Stahl 9445/35 Series Operating Instructions Manual Download Page 47

IS1+ Remote I/O System 

for CL I, DIV 2 / Zone 2 

Overview 

 

 

9400 6 031 006 1 

2018 
 

08.03.  Bagusch 

 

 

Kaiser

 

2 of 2 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

I.

S

In

p

u

ts

 a

n

d

 Ou

tp

u

ts

 

C

las

s

 I

II

II

I,

 D

IV

 1

Gr

o

u

p

s

 A

-G;

 C

las

s

 I

Zon

e

 0

II

C

/I

IB

 

 

or 

N

o

n

 I

.S

o

N

o

n

inc

e

n

d

iv

e

 c

ir

c

u

it

s

C

las

s

 I

II

II

I,

 D

IV

 2

Gr

o

u

p

 A

-G

C

las

s

 I

Zon

e

 2

Gr

o

u

p

 I

IC

/I

IB

 

C

la

s

s

 I

D

IV

 2

 /

 Zo

n

e

 2

 o

n

o

n

 H

a

z

a

rd

o

u

s

 (

C

la

s

s

if

ie

d

L

o

c

a

tio

n

 

In

s

ta

lla

tion

 

B

lock

 D

ia

gra

m

 of

 a

 

Z

o

n

e 2

 Field Stat

ion

:

 

Summary of Contents for 9445/35 Series

Page 1: ...E DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE DE Betriebsanleitung Additional languages www r stahl com DE IS1 Power Modul f r Zone 2 Division 2 Reihe 9445 35 F r k nftige Verwendung a...

Page 2: ...ualifikation des Personals 5 3 3 Restrisiken 6 4 Transport und Lagerung 8 5 Produktauswahl und Projektierung 8 5 1 Redundanz 9 6 Montage und Installation 10 6 1 Montage Demontage 10 6 2 Austausch und...

Page 3: ...er des Ger ts weitergeben Betriebsanleitung bei jeder von R STAHL erhaltenen Erg nzung aktualisieren ID Nr 264697 944560310010 Publikationsnummer 2018 09 27 BA00 III de 01 Die Originalbetriebsanleitun...

Page 4: ...en zu schweren Verletzungen f hren kann VORSICHT Gefahrensituation die bei Nichtbeachtung der Sicherheitsma nahmen zu leichten Verletzungen f hren kann HINWEIS Gefahrensituation die bei Nichtbeachtung...

Page 5: ...2 Division 2 und im sicheren Bereich zugelassen Das Ger t ist f r den Einbau in Bereichen mit einem Verschmutzungsgrad 1 oder 2 gem IEC EN 60664 1 vorgesehen Zur bestimmungsgem en Verwendung geh ren d...

Page 6: ...ebungsbedingungen siehe Kapitel Technische Daten ber cksichtigen Ger t nicht belasten Verpackung und Ger t auf Besch digung pr fen Besch digungen umgehend an R STAHL melden Besch digtes Ger t nicht in...

Page 7: ...in Montage Installation Inbetriebnahme und Instandsetzung nur durch qualifizierte und autorisierte Personen siehe Kapitel 3 2 durchf hren lassen Korrekte Montagelage beachten siehe Kapitel Montage und...

Page 8: ...Arbeitsweise Der Anschluss der Hilfsenergie erfolgt ber eine steckbare Klemme mit Aderleitungen Werden zwei redundante Power Module eingesetzt erfolgt eine Lastaufteilung auf beide Das Power Modul 94...

Page 9: ...dant ausgef hrt werden Dabei wird zwischen CPU Power und System Vollredundanz unterschieden Folgende Tabelle zeigt die ben tigten Komponenten f r die jeweiligen Redundanzkonzepte System Vollredundanz...

Page 10: ...inbaubedingungen und Montageanweisungen genau durchlesen und exakt befolgen 6 1 1 Gebrauchslage Sockel ausschlie lich wie folgt montieren Montagelage horizontal mit Leserichtung von links oder Montage...

Page 11: ...35 nicht auf den Steckplatz Slot 0 stecken 6 2 Austausch und Upgrade des Moduls 6 2 1 Austausch des Power Moduls 9445 35 Stromversorgung des IS1 Remote I O System abschalten Sicherungsschraube am blau...

