4.2 Protection Degree  

 

 

  IP 44: The appliance features a protection against solid objects having a size exceeding  

 

  1 mm and protection against splashes of water (splashes of water from any direction on  

 

  the cover  must not produce dangerous effects). 

 

IP 20: Apparatus protected against solid parts larger than 12 mm but not protected against   

 

the infiltration of water.

4.3 Electrical insulation degree  

 

CLASS I: The appliance features basic electrical insulation.

 

Must be connected to the ground circuit through the main electric circuit.

 

CLASS II: The appliance features double electrical insulation. They doesn’t need a connetion   

 

to the ground circuit through the main electric circuit.

4.4 Declaration of absence of dangerous substances

The manufacturer declares that its products and appliances have been manufactured with materials 
which comply with the restrictions established by the health and environment protection regulations in 
force and do not contain SVHC-classified  substances (Substance of Very High Concern) in compliance 
with CE regulation 1907/2006 (REACH: i.e. Registration, Evaluation, Authorization and Restriction of 
Chemical Substances). Although these substances have not been used during the processing cycles of 
raw materials and during the manufacturing cycles of our products, their presence in p.p.m. (parts per 
million) cannot be completely excluded due to micro-pollution of raw materials.

4.5 Fixed closure guards safety

The vacuum cleaner is delivered to the Customer with its main body completely assembled. Moving parts 
(suction motor turbine blades) are protected by a protection grid directly assembled on the inlet of the 
suction motor compartment. This protection grid cannot be accessed by the operator. The operator also 
does not have access to the electrically-operated parts of the appliance which are protected by a cover 
which can only be removed by unscrewing  the Torsen screws used to fix the soundproofing dome of the 

housing where the suction motors are assembled.

Every intervention on the control board and on the motors must be carried out by qualified personnel only 
after disconnecting the electrical power supply and by removing the electric plug from the electric socke

4.6 Movable closure guards safety 

There are no movable closure guards assembled on the appliance. Every guard assembled is conside

-

red a fixed guard and is fastened with special screws. The manufacturer reminds you that it is absolutely 
forbidden to replace the screws used for the design and manufacture of the appliances with screws that 

feature different characteristics. 

The manufacturer will immediately suspend the product guarantee in case of machine tampering carried 

out by the Customer. 

IP20

Summary of Contents for Vacu PRO

Page 1: ...ENG Installation Use and Maintenance Instructions Central Vacuum Unit Vacu PRO ...

Page 2: ......

Page 3: ...ble closure guards safety 8 4 7 Identification plate 9 5 PACKAGE CONTENTS 10 6 INSTALLATION 11 6 1 Preliminary operations 11 6 2 Place of installation 11 6 3 Fixing the vacuum cleaner to the wall 12 6 4 Connection to the piping network 13 6 5 Electrical connection 15 6 6 Using the service socket 16 7 MAINTENANCE 16 7 1 Programmed routine maintenance 16 7 2 Cleaning the suction container cylinder 1...

Page 4: ...o VACU PRO 2330 2340 Suction coupling Ø mm 50 50 Air exhaust Ø mm 50 50 IP Protection Degree IP 20 20 Power supply V ac 220 230 220 230 Frequency Hz 50 60 50 60 Motor power kW 1 8 1 9 Absorption A 7 9 8 2 Socket power supply V dc 12 12 Maximum air flow m3 h 240 257 Dust bin capacity l 25 25 Air venting YES YES Air exhaust silencer YES YES Weight kg 10 5 10 5 Sound level dB A 70 346 120 112 177 153...

Page 5: ...5 2 27 04 2022 Rev 1 0 0 English Main switch Thermal switch Air exhaust ON OFF switch service inlet Service vacum inlet Closing handle and hook Dust bin Dust inlet 1 2 3 4 6 7 8 5 ...

Page 6: ...Do not suction cement flour or similar materials including the construction site dust lime remains plaster powder and so on which may cause the reduction of the vacuumed air with a consequent da mage of the motor The system has not been designed to be used in environments with risk of explosion and the refore it is forbidden to vacuum clean materials with high explosion risk gunpowder or materials...

Page 7: ...on Children should not play with the ma chine nor with the suction sockets This equipment should not be used by people including children with reduced psychic sensory or mental capacities or by people with no experience nor knowledge of the system unless they are under the guidance or instructed to use the machine by people responsible for their safety Children must always be supervised to ensure ...

