Mounting and installation
20
283923 / YL6S60300070
2021-10-27·BA00·III·en·00
DE
EN
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
Audible and visual signalling device
Series YL6S/2
7.3.2 Electrical connections
• Lay the pre-installed cabling in the intended electrical connections – see figure.
DANGER
Explosion hazard due to insufficient protective measures!
Non-compliance results in severe or fatal injuries.
• Select suitable conductors to ensure that the maximum permissible
conductor temperatures are not exceeded.
• When using core end sleeves, attach them using a suitable tool.
• The conductor insulation must be touching the terminal.
• Do not damage the conductor (e.g. nicking) when stripping it.
• Finally, check the conductor to ensure that it is secure (fixed).
22503E00
22504E00
9
Control (A/B signal)
11
Audible signal power supply
10
Visual signal power supply
11
10
9
B A
Sounder LED
0V 24V 0V 24V
9
11
10