4-2
DS50 USER MANUAL
R
stage accompany
O
P
E
R
A
TIO
N
4.2.1
Gain
Adjust the gain by dialing the rotary encoder. The gain is adjusted in steps of 0.25dB.
Smaller steps (0.01dB) can be set via the PC or MAC interface.
MENU
In 1 Gain
0dB
EXIT
SELECT
4.2.2
Input Selection
The DS50 inputs are fixed. Input 1 is routed from the analog XLR-input of channel 1,
channel 2 is routed from the analog XLR-input of channel 2, channel 3 and 4 are routed
from the digital AES/EBU XLR-input on the backside of the DS50.
4.2.3
Delay
Set the delay time by turning the encoder. The delay time on the front will be shown in ms, by
controlling the DS50 with StageControl the displayed unit can be changed between ms or s,
mm or m, feet, inches, or mils.
MENU
In 1 Delay
1.020ms
EXIT
SELECT
4.2.4
Low Pass Filter
Adjust the Low Pass Filter frequency by turning the rotary encoder. You can switch the low
pass filter off by turning the rotary encoder up (clockwise) until the frequency passes 20kHz.
Press the rotary encoder to change the filter type. Selct the type by turning the rotary encoder.
You can choose from: Butterworth 6dB, Bessel 6dB, Butterworth 12dB, Bessel 12dB, Linkwitz
Riley 12dB, Butterworth 18dB, Bessel 18dB, Butterworth 24dB, Bessel 24dB. Higher order
filters may be set by adding filter sections in the PEQ blocks (see below).
Enable or disable the Low Pass filter by rotating the encoder between on and off.
MENU
In 1 LowPass
Freq: 14500Hz
MENU
In 1 LowPass
Type: BUT 24dB
EXIT
SELECT
EXIT
SELECT
MENU
In 1 LowPass
Enabled: On
EXIT
SELECT