Page 8: ...als and during the manufacturing cycles of our products their presence in p p m parts per million cannot be completely excluded due to micro pollution of raw materials 4 5 Fixed closure guards safety The vacuum cleaner is delivered to the Customer with its main body completely assembled Moving parts suction motor turbine blades are protected by a protection grid directly assembled on the inlet of ...

Page 9: ...cation plate is assembled on the side of the connection to the piping network This should not be removed or damaged IP20 Model P N S N Manufacturer Identification Technical data of the electric motor Serial Number Type of Central vacuum cleaner Article CE conformity marking ...

Page 10: ... the accessory kit consisting of the following parts 1 N 1 wall mounting bracket for fixing the central vacuum unit to the wall 2 N 1 rubber sleeves for connection to the vacuum pipe network 3 N 3 metal clamps for fixing the sleeves 4 N 1 installation use and maintenance manual 5 N 1 plastic air exhaust silencer for air discharge 1 2 3 4 5 MANUALE TECNIC O S l ...

Page 11: ...uction piping network installed by qualified personnel who has already selected the most suitable location Below you will find the main indications to be followed for a correct installation If the appliance will be connected to a pipe network on more than one floor we suggest you to install it in the lowest part of the building Install the system in service rooms e g garage or storage room away fr...

Page 12: ...ht times the weight of the system itself The system should be positioned high enough off the ground to allow the dust collection bin to be emptied and the filter to be replaced in a simple way Position the system so as to keep a minimum distance of 60 cm around the appliance for extraordinary maintenance To do this follow the instructions detailed below 2 1 Drill the holes Tighten the screws in th...

Page 13: ...sleeve connect the dust inlet coupling of the cyclonic vacuum cleaner identified with C in the picture to the suction pipe from the piping network 3 By using the sleeve connect the air outlet of the central vacuum unit marked with D to the air outlet of the house 4 Glue the silencer E on the exhaust pipe near the exhaust air grid N B do not glue the pipe end of the network pipe to the dust inlet c...

Page 14: ...uld it be necessary to convey the air discharge to the outside please follow the following instructions Maximum length of the discharge pipe N B Diameter of the outlet pipe for a length up to 10 m 50 mm Exhaust pipe diameter for lengths over 10 m 63 mm ...

Page 15: ...mages to people and or objects due to the connec tion to a non complying electric wiring Follow the instructions see picture detailed below to carry out the operation Connect the input signal cable MICRO LINE to the suction sockets Insert the plug of the power supply cable from the central system in the electric socket Check that the electrical wiring of the house has been set up in compliance wit...

Page 16: ... entail damages Ensure the system s surface is completely dry before switching it back on Always use a suitable mask to protect against airborne dust and wear latex gloves to protect your hand skin BEFORE CARRYING OUT ANY MAINTENANCE OPERATION IT IS MANDATORY TO UNPLUG THE POWER SUPPLY CABLE FROM THE POWER SUPPLY INLET PROTECTIVE MASK AND GLOVES MUST ABSOLUTELY BE WORN Working time h Maintenance E...

Page 17: ... back in position 4 Reassemble the dust bin inside its housing under the suction system and lock the closing handles Switch the suction system on by pressing the ON OFF switch Remember to be careful when emptying the bin if there is a big quantity of dust make sure you do not throw away the conveyor cone Always check that the conveyor cone is still in place and correctly assembled in its housing i...

Page 18: ...or repairs and or maintenance which are not expressly authorized in this manual is absolutely forbidden Any repair for breakage or malfunctioning must be carried out by qualified Technical Assistance personnel Any intervention of non authorized personnel will result in the invalidation of any guarantee of the product and the manufacturer will not be held responsible for any eventual damage to pers...

Page 19: ...service suction socket is working Use only one suction inlet at a time The flexible hose or the cleaning accessories are broken Check the flexible hose and the accessories are not damaged change them if necessary The filter cartridge is dirty Clean the filter cartridge The sealing gasket of the dust bin is damaged Check sealing gasket integrity There is a clogging in the suction pipes of the pipe ...

Page 20: ...F0920620 36031 Dueville VI ITALIA Via Prati 11 Tel 39 0444 1803418 info stakorr it ...

Reviews: