ELECTRICAL SAFETY

Some models of

pump are supplied

with 3-connector
grounding type cord.
Connect only to properly
grounded, GFCI protected
outlet. Do not lift pump by
electrical cord.

Pump is non-

submersible. Keep

motor dry at all times. Do
not wash motor. Do not
immerse. Protect motor
from wet weather.

If using extension

cord, use only UL

approved indoor/outdoor,

3-wire, grounding type cord. Do not allow any part
of cord or receptacle ends to sit in water or damp
locations.

Unplug pump before servicing.

Burn Hazard. Do not touch an oper-

ating motor. Modern motors are designed to operate at
high temperatures. To avoid burns when servicing
pump, allow it to cool for 20 minutes after shut-down
before handling.

Follow local and/or national plumbing and electrical
codes when installing.

Hazardous Pressure. DO NOT run the

pump with discharge shutoff, as hose may burst or
pump may be damaged due to high temperatures.

READ AND FOLLOW 
SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury:

DANGER warns about hazards that will cause serious
personal injury, death or major property damage if
ignored.

WARNING warns about hazards that can cause serious
personal injury, death or major property damage if
ignored.

CAUTION warns about hazards that will or can cause
minor personal injury or property damage if ignored.

The word NOTICE indicates special instructions which
are important but not related to hazards.

GENERAL SAFETY

To avoid risk of serious bodily injury and property
damage, read safety instructions carefully before
installing pump.
Do not allow pump or any system component to freeze.
To do so may damage system and will void warranty.

Risk of electric shock. To avoid fatal

shocks, proceed as follows if pump needs servicing.
A. Disconnect power to pump outlet box before pul-

ling pump cord plug. After plug is pulled, let pump
cool for 20 minutes before attempting to work on it.

B. Take extreme care when changing fuses. To re-

duced chance of fatal electrical shocks, DO NOT
stand in water or put your finger in the fuse socket.

C. Ground electrical outlet box.
D. Use only Ground Fault Circuit Interrupter (GFCI)

protected grounded outlet for cord plug.

Never run pump dry. Running pump dry can damage
internal parts, overheat pump (which can cause burns to
people handling or servicing pump), and will void
warranty.

Do not pump chemicals or corrosive liquids with pump.

Hazardous Pressure.

A. Use high pressure reinforced type discharge

hose ONLY. See parts list for available hose, nozzle
and fittings. A high pressure relief valve is recom-
mended.

B. DO NOT use garden hose with High Pressure

Booster pump. Garden hose will not stand the
discharge pressure produced and will fail.

C. High pressure discharge stream is dangerous. To

avoid injury, DO NOT aim the discharge stream at
any person or animal.

D. BE SURE that the pump suction pipe pressure

plus the pump discharge pressure does not
exceed the pressure rating of hose and fittings.
See Table I for pump discharge pressure ratings.

2

WARNING

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before
connecting to power
supply.

Summary of Contents for Signature 2000 HP20E-01

Page 1: ...rough 1 1 2 HP STA RITE INDUSTRIES INC DELAVAN WISCONSIN 53115 Printed in U S A 1998 Sta Rite Industries Inc S327 Rev 6 23 98 MODEL HP PHASE AVG GPM HP7C 01 1 2 1 7 HP7C3 01 1 2 3 7 HP7D 01 3 4 1 7 HP...

Page 2: ...important but not related to hazards GENERAL SAFETY To avoid risk of serious bodily injury and property damage read safety instructions carefully before installing pump Do not allow pump or any system...

Page 3: ...GPM Rated Flow No Flow HP7C HP7C3 1 2 9 7 90 130 HP7D HP7D3 3 4 12 7 123 173 HP7E HP7E3 1 16 7 162 229 HP20E HP20E3 1 7 20 75 110 HP20F HP20F3 1 1 2 9 20 97 143 For total discharge pressure add this p...

Page 4: ...pump to replace seal See Maintenance Pages 7 and 8 OPERATION NOTICE Observe the following precautions when operating the pump 1 Keep the motor dry Do not direct stream from pump discharge onto the mo...

Page 5: ...able and with all local codes and ordinances that apply Consult your local building inspector for code information NOTICE Clamp the power cable to prevent strain on the terminal screws NOTICE Your Mot...

Page 6: ...receptacle Do not modify or remove plug Make sure pump circuit meets National Electrical Code To avoid dangerous electrical shock hazard keep cord dry at all times Models without cord and plug 1 Conne...

Page 7: ...y 4 With one 7 16 wrench in place on motor shaft place second wrench on shaft hex at pump end and unscrew impeller stack by turning counter clockwise 5 Once loose from motor shaft hold shaft by snap r...

Page 8: ...cavity using a 3 4 socket or a piece of 3 4 standard pipe D Be sure polished surface of seat is free of dirt and has not been damaged by insertion Re move excess soapy water Dispose of card board was...

Page 9: ...ur warranty is void Buyer s only remedy and Sta Rite s only duty is to repair or replace defective products at Sta Rite s choice Buyer agrees to pay all labor and shipping charges associated with this...

Page 10: ...10 1 13 12 10 2 3 4 5 5 6 7 8 9 11 1206 0894 Figure 8 Exploded view...

Page 11: ...230 Volt Three Phase 1 AP100CH AP100DH AP100EH AP100EH AP100FH 2 Handle 1 C54 21 C54 21 C54 21 C54 21 C54 21 3 Water Slinger 1 C69 2 C69 2 C69 2 C69 2 C69 2 4 Pump Body 1 C2 85 C2 85 C2 85 C2 85 C2 85...

Reviews: