0 87 The conductor cross sectional area of input power wires should be not less than 53 5mm 106 kcmil If internet is connected via Ethernet at least 1800mm 71 of the Ethernet cable must be exposed from the conduit STEP 2 AC Cable at least 400mm 15 75 inches Ethernet cable 1800mm 71 inches For AC cable conduit For Ethernet cable conduit L Bracket orifice screw sti...

Page 22: ...s of M12 washers on 4 pcs of M12 screw of concrete base 2 nuts for each screw to secure the chargers Then fix the base cover in the accessory pack in charger base METHOD 1 3 5 3 Two Methods of Fixing DSWx601 Charger If use L brackets to fix charger secure L brackets on the cement base by 4 pcs of M12 expansion bolts METHOD 2 19 ...

Page 23: ...cessory pack STEP 1 3 5 4 Installing Cables Open Right Cover for Wiring Connect L1 L2 L3 and N of AC power to 4P termi nal Fasten each wire with proper screw and torque number 120Kgf cm 5 15 secs Connect the PE wire green with yellow to grounding position of charger and torque number 60Kgf cm L1 L2 L3 N PE 20 ...

Page 24: ...eaker Recom mended breaker spec Max input current shall be over than or equal to 150A B Curve type STEP 3 Not following installation instruction will cause charger damage An breaker over than or equal to 150A NFB B curve Do Inspection as section 3 6 1 to 3 6 3 Turn on the power source and be ready for operational testing The power supply of the Standalone DC Fast Charger will be enabled and automa...

Page 25: ...60 ft Air Circulation Drafty Dust Level Anti Vandalism Measures 3 6 2 External Infrastructure Readiness Check Item Status Remark Input Wirings Terminals Type Length Cross Section Key Lock of Cabinet Door Fixing Screws Type No No Fuse Breaker NFB Notice Current rating of NFB shall be higher than 134 Amp Input Electricity Capacity Input Electricity Configuration Wye Grounding Resistance 10 Ω Groundin...

Page 26: ... 6 1 Screw torque requirement table 3 6 4 Check Power On Item Status Remark Screen On Acoustic Noise Screen Display Function Time Display Correctly Network Connection Quality Cooling Fans Operation Noise Led Status Indication EVSE Setting Function of Engineer Mode Version of H W F W Remote Control Monitoring Backend Server Connection Wi Fi 4G 65dBm 23 ...

Page 27: ...atus Remark User Authorization RFID User Authorization QR Code User Authorization Others Waiting Time of Connection Check Reading of Each Display Item Full Charge Test Function of Electronic Lock Reading of Engineer Mode Airflow Noise of Cooling Fan Charging Record log Upload Remote Control Monitoring 24 ...

Page 28: ...Account Password login https 192 168 1 10 admin 1231231238 192 168 1 10 SET UPGRADE OTHER LANGUAGE System System Charging Network Backend SET Network Open web service browser type the IP address of charger 192 168 1 10 into the URL bar to access the web page of charger Account admin Password 1231231238 Use the following IP address IP address 192 168 1 1 Subnet mask 255 255 255 0 Default gateway St...

Page 29: ...Mode WiFI Module WiFiSsid WiFiPassword Set Step 4 Select Wi Fi Module Select Wi Fi modes and fill in SSID and Password according to your application if not required just keep default WARNING Due to the different environmental conditions it is recom mended to conduct Wi Fi and 4G module network signal tests before installation The RSSI Received Signal Strength Indication value suggest to be higher t...

Page 30: ...ide the cabinet Step 1 4 2 1 SIM Card Installation Insert 3G 4G Micro SIM Card in the tray ensure the gold contacts are facing down and the notch is located in the upper right corner Note the tray might be damaged if insert SIM card in wrong direction Step 2 SIM Card SIM Card 27 ...

Page 31: ...GRADE OTHER LANGUAGE TelcomApn 3G 4G Module TelcomChapPapId TelcomChapPapPwd Set 4 2 2 Setting and Enable 3G 4G Module Network 3G 4G Module to fill corresponding information into TelcomApn TelcomChapPa pid and TelcomChapPapPwd Press Set to save those information Then 3G 4G will be activated in few minutes 192 168 1 10 Network Network Status Ethernet WiFi 3G 4G Step 3 192 168 1 10 Account Password l...

