background image

The LAX 200 crossed line laser is designed for use on construction sites and 

was perfectly adjusted when it left our factory. As with any precision instrument, 

however, its calibration must be regularly checked. The unit should be checked 

before starting any new tasks, particularly when the unit has been exposed to 

strong vibrations. After an impact, the unit should be checked throughout its 

whole self-leveling range. 

Checking the calibration

You must create a reference to perform this test.

Fasten a plumbline near to the wall.

The laser unit should now be set up in front of this reference mark

(distance Y) and the vertical laser line compared with it.

The discrepancy between the centre of the laser line and the reference mark 

should be no greater than 3/64” ( 1 mm) 

 

over a length of 8 ft  (2 m) . 

Vertical check

D1

D2

D3

-> The unit is inclined too much 

 + is outside the self-leveling range 

 + the laser cannot level itself automatically

laser beam 

flashing

The laser will flash if the inclination is too great.

Setting the type of line:

The vertical line, 

horizontal line 

and the cross 

laser line can be 

activated in suc-

cession by using 

the selector 

switch (1a)

Operating mode without leveling function

The on/off switch (1b) is switched off 

In this mode the LAX 200 is 

only switched on or off with 

the selector switch (1a).

Summary of Contents for LAX 200

Page 1: ...Laser LAX 200 Operating instructions en...

Page 2: ...1 2 B1 B2 9 105 mm 570 gr 115 mm 59 mm L1 L2 C2 C1 3 8 ov 100 ft 4 4 20 1 ounces 1 8 2 10 5 6...

Page 3: ...A 4 6 1b 1a 2a 2b 3 7 8 5...

Page 4: ...2m D1 E1 D2 E2 E3 1 X1 Y1 2 X2 Y2 3 X3 Y3 4 ft 8 ft...

Page 5: ...F1 F2 F3 F4 F5 2m D3 s 5m 16 5 s 8 ft 1 mm 3 64...

Page 6: ...ables working over larger distances using a special laser line receiver see line receiver manual We have endeavoured to explain the unit s handling and functioning in as clear and comprehensible manne...

Page 7: ...e units are not safety goggles They are designed to make the laser light easier to see Do not let the unit fall into children s hands EN 60825 1 03 10 The use of operating and adjustment equipment oth...

Page 8: ...be set up in front of this reference mark distance Y and the vertical laser line compared with it The discrepancy between the centre of the laser line and the reference mark should be no greater than...

Page 9: ...er line height matches that of point 2 8 1 Horizontal check Line level F1 F2 F3 F4 F5 E1 E2 E3 Mark three points 1 2 and 3 on the floor at a distance of 16 5 5 m from each other the points must be in...

Page 10: ...ery cover 4 in the direction of the arrow and insert new batteries in accordance with the symbols in the battery compartment Replacing the batteries Mignon AA LR6 4 Tip Remove the batteries if the uni...

Page 11: ...hase Any faults will be eliminated at Stabila s own discretion either by repairing or replacing the unit Stabila accepts no wider claims No liability is accepted for any faults due to inappropriate tr...

Page 12: ...i hele verden Takuuilmoituksen t ydennys Takuu on voimassa maailmanlaajuisesti Supplement til garantierkl ring Garantien g lder internationalt Komplettering till garantif rklaring Garantin g ller i he...

Reviews: