IS1+ power module for Zone 2 / Division 2
Series 9445/35
3.3
Residual Risks
3.3.1 Explosion Hazard
Despite the device's state-of-the-art design, explosion hazards cannot be entirely eliminated
in hazardous areas.
Perform all work steps in hazardous areas with the utmost care at all times!
Transport, store, plan, install and operate the device in compliance with the technical data
exclusively (see the "Technical data" chapter).
Possible hazards (residual risks) can be categorised according to the following causes:
Mechanical damage
The device can be damaged during transport, mounting or commissioning.
This kind of damage can, for example, render the device's explosion protection partially or
fully ineffective. This may result in explosions causing serious or even fatal injury to persons
in the vicinity.
Only transport the device in special transport packaging that reliably protects the
devices from external influences. Observe the ambient conditions when selecting the
transport packaging (see the "Technical data" chapter).
Do not place any load on the device.
Check the packaging and the device for damage. Report any damage to R. STAHL
immediately. Do not commission a damaged device.
Store the device in its original packaging in a dry place (with no condensation),
and make sure that it is stable and protected against the effects of vibrations and knocks.
Do not damage the device and other system components during mounting.
Excessive heating or electrostatic charge
A defective device in the cabinet, operation outside of approved conditions or improper
cleaning can cause the device to heat up severely or to become electrostatically charged,
causing it to produce sparks. This may result in explosions causing serious or even fatal
injury to persons in the vicinity.
Operate the device only within the prescribed operating conditions
(see the type plate and the "Technical data" chapter).
Only mount the device on clean, flat contact surfaces of the base
(no stick
-
on labels, labelling or the like).
Install and adjust the cabinet in such a way that it is always operated within the permissible
temperature range.
Ensure that enough heat is being dissipated continuously, especially when mounting
without a mounting plate.
Ensure that a spring for heat dissipation is attached to the 9445/35 power module.
Here, carefully follow the information in the "Mounting and installation" chapter.