background image

17

CH1

DMX Value

Snow Volume

250-255

AUTO 

Random Snow

0-249

*** 

The air volume setting needs to be set in the panel.

**Interval =0 means constant spraying snow.

**S=seconds

100%

0%

3 CH

1 CH

5 CH

CH1

CH2

CH3

DMX Value

Snow Volume

DMX Value

Air Volume

DMX Value

ON/OFF

250-255

AUTO 

Random Snow

250-255

AUTO

50% or 100% 

random change

128-255

Snow ON

0-249

0-100%

125-249

100%

0-127

Snow OFF

0-124

50%

CH1

CH2

CH3

CH4

CH5

DMX Value Snow Volume DMX Value Air Volume

DMX Value ON/OFF

DMX Value Duration DMX Value Interval

250-255

AUTO,

Random Snow

250-255

AUTO,

50% or 100% 

random change

128-255

Snow ON

0-255

0-255 s

0-255

0-2550 s

0-249

0-100%

125-249

100%

0-127

Snow OFF

0-124

50%

Figure 2 DMX Chart

Summary of Contents for BURAN 1300

Page 1: ...ENGLISH BURAN 1300 Version 1 0 ...

Page 2: ...n Appendix A VT 1 22 CONTENTS If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Read the manual Indoor use only This symbol indicating separate collection for electrical and electronic equipment Warning situations that could cause injury to yourself or others Caution situations that could cause damage t...

Page 3: ...sconnect power supply Contact a service technician to determine safety for use Machine must disconnect from electric mains power supply before cleaning servicing or storing Long distance movement please be sure to empty the tank Thank you for selecting our BURAN 1300 you already own the high tech professional DMX snow machine Better read the manual thoroughly before operation follow instruction wi...

Page 4: ...achine away from flames and flammable items Use only high quality snow fluid Never put flammable substances into the tank Never put any flammable material lipid gas perfume etc into the tank read the user manual thoroughly before operation Better use our high quality snow fluid random use with other snow fluid may make bad effect or causing damage to the machine Keep sufficient snow fluid in tank ...

Page 5: ...rticular Warning When the snow machine is idle and does not work it is recommended to empty the tank and make a cleaning procedures put the water into the tank in accordance with spray snow operation to clean the interior of the snow machine until the water is almost no foam so far Please note that the snow fluid long time placed in the snow machine the snow fluid becomes sticky and the snow machi...

Page 6: ...thout any prior written notice Important The wires in this mains lead are colored in accordance with the following code EU Green and Yellow Earthed E Blue Neutral N Brown Live L Warning This appliance must be earthed USA Green and Yellow Earthed E White Neutral N Black Live L Warning This appliance must be earthed ...

Page 7: ...or D Inlet with Magnetic air filter E Snow Nozzle with cloth F LCD display G MENU H UP I DOWN J Manual ON OFF LED Indicator K Manual ON OFF L Timer ON OFF LED Indicator M Timer ON OFF N Control Socket Connection O DMX 3 PIN XLR Output P DMX 3 PIN XLR Input Q DMX 5 PIN XLR Output R DMX 5 PIN XLR Input S Power Input T NFB No Fuse Breaker U Power Switch V Suspension Safety Ring W Pad ...

Page 8: ...trol from 0 100 Could flexible with the speed of the fan Suitable for operation in any locations 50 and 100 air volume adjustment Quiet and smooth air volume adjustment let the spread of snow softer 100 high fan speed let the snow be even and expand more quickly throughout the location Special sound insulation design to achieve the effect of ultra quiet Multi function operation control Built In ti...

Page 9: ... One BURAN 1300 Snow Machine 2 One powerCON cable 3 One product user manual Mounting BURAN 1300 is shipped complete ready to use The bracket is installed before shipping the unit can be hung in any position Fasten the snow machine onto firm trussing Use a 20 kg rated or stronger C clamp bolted onto the bracket enhancing safety necessarily with safety cables Allow enough space around 20cm on all si...

Page 10: ...ube with filter deep inside the full fluid tank Figure1 B Please use dealer recommended high quality snow liquid only 5 Connect the quick connector with the liquid tank cap Figure 1 C Be sure of well connection 6 Plug mains power cord from the snow machine into appropriate power supply socket 7 Use LCD display Function buttons for operating control or connect DMX controller for setting 8 Or firmly...

Page 11: ...rmation 5 pin XLR 3 pin XLR 1 Ground 1 Ground 1 Ground 1 Ground 2 Cold 2 Cold 2 Cold 2 Cold 3 Hot 3 Hot 3 Hot 3 Hot 4 N A 4 N A 5 N A 5 N A XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive Pin 4 No use Pin 5 No use XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive ...

Page 12: ...e address 001 512 Press UP Down 1 5 seconds can change value continuously and fast pressed UP DOWN at the same time value back to 1 C SNOW V A Setting of snow modes there are two modes Fixed volume V and random volume Auto 1 V001 V100 Fixed snow volume The number after V is the concrete value For example V30 means 30 2 A001 100 Interchange of snow volume every 5 15 seconds automatically do not nee...