Page 32: ...nce the time server connection Manual setting Laptop with RJ45 interface Connect RJ45 cable from Laptop to charger s RJ45 port Setup parameters in the Webservice Step 1 Before opening web browser please enter network setting to set your IPV4 static IP to 192 168 1 1 in PC Open web service browser type the IP address of charger 192 168 1 10 into the URL bar to access the web page of charger Account...

Page 33: ...g completion window ap pears 192 168 1 10 SET UPGRADE OTHER LANGUAGE System System Charging Network Backend 192 168 1 10 System System Information Version Information 192 168 1 10 XXXX XX XX XX XX XX System Information System DateTime XXXX XX XX XX XX XX System 192 168 1 10 System Set XXXX XX XX XX XX XX System Information System DateTime XXXX XX XX XX XX XX Step 4 Step 5 Step 6 Step 7 30 ...

Page 34: ... Messages 5 1 Operating Sequence When the charger is powered on it start with the Charging Station Initializing page You will see the below image on the screen after powering on and the system is initializing The initializing process will take around 2 minutes then shows home page 5 2 Operating Procedure 5 2 1 System Initialization Initializing page 31 ...

Page 35: ...on User authorization Method RFID QR code and mobile APP Unauthorized method s will be darker on the screen if the method is disable Home page 3G 4G Status Wi Fi Status Unit and currency if billing function is enabled Ethernet Backend Status Home page Connection Dis Connection Connection Dis Connection Connection Dis Connection OCPP Backend Status Connection Dis Connection 32 ...

Page 36: ... type of the charging connector It will normally take less than 10 seconds to start the process after completing the physical connection of charging connector to charging inlet To terminate this session please press the left button to return to the Home page Press left button to terminate this charging session and then return to Home page Plug in page The left connector will always have the chargi...

Page 37: ...reen will show the Charging Page as below illustrated once the charger goes into the ready to charge stage 5 2 5 In Charging Charging information area EV battery SOC Show the selected connector in use Information of Selected Charging Connector Connector Select Button Preparing page Charging duration Charged power Energy Press right button to select the char ger connector that the user would like t...

Page 38: ...ger connector that the user would like to stop User also can tap the RFID to stop charging To start charging load the charging information When the battery has been fully charged or reaches the limit of the setting it will stop charging automatically and go to the next process 35 ...

Page 39: ...er charging connec tor s Charging Page if unplugged from the charging connector During simultaneous charging the screen will go to the other charging connector s Charging Page if either charging connector is unplugged 5 2 6 Charging Terminated Charging energy Charging duration Charging power When problems occur with this charger or the charging process a status code will display on screen as below...

Page 40: ... Code Description 011001 CHAdeMO output fuse blew 011002 CCS output fuse blew 011003 GB output fuse blew 011004 RCD CCID self test fail 011005 AC input contactor 1 welding 011006 AC input contactor 1 driving fault 011007 AC input contactor 2 welding 011008 AC input contactor 2 driving fault 011009 AC output relay welding 011010 AC output relay driving fault 011011 CHAdeMO output relay welding 0110...

Page 41: ...CD CCID module broken 011033 Maximum Output Current setup error 011034 Shutter fault 011035 Ble module broken 011036 Rotary switch fault 011037 CCS liquid chiller water level fault 011038 Chiller temperature sensor broken 011039 Reserved 011040 Reserved 012200 System L1 input OVP 012201 System L2 input OVP 012202 System L3 input OVP 012203 System L1 input UVP 012204 System L2 input UVP 012205 Syst...

Page 42: ...ritical point OTP 012225 PSU ambient inlet OTP 012226 PSU critical point OTP 012227 Aux power module OTP 012228 Relay board smart box OTP 012229 CHAdeMO connector OTP 012230 CCS connector OTP 012231 GB connector OTP 012232 AC connector OTP 012233 RCD CCID trip 012234 CHAdeMO GFD trip 012235 CCS GFD trip 012236 GB GFD trip 012237 SPD trip 012238 Main power breaker trip 012239 Aux power breaker trip...

