Mounting and installation
18
283923 / YL6S60300070
2021-10-27·BA00·III·en·00
DE
EN
FR
IT
ES
RU
NL
DK
SE
FI
PT
GR
PL
CZ
SK
HU
SL
RO
BG
LV
LT
EE
CH
KR
CN
Audible and visual signalling device
Series YL6S/2
• Select a mounting location that is suitable for the signal effect of the device, as well as
the required mounting and installation parameters (see "Technical data" chapter).
• Mount the device on a flat surface using the L-bracket and screw holes.
• Mount suitable approved electrical lines (see "Technical data" chapter) using a
suitable flameproof cable entry.
• Close unused entries using certified, flameproof stopping plugs.
7.3
Installation
The electrical installation and configuration of the device is performed in the following
sequence:
• Dismounting the device (see chapter 7.3.1)
• Electrical connections (see chapter 7.3.2)
• Configuration (see chapter 7.3.3)
• Mounting the device (see chapter 7.3.4)
• Mounting the earth connection (see chapter 7.3.5)
7.3.1 Dismounting the device
23036E00
• Loosen the 6 cheese-head screws (5)
and remove the flash flange.
23037E00
• Carefully remove the PCB (3) from the
enclosure (2) and detach the plug
connector from the PCB.
5
3
1
2