STA-RITE Signature 2000 HP20E-01 Owner'S Manual Download Page 8

Mechanical Seal Changeout
(refer to Figures 7 and 8)

This procedure is best completed with the pump held in
a vertical position, motor down.
First complete “Disassembly” instructions 1 through 5
under “Impeller Stack Changeout.” (see Figure 7).

6. Remove 4 capscrews holding pump body to motor.

Pump handle will come off with top capscrews.

7. Unscrew pump shell from pump body, turning

clockwise (left hand threads).

8. Remove mechanical shaft seal spring and rotating

half from motor shaft. Use care not to scratch motor
shaft when removing rotating half.

9. Remove pump body from motor and place on flat

surface, face down. Again, use care not to scratch
motor shaft.

10. Use a screwdriver to push ceramic seat out from

seal cavity as shown.

11. Installation of ceramic seat:

A. Turn pump body over so seal cavity is up; clean

cavity thoroughly.

B. Clean polished surface of ceramic seat with a

clean cloth.

C. Lubricate outside rubber surface of seat with

soapy water. Place cardboard washer over

polished face of seat and press into seal cavity
using a 3/4” socket or a piece of 3/4” standard
pipe.

D. Be sure polished surface of seat is free of dirt

and has not been damaged by insertion. Re-
move excess soapy water. Dispose of card-
board washer.

12. Installation of rotating half and spring:

A. Reinstall pump body on motor using extreme

caution not to hit ceramic portion of seal on
motor shaft. Reattach pump body to motor using
capscrews. Be sure to reinstall pump handle at
this time.

B. Inspect shaft to make sure that it is clean.

C. Clean face of rotating half of seal with a clean

cloth.

D. Lubricate inside diameter of rotating half with

soapy water and slide onto motor shaft (sealing
face first).

E. Place spring over motor shaft so it rests on

rotating half.

13. To complete reassembly from this point, reverse

instructions 1 through 5 under “Impeller Stack
Changeout.”

NOTICE: Lubricate suction and discharge O-Rings
with soapy water for easier installation of shell.

Ceramic Seat

3/4" pipe or
3/4" socket
with extender 

Polished
Face

Rotating
Half

Cardboard
washer (supplied
       w/seal)

Rotating Half
of Mechanical
Seal

Remove shell;
turn clockwise.

Push ceramic
seat out of
pump body

Remove
Pump Body

6

8

7

9

10

11

12

1212 0894

Figure 8 – Mechanical seal changeout.

8

Summary of Contents for Signature 2000 HP20E-01

Page 1: ...rough 1 1 2 HP STA RITE INDUSTRIES INC DELAVAN WISCONSIN 53115 Printed in U S A 1998 Sta Rite Industries Inc S327 Rev 6 23 98 MODEL HP PHASE AVG GPM HP7C 01 1 2 1 7 HP7C3 01 1 2 3 7 HP7D 01 3 4 1 7 HP...

Page 2: ...important but not related to hazards GENERAL SAFETY To avoid risk of serious bodily injury and property damage read safety instructions carefully before installing pump Do not allow pump or any system...

Page 3: ...GPM Rated Flow No Flow HP7C HP7C3 1 2 9 7 90 130 HP7D HP7D3 3 4 12 7 123 173 HP7E HP7E3 1 16 7 162 229 HP20E HP20E3 1 7 20 75 110 HP20F HP20F3 1 1 2 9 20 97 143 For total discharge pressure add this p...

Page 4: ...pump to replace seal See Maintenance Pages 7 and 8 OPERATION NOTICE Observe the following precautions when operating the pump 1 Keep the motor dry Do not direct stream from pump discharge onto the mo...

Page 5: ...able and with all local codes and ordinances that apply Consult your local building inspector for code information NOTICE Clamp the power cable to prevent strain on the terminal screws NOTICE Your Mot...

Page 6: ...receptacle Do not modify or remove plug Make sure pump circuit meets National Electrical Code To avoid dangerous electrical shock hazard keep cord dry at all times Models without cord and plug 1 Conne...

Page 7: ...y 4 With one 7 16 wrench in place on motor shaft place second wrench on shaft hex at pump end and unscrew impeller stack by turning counter clockwise 5 Once loose from motor shaft hold shaft by snap r...

Page 8: ...cavity using a 3 4 socket or a piece of 3 4 standard pipe D Be sure polished surface of seat is free of dirt and has not been damaged by insertion Re move excess soapy water Dispose of card board was...

Page 9: ...ur warranty is void Buyer s only remedy and Sta Rite s only duty is to repair or replace defective products at Sta Rite s choice Buyer agrees to pay all labor and shipping charges associated with this...

Page 10: ...10 1 13 12 10 2 3 4 5 5 6 7 8 9 11 1206 0894 Figure 8 Exploded view...

Page 11: ...230 Volt Three Phase 1 AP100CH AP100DH AP100EH AP100EH AP100FH 2 Handle 1 C54 21 C54 21 C54 21 C54 21 C54 21 3 Water Slinger 1 C69 2 C69 2 C69 2 C69 2 C69 2 4 Pump Body 1 C2 85 C2 85 C2 85 C2 85 C2 85...