Page 43: ...2256 AC Ground Fault 012257 MCU self test Fault 012258 Relay self test Fault 012259 CHAdeMO groundfault detection timeout GFD 012260 CCS groundfault detection timeout GFD 012261 GB groundfault detection timeout GFD 012262 System AC L1 output Circuit Short 012263 PSU Duplicate ID 012264 PSU Output Short Circuit 012265 PSU Discharge Abnormal 012266 PSU Dc Side ShutDown 012267 PSU Failure Alarm 01226...

Page 44: ...est Failed due to Model name is none match 012288 CCS output UVP 012289 Chademo output UVP 012290 GBT output UVP 012291 Self test Failed due to communication of GBTboard failure 012292 Self test Failed due to communication of AC failure 012293 Self test Failed due to communication of Ledboard failure 012294 AC input ovp 012295 AC input uvp 012296 CHAdeMO groundfault detection warning 012297 CCS gr...

Page 45: ...P 012322 System GBT output UCP 012323 System Chiller output OTP 012324 Connector 1 detects abnormal voltage on the output line 012325 Connector 2 detects abnormal voltage on the output line 012326 System task is lost 012327 DC input ovp 012328 DC input uvp 012344 Meter IC communication timeout 012345 Pilot negative error 013600 Normal stop charging by user 013601 Charging Time s up 013602 Replace ...

Page 46: ...backend 013621 configured by webage 013622 disconnected from Internet through Ethernet 013623 disconnected from Internet through WiFi 013624 disconnected from Internet through 3G 4G 013625 disconnected from AP through WiFi 013626 disconnected from APN through 3G 4G 013627 WiFi disabled separated charger only 013628 4G disabled separated charger only 013629 Reserved 013630 Reserved 013631 Reserved ...

Page 47: ...rent timeout 023724 CHAdeMO bms k to j off timeout 023725 CHAdeMO bms ev relay off timeout 023726 CHAdeMO adc more than 10v 023727 CHAdeMO adc more than 20v 023728 CHAdeMO bms charge before stop 023729 CHAdeMO charger get normal stop cmd 023730 CHAdeMO charger get emergency stop cmd 023731 CHAdeMO isolation result fail 023732 CHAdeMO mother board miss link 023733 CHAdeMO output voltage more than l...

Page 48: ...CC_EVErrorCode_FAILED_reserved_by_OEM_3 023756 CCS_EVCC_EVErrorCode_FAILED_reserved_by_OEM_4 023757 CCS_EVCC_EVErrorCode_FAILED_reserved_by_OEM_5 023758 CCS_SECC_ResponseCode_FAILED_SequenceError 023759 CCS_SECC_ResponseCode_FAILED_SignatureError 023760 CCS_SECC_ResponseCode_FAILED_UnknownSession 023761 CCS_SECC_ResponseCode_FAILED_ServiceIDInvalid 023762 CCS_SECC_ResponseCode_FAILED_Payment Selec...

Page 49: ...LED_GAChargeStop 023785 CCS_SECC_ResponseCode_FAILED_AlignmentError 023786 CCS_SECC_ResponseCode_FAILED_ACDError 023787 CCS_SECC_ResponseCode_FAILED_AssociationError 023788 CCS_SECC_ResponseCode_FAILED_EVSEChargeAbort 023789 CCS_SECC_ResponseCode_FAILED_NoSupportedApp Protocol 023790 CCS_SECC_ResponseCode_FAILED_ContractNotAccepted 023791 CCS_SECC_ResponseCode_FAILED_MOUnknown 023792 CCS_SECC_Resp...

Page 50: ...D 023812 CCS_SECC_TIMEOUT_SLAC_TT_EVSE_match_MNBC 023813 CCS_SECC_TIMEOUT_SLAC_TP_EVSE_avg_atten_calc 023814 CCS_SECC_TIMEOUT_SLAC_CM_ATTEN_CHAR_RSP 023815 CCS_SECC_TIMEOUT_SLAC_CM_VALIDATE_REQ_1ST__CM_SLAC_ MATCH_REQ 023816 CCS_SECC_TIMEOUT_SLAC_TT_EVSE_assoc_session 023817 CCS_SECC_TIMEOUT_SLAC_TT_EVSE_vald_toggle 023818 CCS_SECC_TIMEOUT_SLAC_CM_MNBC_SOUND_IND 023819 CCS_SECC_TIMEOUT_SLAC_CM_VAL...