Page 13: ...pection function automatically Some points need to be paid attention to The machine cannot draw fluid in the case of 20 to 35 seconds will automatically shut down When the machine detects that no fluid will stop the LCD display will show NO FLUID If the machine detects no fluid during operation the machine stops working At this moment it is allowed to supplement fluid in the tank and then press bu...

Page 14: ...are connected to the machine appears problem of priority among the panel control DMX console and VT 1 controller There s no apparent priority among the three controls The one which has change action gets the priority of control 1 If DMX values changes of each DMX channel by DMX console the control priority is DMX console 2 If wanting VT 1 to have the control priority turn the knob to OFF then to O...

Page 15: ...al is not connected FN2 0 H V1 Press MENU to select the SNOW status use Up Down button to switch fixed volume V1 100 and random volume Auto The left icon is SNOW in Auto volume The display information as shown on the left FN20 shows lighted mode of the display H shows the state of air volume as shown in Figure H that air volume is 50 Vx shows the current set of snow volume as shown in Figure V100 ...

Page 16: ...e Up Down button to switch fixed volume V1 100 and random volume Auto The left icon is SNOW in Auto volume Press MENU to select the WIND status use Up Down button to switch air volume There are three changes Half 50 Full 100 and Auto random volume The left icon is WIND in Auto volume Press MENU to select the Interval status use Up Down button to switch the value of interval the range is 20 2000 se...

Page 17: ...formation as shown on the left The upper left for the DURATION shown as 6 seconds the upper right for the INTERVAL as shown in Figure 20 seconds The left lower for air volume as shown in the figure AUTO the lower right for snow volume as shown in Figure V100 7 Press Timer ON OFF button again to stop timing snow spray LED upper the button off 6 20 A V100 6 4 Refer to your controller manual for oper...

Page 18: ...socket Figure 1 O or Q on the back of the first BURAN 1300 plug the other end of the signal cable to the input socket Figure 1 P or R on the back of the second BURAN 1300 Follow the same procedure to link more snow machines if desired whole link is daisy chain 6 Down Refer to DMX channel chart in Figure 2 make related settings Now start operating BURAN 1300 with DMX console Press MENU to select th...

Page 19: ...olume DMX Value ON OFF 250 255 AUTO Random Snow 250 255 AUTO 50 or 100 random change 128 255 Snow ON 0 249 0 100 125 249 100 0 127 Snow OFF 0 124 50 CH1 CH2 CH3 CH4 CH5 DMXValue SnowVolume DMXValue AirVolume DMXValue ON OFF DMXValue Duration DMXValue Interval 250 255 AUTO Random Snow 250 255 AUTO 50 or 100 random change 128 255 Snow ON 0 255 0 255 s 0 255 0 2550 s 0 249 0 100 125 249 100 0 127 Sno...

Page 20: ...Plug the unit into grounded electric power supply socket with proper voltage 2 LCD display is lit and check if it can operate 3 The control panel operation is correct 4 Make sure the signal cable polarity is correct and good connection 5 Check your controller if in correct connection test the battery if power enough for wireless controller 6 Check your DMX address setting 7 If the pipe connected t...

Page 21: ...d to get dirty Be sure to always clean or replace the caps on the tank Replace the caps on the tank directly This kit includes quick connector cap pipe and filter and tight the cover of the snow machine tank immediately after filling 3 Remove the black cloth of the nozzle cleaning or replacement of the nozzle the nozzle need to maintain unobstructed Exit black cloth Core spring Nozzle Clip out the...

Page 22: ...achine is idle and does not work it is recommended to empty the tank and make a cleaning procedures put the water into the tank in accordance with spray snow operation to clean the interior of the snow machine until the water is almost no foam so far Please note that the snow fluid long time placed in the snow machine the snow fluid becomes sticky and the snow machine components are stuck this cou...

Page 23: ...now and air volume adjustment Automatic snow and air volume adjustment Timing Snow Low Fluid Shutdown Yes Fluid Consumption Rate ml min 500 Snow Highest Height m 10 Snow Longest Distance m 12 Display LCD Tank L 5 6 Hanging Bracket YES DMX Connectors 3P 5P XLR Remote Connector 1 4 JACK Voltage 120V 60Hz 230V 240V 50Hz Dimensions mm LxWxH w o bracket 550 376 439mm Weight kg 13 5 Controller Included ...

Page 24: ...unterclockwise to the end note that the switch does not turn off at this time snow spraying is shot down turned clockwise function of continuous snow spray is started 2 Turning the knob counterclockwise to decrease snow volume clockwise to increase snow volume B Air volume adjustment 1 Each time you switch the knob OFF ON there will be Kara sound you can switch the different air volume 2 The proce...

Page 25: ... LED power Controller power cord length 3 m Connector 1 4 stereo jack Function Air volume adjustment ON OFF Model VT 1 Cable Length 3m Effective Distance N A Connector 1 4 stereo jack Function ON OFF Volume adjustment Dimension LxWxH 90 x 50 x 39 mm Weight 0 257 kg Appendix A VT 1 ...

Page 26: ...Save this instruction properly All the information is subject to change without prior notice B U R A N 1 3 0 0 ...

Reviews: