INSPECT THE SHIPMENT
The high pressure booster pump has been carefully
inspected and packaged to assure safe delivery.
Inspect the pump and fittings and report to the carrier
any items which are damaged or missing.
INSTALLATION
The pump is designed to boost city water pressure or
water pressure from a private water system. Use this
high pressure stream to wash down milk parlors, barns,
garages and driveways, or for fire protection.
The pump is portable with a convenient carrying
handle. If an existing pressure water system is to be
used as a water supply, it can be connected with
available fittings and 3/4” or 1” high pressure hose to
the pump inlet. A special heavy duty 3/4” or 1” suction
hose with fittings is available as an accessory. If pump
is permanently mounted on wall, use a 3/4” or 1” pipe
or heavy-duty hose for suction line. 20 GPM models
require one-inch discharge hose to reduce friction
losses.
TABLE I - DISCHARGE PRESSURE
Discharge Discharge
Rated
Pressure
Pressure
No. of
Flow
PSI at
PSI at
Series
HP
Stages in GPM Rated Flow
No Flow
HP7C, HP7C3
1/2
9
7
90
130
HP7D, HP7D3
3/4
12
7
123
173
HP7E, HP7E3
1
16
7
162
229
HP20E, HP20E3
1
7
20
75
110
HP20F, HP20F3 1-1/2
9
20
97
143
*For total discharge pressure, add this pressure to suction pipe
pressure. For example, an HP7C pump taking suction from a 100 psi
water service line will produce 130 + 100 = 230 psi total discharge
pressure at 0 GPM flow. If suction pressure drops to 50 psi,
discharge pressure will drop to 180 psi.
Hazardous pressure. Pump body may
explode if pressures exceed rated limits. Maximum
inlet pressure is 80 PSI. Maximum discharge pressure is
315 PSI. Warranty is void if these pressure limits are
exceeded.
HIGH PRESSURE BOOSTER PUMP
INSTALLATION INSTRUCTIONS
These instructions cover high pressure booster pump
installations as shown below:
3
Figure 1 – Connection to house service.
1208 0894
To pressurized
house service
Suction
Discharge
Figure 2 – Connection to water reservoir.
1207 0894
Water tank
or reservoir
Suction
Discharge
Figure 3 – Cistern or shallow well installation.
Male Pipe to Male Hose Adapter
Female Hose Connection
Male Hose
Connection
High Pressure
Hose
20 Feet
Maximum
Gun Nozzle
Weeping Type ONLY
Priming Plug
Tee
90 Elbow
Water Supply
Foot Valve
1210 0894