Compact Luminaire with LED
Series C-Lux 6102/1, Series C-Lux 6109/1
Closing the luminaire
20556E00
Place the cover onto the enclosure. Firmly press the lateral catches closed and
check that they have fully snapped in place (1).
20557E00
Tighten 4 x screws M5 x 12 with TX25 box spanner (2) (tightening torque 3 Nm).
DANGER! Explosion due to insufficient sealing of the device!
Non-compliance may result in serious or even fatal injuries.
Ensure that the catches fully snap into place on both sides of the luminaire when
closing.
Tighten all screws to the specified tightening torque.
When closing the luminaire, ensure that no electrical lines are caught and damaged
between the enclosure and the cover. Ensure that the electrical lines are securely fixed
in place with cable holders for this.