background image

19

1

2

3

4

5

6

7

8

9

10

11

12

13

14

1782 0495

Key

Part

-03

-04

-11

No.

Description

Qty.

Systems

Systems

Systems

1

Union Collar

1

U11-182P1

U11-182P1

U11-182P1

2

Union Half & Nipple Assembly

1

25010-0202

25010-0202

25010-0202

3

O-ring, Union Coupling

1

U9-226

U9-226

U9-226

4

Pump - 3/4 HP

1

JWPA5D7L-2A2

JWPA5D7L-2A2

4

Pump - 1 HP

1

JWPA5E7L-2A2

JWPA5E7L-2A2

JWPA5E7L-2A1

5

Capscrew

4

37337-0084

37337-0084

37337-0084

6

Flat Washer

4

U43-60SS

U43-60SS

U43-60SS

7

Pump Spacer

2

25010-0006

25010-0006

25010-0006

8

Platform Base

1

WC4-126P

WC4-126P

WC4-126P

9

Hex Nut

2

U36-105SS

U36-105SS

U36-105SS

10

Flat Washer

2

U43-20SS

U43-20SS

U43-20SS

11

Capscrew

2

U30-871SS

U30-871SS

U30-871SS

12

Hose 1-1/2" x 77"

2

34055-7038

34055-7038

13

Hose Clamp

4

P19-29

P19-29

14

Hose Adapter

2

11201-0002

11201-0002

REPAIR PARTS LIST

EXPLODED VIEW

Summary of Contents for PTM50JWAD-03

Page 1: ...Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Dela...

Page 2: ...mes 3 Risk of electrical shock Connect only to a grounding type receptacle protected by a ground fault circuit interrupter GFCI Contact a qualified electri cian if you cannot verify that the receptacl...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing BE SUR...

Page 4: ...swimming pools only NOTICE Some pool disinfectants may clog filter media To maximize media life and filter cycle time closely follow disinfectant manufacturer s instructions when cleaning pool or fil...

Page 5: ...p suction inlet below pool water level at all times this al lows pump to prime Have adequate ventilation to prevent motor overheating Be protected from excess moisture such as water puddles or rain ru...

Page 6: ...ps must be kept securely hand tight to prevent leaks and prevent tank blowup when filter is under pres sure If it is necessary to work on filter or do anything to clamps do this 1 Stop pump 2 Close is...

Page 7: ...provided Use as follows for leak free connections 1 O Ring and sealing surfaces must be clean 2 Assemble handtight only NO WRENCHES 3 NO pipe compound or Teflon tape on unions On 03 systems use hoses...

Page 8: ...physical damage to avoid serious or fatal electrical shock hazard Plug the System into a GFCI receptacle on a 115 Volt 60 Hertz grounded cir cuit only Electrically isolate circuit so that no other lig...

Page 9: ...pen system valves and make sure pump is filled with water 3 Start pump circulating water NOTICE To prevent pump from running dry be sure water level never drops below bottom of skimmer inlet Add water...

Page 10: ...ized replacement parts when servicing system GENERAL No lubrication or regular mechanical maintenance are needed Wash outside of filter with a mild detergent and water Rinse off with hose NOTICE DO NO...

Page 11: ...t to damage O Ring Place tank head in clean area NOTICE If heavy dirt deposits have collected around bottom of filter ele ment and base wash out base before removing element 9 Remove O Ring from tank...

Page 12: ...ile tightening knob s 9 Clean pump strainer basket 10 Open system valves as needed 11 Proceed to Startup Page 9 STA RITE APPROVED O RING LUBRICANTS Parker Super O Lube Semi Permanent Lubrication Aqua...

Page 13: ...roceed as follows 1 Follow Regular Cleaning Procedure 2 If deposits remain soak element at least one hour with one of the follow ing solutions A Commercial filter cleaner see chart follow manufacturer...

Page 14: ...t be clean and free of dirt grease dust etc Wet rub ber cup gasket of ceramic seat with small amount of liquid detergent press into cavity firmly and squarely with finger pressure Figure 15 2 If ceram...

Page 15: ...h retain water with non toxic propylene glycol antifreeze RV antifreeze 4 Drain all water from pump and piping when expecting freezing tempera tures or when storing pump for a long time see instructio...

Page 16: ...vice on Page 14 4 Consult with dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in pool is at least 2 51mm above bottom of skimmer throat w...

Page 17: ...de as recom mended by pool manufacturer Continue until algae is controlled B Low flow 1 Element is plugged see Special Cleaning Instructions Page 13 2 Pipe blocked downstream from filter remove obstru...

Page 18: ...ed properly in filter base follow instructions under Filter Disassembly Reassembly Pages 11 and 12 and reposition properly 4 Filter is plumbed backwards and element cloth is ruptured replumb properly...

Page 19: ...Pump 1 HP 1 JWPA5E7L 2A2 JWPA5E7L 2A2 JWPA5E7L 2A1 5 Capscrew 4 37337 0084 37337 0084 37337 0084 6 Flat Washer 4 U43 60SS U43 60SS U43 60SS 7 Pump Spacer 2 25010 0006 25010 0006 25010 0006 8 Platform...

Page 20: ...Plug 2 WC78 38T WC78 38T 10 Nut Clamp 1 WC36 1 WC36 1 11 Clamp 1 25010 9100 25010 9100 12 Air Bleed Tube 1 25010 0007 25010 0007 13 Filter Air Bleed Tube 1 WC8 35 WC8 35 14 Clamp 1 25010 9101 25010 9...

Page 21: ...U178 920P U178 920P 14 Washer Flat 5 16 4 U43 41SS U43 41SS 15 Capscrew 5 16 18x1 1 4 4 U30 64SS U30 64SS 16 Washer Lock 5 16 4 U43 11SS U43 11SS 17 Gasket 1 C20 123 C20 123 18 Drain Plug 2 WC78 40T...

Page 22: ...22...

Page 23: ...pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to replace t...

Page 24: ...24...