Page 12: ...Upgrade der IS1 Ethernet CPU Reihe 9441 15 auf IS1 CPU 9442 35 und Power Modul 9445 35 und Sockel 9496 35 IS1 Ethernet CPU und Power Modul entfernen siehe Betriebsanleitung 9441 15 Stromversorgung de...

Page 13: ...folgender Tabelle anschlie en Anschlussleitung gegen Zugbelastung und Scheuern sichern Trennen Sicherungsschrauben am Hilfsenergiestecker l sen Stecker am Hebel nach vorne klappen Dabei wird der Hilf...

Page 14: ...e auf die neue Version W hrend des Updates blinken die LEDs PWR OUT und M S LED Farbe Bedeutung PWR IN gr n Betriebsanzeige Hilfsenergie M S blau Wartungsbedarf oder au erhalb Spezifikation PWR OUT gr...

Page 15: ...der Spezifikation Power Modul berlastet Software Update Umgebungs temperatur verringern durch z B Beschattung oder K hlung Hinweis Ohne Behebung wird das Modul dauerhaft gesch digt Strombelastung des...

Page 16: ...rheit warten 9 3 Reparatur Reparaturen am Ger t nur durch R STAHL durchf hren lassen 10 R cksendung R cksendung bzw Verpackung der Ger te nur in Absprache mit R STAHL durchf hren Dazu mit der zust ndi...

Page 17: ...inigt werden Ger t nur mit feuchtem Tuch und ohne kratzende scheuernde oder aggressive Reinigungsmittel oder L sungen schonend reinigen 12 Entsorgung Nationale und lokal g ltige Vorschriften und geset...

Page 18: ...im sicheren Bereich Weitere Angaben siehe Betriebsanleitung und Bescheinigungen Technische Daten Elektrische Daten Hilfsenergie Nennspannung UN 24 V DC Spannungsbereich 19 32 V DC Abschaltung bei Unt...

Page 19: ...g an Sockel 9496 35 Umgebungsbedingungen Umgebungstemperatur Lagertemperatur 40 80 C Maximale relative Luftfeuchte 95 ohne Betauung Maximale Betriebsh he 2000 m Schock halbsinusf rmig IEC EN 60068 2 2...

Page 20: ...energiestecker L 181 mm B 96 mm H 160 mm Anzeige LED Anzeige Betriebsanzeige externe Versorgung LED PWR IN gr n Wartungsbedarf Modul LED M S blau Betriebsanzeige Versorgung CPU und I O Module LED PWR...

Page 21: ...chreibung 20020E00 1 Sicherungs schrauben Sicherungsschrauben f r mechanischen Steckverbinder 2 Sicherungs schraube Torx T20 zum Befestigen am Sockel 3 Hilfsenergie Anschluss kontakte X1 Mechanische S...

Page 22: ...DE DE DE IS1 Power Modul f r Zone 2 Division 2 Reihe 9445 35 15 2 Ma angaben Befestigungsma e Ma zeichnungen alle Ma e in mm Zoll nderungen vorbehalten 19757E00 Power Modul 9445 35 19756E00 Power Mod...

Page 23: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www r stahl com EN IS1 power module for Zone 2 Division 2 Series 9445 35 Save for futur...

Page 24: ...ualification 5 3 3 Residual Risks 6 4 Transport and Storage 8 5 Product Selection and Project Engineering 8 5 1 Redundancy 9 6 Mounting and Installation 10 6 1 Mounting Dismounting 10 6 2 Replacing an...

Page 25: ...ent owner or user of the device Update the operating instructions every time you receive an amendment to them from R STAHL ID No 264697 944560310010 Publication Code 2018 09 27 BA00 III en 01 The orig...

Page 26: ...s if the safety measures are not complied with CAUTION Dangerous situation which can result in minor injuries if the safety measures are not complied with NOTICE Dangerous situation which can result i...

Page 27: ...eas of Zone 2 Division 2 and in safe areas The device is intended for installation in areas with a degree of pollution of 1 or 2 in accordance with IEC EN 60664 1 Intended use includes complying with...

