• Remove the closing cap of the central lock.
• Turn the central lock using a socket wrench M8, wrench size 13, by 90° to the left as
far as it will go.
• Swivel down the translucent cover.
• Proceed in reverse order to close.
• The seal of the translucent cover must lie correctly on the sealing edge.
• Push the closing cap onto the central lock opening (dust protection).
Note:
• Version without switch: Disconnect the luminaire from the power supply and secure it
against being switched on again.
• Version with switch: The luminaire is positively disconnected from the power supply by
actuating the central lock.
• In open end position and with translucent cover swivelled down, a restart lock-out
device prevents the central lock from being actuated.
Please do not use force!
When the translucent cover is closed, the central lock is released.