Page
ST325 User Handbook
4
Contents
Content
s
At a Glance .......................................................................................... 2
Quick Start Guide................................................................................. 3
Contents............................................................................................... 4
Features ............................................................................................... 4
Turning On ........................................................................................... 5
Programming..................................................................................... 6-8
Sample Ceramics Programs ................................................................ 9
Temperature Display.......................................................................... 10
Firing .................................................................................................. 11
Sample Glass Programs ............................................................... 12-13
Cooling ............................................................................................... 14
Operating Notes ................................................................................. 15
Adjusting While Firing.................................................................... 16-17
Other Features ................................................................................... 18
Card Reader....................................................................................... 19
Control Relay ................................................................................ 19-21
Error Messages............................................................................. 22-23
Program Record Sheet....................................................................... 24
•
Multi-zone
•
32 programs each with up to 32 segments
•
1 controlled heating / cooling ramp + soak per segment
•
Soak times up to nearly 100 hours
•
Ramp rates from 1 to 999°C/hour + full
•
Ideal for glass or ceramics use
•
Programs can be altered while firing
•
Program pause + segment advance facilities
•
Event / Damper Relay Output
•
Keyboard lockable
•
Delayed start facility - up to nearly 100 hours
•
Power failure recovery
•
Info key for energy used & set point display
•
Alarm Buzzer & Alarm Relay Output
•
Mains power switch
•
Micro-SD memory card reader
Features
Features
ST325 User Handbook
Page
21
FAn
.
1
°C
°C/hr
hr.min
200
°C
°C/hr
hr.min
FAn
.
0
°C
°C/hr
hr.min
700
°C
°C/hr
hr.min
At the start of the firing the fan remains off while the kiln temperature is
below the fan start temperature. The fan starts when the kiln temperature
has risen to the fan start temperature and remains on until the kiln tem-
perature has risen to the fan stop temperature. The fan then turns off and
stays off until the end of the program.
The instrument will now reset and the new fan control temperatures will
be stored.
Note: in the sequence above it is important that the
¨
key is
pressed a total of 4 times else configuration changes will not be
saved.
Fan Operation
Fan Output
To enter damper temperature configuration mode press and hold down
the
§
&
¨
keys at the same time while the controller is not running a
program (FIRING LAMP not lit).
Note: in the sequence below if no key presses are detected within
15 seconds the instrument will exit configuration mode and configu-
ration changes will not be saved.
The fan start temperature prompt is
shown. Release the
§
&
¨
keys.
Press the
¨
key.
The fan start temperature is now shown.
Adjust with the
©
&
ª
keys (hold down
for acceleration).
Press the
¨
key.
The fan stop temperature prompt is now
shown.
Press the
¨
key.
The fan stop temperature is now shown.
Adjust with the
©
&
ª
keys (hold down
for acceleration)
Press the
¨
key.
Control Relay