background image

04

03. ELECTRICAL CONNECTION

ü

Make connections with power supply disconnected. 

ü

Check that the power supply does not depend from electrical circuits for lighting. 

ü

Always connect the motor to the grounding system (yellow/green). 

ü

The supply line must be equipped with a circuit breaker. The supply line must be fitted with a device 
with a voltage category III, i.e. the distance between the contacts must be of 3,5 mm at least.

ü

The product doesn’t not provide any protection against overloads or short circuits. Provide the supply 
line with an adequate protection to the load, for example a fuse of maximum value 500 mA.

ü

The section of the connecting cables must be proportionate to their length and to the absorption of the 
load, and in any case not less than 1,5 mm.

ü

Once the electrical connections are finished, bring the motor/motors to the intermediate 
position and check that in the “wind alarm” condition the module commands the upward 
movement to the motor/motors 

(to exit form the”wind alarm”, press any buttons P1, P2 or P3).

L (Phase)

N (Neutral)

MAIN POWER 

SUPPLY

connector

cable 593.K.XS.00

FUSE 500mA

04. MEMORIZATION/CANCELLATION OF 593.K.XS.00 IN A RECEIVER

The procedure to memorize or delete 593.K.XS.00 in a receiver depends on the receiver, but usually is the following: 
- with the transmitter bring the motor/receiver to the intermediate position. 
- press PROG on the transmitter (with 594.T.X... in the battery compartment. / with 593.T.X1.00 in the back in the hole) for around 5 seconds to let the 

motor/receiver enter into the programming (the motor/receiver makes a signal)

 

  Art. 594.T.X...                                                      Art. 593.T.X1.00

- press P1 on 593.K.XS.00 and hold it until the motor/receiver confirmation movement.

To check that the radio sensor is correctly stored on the receiving device, give an up or down command to the receiver: shortly pressing P1 on the radio 
sensor, the movement must stop.  

brown

blue

P1

Summary of Contents for 593.K.XS.00

Page 1: ...USER MANUAL Radio wind sun sensor www stafer com 593 K XS 00 433 42 MHz versione 2 0 recycled paper ...

Page 2: ...ation of Stafer S p A liability and warranty The installer after the installation of the product must teach the end user about the working way of the automation and provide him with the user manual Warning ü Power supply 120 or 230 Vac 50 60 Hz ü Dimensions 236 x 54 x 73 mm ü Weight 200 gr ü Working temperature from 20 to 55 C ü Wind threshold from 5 to 35 Km h ü Sun threshold from 1 to 45 Klux ü ...

Page 3: ...ated by the sensor and by the receiver of the blind to be commanded Although the range in favorable conditions open field can be 100m it is advisable to not exceed 20 30m It is also advisable to check that there are no other radio devices working at the same frequency or with continuous transmission on the same area such as alarms radio headphones etc these could further reduce the range ü If ther...

Page 4: ...Plug up the cable through the provided retaining cable using the two screws F Close the two screws that fix the wall support and sensor using suitable tools B Close the cover G Unscrew the screw and open the closing cover placed under the sensor D WARNING Adjusting and fixing screws 7 must never be completely unscrewed Notes ü the product has been studied to be installed with the blades facing dow...

Page 5: ... the intermediate position and check that in the wind alarm condition the module commands the upward movement to the motor motors to exit form the wind alarm press any buttons P1 P2 or P3 L Phase N Neutral MAIN POWER SUPPLY connector cable 593 K XS 00 FUSE 500mA 04 MEMORIZATION CANCELLATION OF 593 K XS 00 IN A RECEIVER The procedure to memorize or delete 593 K XS 00 in a receiver depends on the re...

Page 6: ... these adjustments from a remote control 05 WIND SENSOR 05 1 WIND THRESHOLD ADJUSTING THROUGH THE BUTTONS ON THE SENSOR Press P1 until LED 1 starts to flash signalling the current wind threshold Press P1 to set the tens and P3 to set the units The device signals the new value and exits from the programmation If the value is the desired one wait 10 seconds the device signals again the value and exi...

Page 7: ... LED Manoeuvre BLINKING is just exit from wind alarm and has not yet made any automatic operation concerning the sun 06 SUN SENSOR Notes ü 1 press the buttons within 10 seconds from the last flash of LED 2 The buttons must be shortly pressed around 1 second between two pressures Press the buttons the same number of time of the desired value e g press 8 times P3 to set 8 Klux press 2 times P1 to se...

Page 8: ...e that device enter in wind alarm ü Interferences on Radio connection Verify that there are no interferences on same frequency 08 FAQ ü Verify the power supply ü Once powered the device lights LEDs briefly to indicate the proper power supply If this doesn t happen it is likely a fault and it may be necessary to replace the device or there is an error in the electrical connection ü Ensuring to have...