background image

SAFETY INSTRUCTIONS

Please read the instructions carefully as they include important 
information about the installation, operation and maintenance.

•  Please keep this user’s guide for future consultation. If you sell the unit to another 

user, be sure that they also receive this instruction booklet.

•  All fixtures leave the manufacturer intact. Please note that any damages incurred 

by the user is not covered by the guarantee.

•  Unpack and check carefully that there is no transportation damage before using 

the unit.

•  The unit is for indoor use only. Use only in a dry location.
•  Use a safety bond when attaching the fixture to a lighting rig. Handle by the 

hanging bracket when fixing.

•  The unit must be installed in a location with adequate ventilation at least 50 cm 

from adjacent surfaces.

•  Make sure that no ventilation slot is blocked, otherwise the unit will overheat.
•  Before operating, ensure that the voltage and frequency of the power supply 

match the power requirements of the unit.

•  Make sure all equipment is properly earthed.
•  Do not operate the unit if the ambient temperature is higher than 40°C. 
•  Do not hardwire to any mains dimmer.
•  On the first run there may be some normal operational start-up smell.
•  Make sure that there is no flammable material close to the unit while operating, as 

it is a fire hazard.

•  Look over power wires carefully and replace immediately if there is any damage.
•  Never run on for a long time lest shortening lifespan. Avoid any inflammable 

liquids, water or metal objects entering the unit. In case it happens, cut off the 
mains power immediately.

•  Do not operate in a dirty or dusty environment. Clean fixtures regularly.

!

Summary of Contents for EcoPar186

Page 1: ...Please read the instructions carefully before use USER MANUAL EcoPar186 SLI ECOPAR186 ...

Page 2: ......

Page 3: ...with adequate ventilation at least 50 cm from adjacent surfaces Make sure that no ventilation slot is blocked otherwise the unit will overheat Before operating ensure that the voltage and frequency of the power supply match the power requirements of the unit Make sure all equipment is properly earthed Do not operate the unit if the ambient temperature is higher than 40 C Do not hardwire to any mai...

Page 4: ...e unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance centre Disconnect the mains power if the fixture is not used for a long time Use the original packaging to transport regarding any warranty issue Do not look directly at the LED light beam while the fixture is on Do not connect more than 7 units to...

Page 5: ...isplay 4 digit Housing ABS Fixation 2 brackets to hang or lay the spotlight Input and output 3 pin DMX and IEC Cooling Low noise fan Use Indoor Power consumption 15 watts Dimensions 24 x 23 5 x 8 cm 9 4 x 9 3 x 3 1 Weight 1 kg 2 2 lb Included Remote control BACK PANEL 1 Function display 2 Menu buttons 3 DMX output 4 DMX input 5 IEC input 6 IEC output 7 Microphone 7 4 3 2 1 24 cm 23 5 cm 5 6 ...

Page 6: ... 7 Performance mode Stro 0 255 FAde SP 1 SP 8 Soun yeS Auto yeS Led on Switching on or off the display oFF dISP dISP Reversing the display d5IP bALA RED 125 White balance 255 Blue 125 255 Gree 125 255 MANU RED 0 Manual mode 255 BLUE 0 255 GREE 0 255 Unbe 0 255 teSt Test mode Fhr5 Hours of operation RF YeS Remote control no teMP Current temperature ...

Page 7: ...onfirm Press the menu button to return to the main menu Channel selection mode With the menu button select the channel selection mode ChMd and press the enter key to confirm Then use the up and down buttons to choose the desired mode that is 4 channels 4Ch or channels 8Ch and press the enter key to confirm Press the menu button to return to the main menu 4 CH CHANNEL MODE 8 CH CHANNEL MODE ...

Page 8: ... 8 Each value corresponds to a specific speed Press the enter key to confirm In the sound mode you can decide to activate yes or deactivate no the sound control When the sound mode is on the spotlight reacts to sound When the sound mode is off the spotlight does not react to sound Press the enter key to confirm your choice and press the menu button to return to the main menu In the auto mode you c...

Page 9: ...displayed Press the menu button to return to the main menu Test mode With the menu button select the test mode teSt and press the enter key to confirm The machine automatically starts to diffuse colours Press the menu button to return to the main menu Hours of operation With the menu button select the hours of operation mode Fhr5 and press the enter key to confirm The number of hours that the devi...

Page 10: ...n intelligent lighting control with a maximum of 512 channels Warning To avoid signal transmission problems and interferences when using fixtures in chain use a Stagg N series professional 3 pin DMX terminator resistance 120 ohms pin2 DMX pin3 DMX ...

Page 11: ...dry the parts carefully Clean the internal optics at least every 30 days Clean the external optics at least every 20 days INFRARED REMOTE CONTROL Functions 1 ON Turn on the fixture 2 OFF Turn off the fixture 3 and Adjust various parameters of the fixture 4 R Red colour setting 5 G Green colour setting 6 B Blue colour setting 7 W White colour setting 8 A Not applicable 9 UV Not applicable 10 Sound ...

Page 12: ...10 2016 ...