7
TABLE I - RECOMMENDED FUSING AND WIRING DATA
Model
Motor Branch Fuse Max Load
Voltage/
Dist. in Ft. (m) (Serv. to Motor)
Temp.
Number
H.P.
Rating Amps*
Amps
Hz/Phase
0-100’ (0-30)
101-200’ (31-60) 201-300’ (61-90)
Rating-°C
1-Speed
JWPA5C-2A8
1/2
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5DL-2A
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5DL-2A1
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5DL-2A2
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5D-2A
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5D-2A4
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5D-2A8
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5D7L-2A
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5D7L-2A1
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5D7L-2A2
3/4
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
JWPA5EL-2A
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5EL-2A1
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5EL-2A2
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5E7-2A4
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5E7L-2A
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5E7L-2A1
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5E7L-2A2
1
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5F-2A
1
1
⁄
2
20
16
115/60/1
10 (5.5)
8 (8.4)
6 (14)
75
JWPA5FL-2A
1
1
⁄
2
20
16
115/60/1
10 (5.5)
8 (8.4)
6 (14)
75
JWPA5FL-2A1
1
1
⁄
2
20
16
115/60/1
10 (5.5)
8 (8.4)
6 (14)
75
JWPA5FL-2A2
1
1
⁄
2
20
16
115/60/1
10 (5.5)
8 (8.4)
6 (14)
75
JWPA5FL-A
1
1
⁄
2
25/15
16.4/8.2 115/230/60/1 10/14 (5.5/2)
8/14 (8.4/2)
6/12 (14/3)
75
JWPA5F7L-2A4
1
1
⁄
2
20
16
115/60/1
10 (5.5)
8 (8.4)
6 (14)
75
JWPS5FL-A2
1
1
⁄
2
15
12.0
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5D-230A
3/4
15
4.8
230/60/1
14 (2)
14 (2)
14 (2)
75
JWPA5E-230A
1
15
6.1
230/60/1
14 (2)
14 (2)
14 (2)
75
JWPA5E-230A2
1
15
6.1
230/60/1
14 (2)
14 (2)
14 (2)
75
JWPS5EL-A2
1
15
9.0
115/60/1
14 (2)
12 (3)
10 (5.5)
75
2-Speed
JWPXYD-A2
3/4 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPXYDL-A2
3/4 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPAXYE-A2
1 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5YEL-A1
1 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5YEL-A2
1 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5YE7L-A1 1 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5YE7L-A2 1 – 1/8
15
11.7/3.39
115/60/1
14 (2)
10 (5.5)
8 (8.4)
75
JWPA5YFL-A
1
1
⁄
2
– 1/6
20
16.0/3.6
115/60/1
12 (3)
8 (8.4)
6 (14)
75
JWPA5YFL-A2 1
1
⁄
2
– 1/6
20
16.0/3.6
115/60/1
12 (3)
8 (8.4)
6 (14)
75
JWPA5YF7L-A1 1
1
⁄
2
– 1/6
20
16.0/3.6
115/60/1
12 (3)
8 (8.4)
6 (14)
75
JWPA5YF7L-A2 1
1
⁄
2
– 1/6
20
16.0/3.6
115/60/1
12 (3)
8 (8.4)
6 (14)
75
*Time delay fuses are recommended instead of standard fuses in any motor circuit.
Wire Size AWG (mm)
}
Values given in table below are for PUMP MOTOR ONLY. If additional accessories are
installed on pump motor circuit (heater, blower, etc.), include their amperage draw
when figuring wire and circuit breaker sizes.