Page 28: ...on the device Check the packaging and the device for damage Report any damage to R STAHL immediately Do not commission a damaged device Store the device in its original packaging in a dry place with...

Page 29: ...in the vicinity Have mounting installation commissioning and maintenance performed only by qualified and authorised persons see Chapter 3 2 Observe the correct mounting position see the Mounting and...

Page 30: ...ted via a pluggable terminal with single cores If two redundant power modules are used the load is distributed to both modules The 9445 35 power module reports its respective state in case of overload...

Page 31: ...rotocol Here a distinction is made between CPU redundancy power redundancy and system redundancy full redundancy The following table shows the components required for the respective redundancy concept...

Page 32: ...ollowing installation conditions and assembly instructions carefully and follow them precisely 6 1 1 Operating Position Mount the base exclusively as follows Horizontal mounting position with a readin...

Page 33: ...nnect the 9445 35 power module to the slot slot 0 6 2 Replacing and Upgrading the Module 6 2 1 Replacing the 9445 35 Power Module Switch off the power supply to the IS1 Remote I O System Loosen the sa...

Page 34: ...and the 9442 35 operating instructions 6 2 3 Upgrade of the IS1 9441 15 Ethernet CPU Series to IS1 9442 35 CPU 9445 35 Power Module 9496 35 Base Remove the IS1 Ethernet CPU and power module see the 94...

Page 35: ...n accordance with the following table Secure the connection line against tensile load and scuffing Disconnecting Loosen the safety screws on the auxiliary power plug Push the lever for the plug forwar...

Page 36: ...automatically The PWR OUT and M S LEDs flash during the update LED Colour Meaning PWR IN green Auxiliary power operation indication M S blue Requires maintenance or outside specification PWR OUT green...

Page 37: ...de the specification Power module overloaded Software update Reduce ambient temperature for example by means of shading or cooling Note If the problem is not eliminated the module will be permanently...

Page 38: ...safety notes in these operating instructions Safety chapter 9 3 Repair Repair work on the device must be performed only by R STAHL 10 Returning the Device Only return or package the devices after con...

Page 39: ...ntly clean the device only with a damp cloth and without scratching abrasive or aggressive cleaning agents or solutions 12 Disposal Observe national and local regulations and statutory regulations reg...

Page 40: ...information see operating instructions and certificates Technical Data Electrical data Auxiliary power Nominal voltage UN 24 V DC Voltage range 19 to 32 V DC Disconnection when there is undervoltage...

Page 41: ...nnection To 9496 35 base Ambient conditions Ambient temperature Storage temperature 40 to 80 C Maximum relative humidity 95 without condensation Maximum operating height 2000 m Semi sinusoidal shock I...

Page 42: ...m W 96 mm H 160 mm Indication LED indication Operation indication for external supply PWR IN LED green Module requires maintenance M S LED blue Operation indication for supply to CPU and I O modules P...

Page 43: ...nent Description 20020E00 1 Safety screws Safety screws for mechanical plug connectors 2 Safety screw Torx T20 for fastening components to the base 3 Auxiliary power of X1 connector contacts Mechanica...

Page 44: ...1 power module for Zone 2 Division 2 Series 9445 35 15 2 Dimensions Fastening Dimensions Dimensional drawings all dimensions in mm inches Subject to modification 19757E00 9445 35 power module 19756E00...

Page 45: ......

Page 46: ...consist of the following major subsystems 1 Socket The Socket is the Backbone of the Remote I O System IS1 It provides connections for Power Modules and CPU Modules via the Backplane I O Modules are c...

Page 47: ...r 2 of 2 I S Inputs and Outputs Class I II III DIV 1 Groups A G Class I Zone 0 IIC IIB or Non I S or Nonincendive circuits Class I II III DIV 2 Group A G Class I Zone 2 Group IIC IIB Class I DIV 2 Zon...

Page 48: ...1 7 0 2 Nm o Plug the unpowered power supply connector into the Power Module o Secure the power supply connector by tighten both screws to the Power Module o Switch on the power supply Follow the pro...