Page 51: ...iscoveryRes 023838 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_PowerDeliv eryRes 023839 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_CableCheck Res 023840 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_Pre ChargeRes 023841 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_CurrentDe mandRes 023842 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_WeldingDe tectionRes 023843 CCS_SECC_TIMEOUT_V2G_Msg_Performance_Time_SessionS...

Page 52: ...AN_TIMEOUT_TT_GET_MISC_INFO 023865 CCS_CAN_TIMEOUT_TP_DOWNLOAD_REQUEST 023866 CCS_CAN_TIMEOUT_TT_DOWNLOAD_REQUEST 023867 CCS_CAN_TIMEOUT_TP_START_BLOCK_TRANSFER 023868 CCS_CAN_TIMEOUT_TT_START_BLOCK_TRANSFER 023869 CCS_CAN_TIMEOUT_TP_DATA_TRANSFER 023870 CCS_CAN_TIMEOUT_TT_DATA_TRANSFER 023871 CCS_CAN_TIMEOUT_TP_DOWNLOAD_FINISH 023872 CCS_CAN_TIMEOUT_TT_DOWNLOAD_FINISH 023873 CCS_CAN_TIMEOUT_TP_IS...

Page 53: ...7000 may not be installed yet 023893 CCS_SECC_FAIL_QCA7000_SETKEY 023894 Reserved 023895 Reserved 023896 Reserved 023897 Reserved 023898 Reserved 023899 Reserved 023900 GBT_LOS_CC1 023901 GBT_CONNECTOR_LOCK_FAIL 023902 GBT_BATTERY_INCOMPATIBLE 023903 GBT_BMS_BROAA_TIMEOUT 023904 GBT_CSU_PRECHARGE_TIMEOUT 023905 GBT_BMS_PRESENT_VOLTAGE_FAULT 023906 GBT_BMS_VOLTAGE_OVER_RANGE 023907 GBT_BSM_CHARGE_A...

Page 54: ... Reserved 023925 Reserved 023926 Reserved 023927 Reserved 023928 Reserved 023929 Reserved 023930 GBT_CEM_BHM_TIMEOUT 023931 GBT_CEM_BRM_TIMEOUT 023932 GBT_CEM_BCP_TIMEOUT 023933 GBT_CEM_BRO_TIMEOUT 023934 GBT_CEM_BCL_TIMEOUT 023935 GBT_CEM_BCS_TIMEOUT 023936 GBT_CEM_BSM_TIMEOUT 023937 GBT_CEM_BST_TIMEOUT 023938 GBT_CEM_BSD_TIMEOUT 023939 GBT_CEM_BEM_OTHER_TIMEOUT 023940 GBT_BEM_CRM_TIMEOUT 023941 ...

Page 55: ...BST_COMPONEN 023957 GBT_BST_CHARGE_CONNECTOR 023958 GBT_BST_OTP 023959 GBT_BST_OTHER 023960 GBT_BST_HIGH_V 023961 GBT_BST_CC2 023962 GBT_BST_CURRENT 023963 GBT_BST_VOLTAGE 023964 GBT_GET_BST_NO_REASON 023965 Reserved 023966 Reserved 023967 Reserved 023968 Reserved 023969 Reserved 023970 GBT_BSM_CELL_OVER_VOLTAGE 023971 GBT_BSM_CELL_UNDER_VOLTAGE 023972 GBT_BSM_OVER_SOC 023973 GBT_BSM_UNDER_SOC 023...

Page 56: ...rging by backend 033905 Remote reset by backend 033906 Reserved 033907 Reserved 041004 RCD CCID self test fail 041005 AC input contactor 1 welding 041006 AC input contactor 1 driving fault 041007 AC input contactor 2 welding 041008 AC input contactor 2 driving fault 041009 AC output relay welding 041010 AC output relay driving fault 041017 AC connector temperature sensor broken 041021 WiFi module ...

Page 57: ...L1 input drop 042213 System L2 input drop 042214 System L3 input drop 042223 System ambient inlet OTP 042224 System critical point OTP 042225 PSU ambient inlet OTP 042226 PSU critical point OTP 042227 Aux power module OTP 042228 Relay board smart box OTP 042232 AC connector OTP 042233 RCD CCID trip 042237 SPD trip 042238 Main power breaker trip 042239 Aux power breaker trip 042240 PSU communicatio...

