background image

When setting channel 1, the following channels are automatically addressed consec‐

utively. This addressing may be adjusted as described above.

The unit is operational as soon as power is applied. The activation is done automatically in

‘Power on’

 mode and in 

‘Manual’

 mode using the 

[Standby]

 button.

Proceed as follows to adjust the Switch mode:
1.

Open the menu 

‘Unit Setup’

‘PowerOn’

 (see menu overview).

2.

Confirm with the 

[Menu]

 button.

ð

The current setting appears on the display.

3.

Select the desired Switch-on mode with the navigation buttons   or  .

4.

Press the 

[Menu]

 button.

ð

The display shows the confirmation prompt 

‘Save Changes?’

.

5.

Confirm the prompt with 

[Menu]

 to save the new settings. To discard the changes, press

the navigation button   to return to the previous menu level.

Switch mode

Operating

 

 

D1210T

27

Summary of Contents for D1210T

Page 1: ...D1210T dimmerpack user manual...

Page 2: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 24 06 2014 ID 327878...

Page 3: ...ions 6 1 3 Symbols and signal words 6 2 Safety instructions 8 3 Features 12 4 Installation and starting up 13 5 Connections and operating elements 16 6 Operating 20 7 Technical specifications 31 8 Plu...

Page 4: ...ons and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this...

Page 5: ...word search Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms...

Page 6: ...kets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF 1 3 Symbols and signal words In this section y...

Page 7: ...l result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damag...

Page 8: ...physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsib...

Page 9: ...cable ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified elec trica...

Page 10: ...any direct heat source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid or...

Page 11: ...and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms...

Page 12: ...heat dimmer curve and maximum voltage can be adjusted individually n Indicators for temperature and operation n Test function n Intelligent cooling control large cooling ribs n Single channel fuse 10...

Page 13: ...rotect the device against vibration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Establis...

Page 14: ...k to the controller Finally connect the device via the 3 phase screw terminal block to the power supply Connection options for blocks L1 L2 and L3 n one block per phase n one block to one phase two bl...

Page 15: ...r DMX device Connect the output of the first DMX device to the input of the second and so on to form a series connection Make sure that the output of the last DMX device in the chain is ter minated by...

Page 16: ...5 Connections and operating elements Front panel Connections and operating elements dimmerpack 16...

Page 17: ...deactivated O OFF 2 L1 L3 Voltage indicators of blocks L1 L3 The LEDs of the connected blocks light red as soon as mains power is applied to the device 3 1 12 Voltage indicators of channels 1 12 The...

Page 18: ...6 Menu Button to open the main menu and confirm display values 7 Navigation buttons Buttons to navigate the device menu Connections and operating elements dimmerpack 18...

Page 19: ...mmer outputs 4 screw terminal blocks note the device label when connecting the cables 9 Fan 10 Power connector screw terminals 3 phase 32 A 3 230 V Rear panel Connections and operating elements D1210T...

Page 20: ...Press Menu to switch from standby to normal operation Turn on the required channels via the associated circuit breakers LEDs of active channels light up green Use the navigation button to return to s...

Page 21: ...ed loads Hence there is danger to life and the risk of damage to property when connecting and disconnecting loads as well as during maintenance Disconnect the power plug from the CEE mains socket befo...

Page 22: ...Menu overview Operating dimmerpack 22...

Page 23: ...s 3 Select the desired channel with the navigation buttons or 4 Use the navigation button to change to the curve value The displayed value flashes 5 Select the desired setting with the navigation butt...

Page 24: ...er display flashes 3 Select the desired channel with the navigation buttons or 4 Use the navigation button to change to the voltage value The displayed value flashes 5 Adjust the value using the navig...

Page 25: ...isplay flashes 3 Select the desired channel with the navigation buttons or 4 Use the navigation button to change to the preheat value The displayed value flashes 5 Adjust the value using the navigatio...

Page 26: ...uttons or 4 Use the navigation button to change to the set DMX address The displayed value flashes 5 Adjust the value using the navigation buttons or 6 Press the Menu button The display shows the conf...

Page 27: ...oceed as follows to adjust the Switch mode 1 Open the menu Unit Setup PowerOn see menu overview 2 Confirm with the Menu button The current setting appears on the display 3 Select the desired Switch on...

Page 28: ...isplay flashes 3 Select the desired channel with the navigation buttons or 4 Change with the navigation buttons and between channel number and channel value 5 Press the Menu button to exit Test mode T...

Page 29: ...ndividual blocks see menu overview Select the desired block with the navigation buttons or Above a temperature of 45 C the internal fans will be switched on The fan power will be increased continuousl...

Page 30: ...Signal see menu overview When the signal is received correctly the display will show DMX Signal OK On a faulty signal No DMX Signal appears In this case check the connecting cables and DMX settings o...

Page 31: ...connection Three phase connection max 32 A per phase Channel fuse 1 circuit breaker per channel 10 A C characteristic Signal input DMX 512 via 3 pin XLR socket Outputs 4 screw terminal blocks Dimensio...

Page 32: ...to a socket the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR p...

Page 33: ...ng Please follow the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household wast...

Page 34: ...Notes dimmerpack 34...

Page 35: ......

Page 36: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...

Reviews: