Installation Switch
Series 8040/11-V30
7.3.1 Electrical Connection
Circuit diagram of the device with connection designations and possible versions.
Observe the following points during the installation:
• One or two conductors can be installed to one connection terminal.
• In case of solid conductors, both conductors must have the same cross section and
must be made of the same material.
• The conductors can be connected without special preparatory measures.
DANGER
Explosion hazard as a result of incorrectly installed components!
Non-compliance results in severe or fatal injuries.
• Ensure that the conductor insulation goes all the way to the
terminal points.
• Do not allow the conductor to be damaged during stripping
(e.g. by scoring).
• Select suitable conductors and install them so that the maximum
permitted conductor temperature and the maximum permitted
surface temperature are not exceeded.
• Install the conductors so that mechanical damage to the conductor
insulation due to rubbing against sharp edges or moving metal
parts is prevented.
• Only use suitable tools to fit the core end sleeves (if necessary)
so that they are gas-tight.
• Always connect the protective conductor.
• Note the tightening torque for the clamping units.
08804E00