Page 58: ...SU FanFailure Alarm 042270 PSU Input UVP 042271 PSU Input OVP 042272 PSU WalkIn State 042273 PSU Power Limited State 042274 PSU Id Repeat 042275 PSU Severe Uneven Current 042276 PSU Three Phase Input Inadequate 042277 PSU Three Phase Onput Imbalance 042278 PSU Ffc Side ShutDown 042279 NO PSU Resource 042280 Self test Failed due to communication of Relayboard failure 042281 Self test Failed due to ...

Page 59: ...2 System AC L3 output Circuit Short 042304 disconnected from dispenser 042305 Meter communication timeout 042306 The dip switch of the PSU may be incorrect 042307 Psu Fuse Burn Out 042308 Psu Pfc And Dcdc Communication Fault 042309 Psu Bus Voltage Unbalance 042310 Psu Bus Over Voltage 042311 Psu Bus Voltage Abnormal 042312 Psu Bus Under Voltage 042313 Psu Input Phase Loss 042314 Psu Fan Full Speed...

Page 60: ... update fail 043617 SMR fimrware update fail 043618 RFID module fimrware update fail 043619 configured by USB flash drive 043620 configured by backend 043621 configured by webage 043622 disconnected from Internet through Ethernet 043623 disconnected from Internet through WiFi 043624 disconnected from Internet through 3G 4G 043625 disconnected from AP through WiFi 043626 disconnected from APN throu...

Page 61: ...ng painting surface bright ness and durability of all exterior parts If there is water intruding into the DC Fast Charger then please cut off the power source immediately and contact the DC Fast Charger provider for repair Please make sure the charging connector is returned to the holder of the charging connector after charging to prevent damage If there is damage to the charging connector chargin...

Page 62: ...ny maintenance work Replace the ventilation filter every six to twelve months Please confirm the main power junctions are tightened every month and ro tate cables testing when the power off If any main power screw is loose will be resulted in damage on charger or smoke on the connections Please confirm screw torque requirement table Charging cable maintenance Do not twist bend the charging cable Th...

Page 63: ...16 23 24 30 98 190 253 18 63 24 8 M10 1 5 Hex cap 212 382 245 440 24 02 43 15 196 351 19 22 34 42 M12 1 75 Hex cap 372 668 430 770 42 17 75 49 343 615 33 63 60 3 Screw in Imperial 2 56 Machine 1 5 2 1 7 2 3 0 17 0 22 1 4 1 8 0 14 0 18 4 40 Machine 3 4 3 5 4 5 0 34 0 44 2 8 3 6 0 27 0 35 6 32 Machine 6 10 7 11 5 0 68 1 13 5 6 9 2 0 55 0 9 8 32 Machine 10 15 11 5 17 1 13 1 66 9 2 14 0 9 1 37 10 32 M...

Page 64: ...mp or above DC charging connector 4M charging cable Charging Cable Holder Emergency Stop Button 30kW DC PSU U 1K0100 MW Aux Power HEP 100 12V MW Aux Power HEP 600 24V Control Supervisory Unit CSU3 0 Surge Protection Device SPD DC Fan Air Filters Door Key Gland M50 User Manual Relay board Fan board LED board 4G Wi Fi board DC Relay AC Contactor NFB 61 ...

Page 65: ...product or other event beyond Supplier s reasonable control or not arising from normal operating condition Cosmetic or superficial defect dents marks or scratches after use Components which are separate from the product ancillary equipment and consumables such as door key RFID card air filter fuse cable wires and con nectors Damage as a result of modifications alterations or disassembling which were ...

Page 66: ... customer whichever is longer In order to receive the remedy set for above you must contact Supplier during the warranty period and provide the model number series number proof of purchase and date of purchase This warranty does not cover the damages caused by adapter usage accident or by other unauthorized operation service 63 ...

Page 67: ...iption No Remark 1 EVSE 1 2 User Manual 1 3 EVSE Approved Certificate 1 4 OQC Report 1 5 RFID Card 2 6 Door Key 1 7 Waterproof Plastic Bolts 4 8 Base Cover 2 A Cable Management 1 Optional B Bracket set for payment system 1 Optional 64 ...