Laser type:  LAX 600 

Red diode laser,  wavelength 635 nm

  

LAX 600 G 

Green diode laser, wavelength 510–530 nm

Power output: 

 

< 1 mW, laser class 2 in accordance with IEC 60825-1:2014 

Self-levelling range: approx.  ± 4°
Levelling accuracy*:

Laser line: 

 

±0.3 mm/m      ± 3/16“ over 50ft     centre of laser line

90° accuracy: 

 

±0.3 mm/m      ± 3/16“ over 50ft

Batteries: 

 

12 V 2 Ah Li-ion CAS battery pack 

 

 

 

12 V 4 Ah Li-ion CAS battery pack 

Battery life: 
  

  LAX 600 ≤ 28 h

  

  LAX 600G ≤ 15 h

Operating temperature range:    

-10°C to +40°C    /  14°F to 104°F

Storage temperature range:        

-20°C to +63 °C   /  -4°F to 145°F

Subject to technical modifications.
* When operated within the specified operating temperature range

2022

Summary of Contents for LAX 600 Series

Page 1: ...How true pro s measure LAX 600 series Operating instructions 3x 360 LINES ...

Page 2: ... 4 Commissioning 5 4 1 Inserting and charging the battery 5 4 2 Switching the unit on 6 4 3 Commissioning without the levelling function 6 5 Functions 7 5 1 Selecting laser functions 7 5 2 Working with the receiver 7 6 LED indicators 8 7 Using the SWB10 bracket 9 8 Checking the accuracy 10 8 1 Vertical check 10 8 2 Horizontal check 11 8 3 Angle check 12 9 Technical data 13 ...

Page 3: ... Plumb line laser function Manual mode 1 4 tripod socket Carrying case STABILA CAS 12 V Li Power 2 0 Ah battery not included in every set SC 30 charger 12 18 V CAS system not included in every set LAX 600 G Includes green laser beams to improve visibility with the naked eye 2 2 Safety instructions for the Li ion battery pack Thoroughly read the safety instructions and operating instructions for th...

Page 4: ...l laser line 10 Button Pulse mode for receiver operation 11 Battery 12 Battery release 13 Red button Activation of the capacity display 14 Green LED Display of charge capacity 15 Serial number 16 1 4 tripod socket 17 Casing Protected against water jets and dust in accordance with IP 65 18 SUB 10 19 1 4 connection bolt 20 Hanging hole 21 Magnet surface 22 1 4 5 8 tripod socket 23 SWB 10 24 Hanging ...

Page 5: ...y pack must not be inserted in the charger LED display low charge capacity 20 charge the battery pack Do not allow the battery pack to become fully discharged Charging the battery pack Thoroughly read the safety instructions and operating instructions for the battery pack Release the locking device and remove the battery pack from the laser unit Insert the battery pack into the charger Connect the...

Page 6: ...elling function Marking function mode can only be switched on with the Manual mode switch The laser beam flashes twice every 5 seconds The LAX 600 LAX 600 G is not in self levelling mode and can only be used in this mode for marking and alignment Always use the centre of the laser line when marking and aligning The laser beam flashes if the inclination of the laser unit is too steep The laser unit...

Page 7: ...t possible to switch off all of the laser lines at the same time via the Laser lines buttons One laser line therefore always remains activated and visible All of the laser lines can only be switched off via the sliding switch or via the man button in manual mode 5 2 Working with the receiver Pulse mode must be activated for work completed over larger distances or using a suitable receiver Note The...

Page 8: ...racy Operation activated Battery temperature 70 C 158 F Ensure the unit is in the operating temperature range Check accuracy 6 LED indicators Operation activated Unit temperature 60 C 140 F Ensure the unit is in the operating temperature range Operation activated Battery check failed Replace the battery pack Operation activated Get in touch with STABILA CAS battery charge capacity too low Insert b...

Page 9: ...The LAX 600 LAX 600G is bolted to the retaining bracket Using the magnet surface the retaining bracket is either attached to the sliding plate on the bracket or directly to magnetic metal surfaces The bracket must roughly be aligned vertically using the adjusting screw so that the LAX 600 LAX 600G is in the self levelling range Once the clamping screw has been released the LAX 600 LAX 600G can be ...

Page 10: ...ore than 1 mm 11 256 5 Perform this check for both vertical laser lines 8 Checking the accuracy The LAX 600 LAX 600G is designed for use on building sites and is perfectly adjusted before leaving our premises As with all precision instruments check the calibration accuracy of the unit on a regular basis Always check the unit before you start work especially if it has been exposed to heavy vibratio...

Page 11: ...aser unit through 90 without altering the height of the laser i e do not change the tripod height Allow the unit to level itself again automatically 5 Mark the centre of the laser lines on the wall point 2 6 Repeat steps 4 and 5 twice to obtain points 3 and 4 7 If the differences between the four control points are less than 6 mm 1 4 for a distance of 10 m 32 10 the unit is within its permitted to...

Page 12: ...gn the LAX 600 LAX 600G with point C again using the laser line 8 Precisely mark point D on the other wall or on the floor using the 90 laser line Note The distance from A to B B to C and B to D should be the same to guarantee accuracy 9 Turn the LAX 600 LAX 600 G through 90 and align the first laser line with point D 10 Mark position E on the perpendicular second laser line as close as possible t...

Page 13: ... Levelling accuracy Laser line 0 3 mm m 3 16 over 50ft centre of laser line 90 accuracy 0 3 mm m 3 16 over 50ft Batteries 12 V 2 Ah Li ion CAS battery pack 12 V 4 Ah Li ion CAS battery pack Battery life LAX 600 28 h LAX 600G 15 h Operating temperature range 10 C to 40 C 14 F to 104 F Storage temperature range 20 C to 63 C 4 F to 145 F Subject to technical modifications When operated within the spe...

Page 14: ......

Reviews: