background image

3

READ AND FOLLOW ALL 
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your system

or in this manual, look for one of the following signal words and be alert

to the potential for personal injury.

warns about hazards that will cause death, serious personal in-

jury, or major property damage if ignored.

warns about hazards that can cause death, serious personal in-

jury, or major property damage if ignored.

warns about hazards that will or can cause minor personal injury

or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip-
ment. 
Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 
Read and follow instructions in owner's manual when installing

and operating equipment. Have a trained pool professional perform all pres-
sure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system

before operating or testing equipment.

Before pressure testing, make the following safety checks:

• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
• Water pressure for test must be less than 25 PSI (172 kPa).
• Water Temperature for test must be less than 100

o

F. (38

o

C).

• Limit test to 24 hours. After test, visually check system to be sure it is ready

for operation. Remove trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For 
non-Sta-Rite equipment, consult manufacturer.

IMPORTANT
SAFETY 
INSTRUCTIONS

Always follow basic safety pre-
cautions with this equipment, in-
cluding the following.

To reduce the risk of

injury, do not permit children to
use this product unless they are
closely supervised at all times.

This pump is  for

use with permanently installed
pools and may also be used with
hot tubs and spas if so marked.
Do not use with storable pools. A
permanently installed pool is con-
structed in or on the ground or in
a building such that it cannot be
readily disassembled for storage.
A storable pool is constructed so
that it may be readily disassem-
bled for storage and reassembled
to its original integrity.

SAVE THESE 
INSTRUCTIONS

Summary of Contents for DURA-JET 5JTAC-A

Page 1: ...al 800 752 0183 FAX 800 582 2217 Canada 416 629 1611 FAX 416 629 3726 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Orlando FL Union City TN Delavan WI Mississauga Ont Printe...

Page 2: ...ts sole discretion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for warranty service must be made through the installing dealer...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Page 4: ...Piping Use flexible or rigid PVC pipe for connections to pump Use at least 1 1 2 IPS pipe Fittings restrict flow for best efficiency use fewest possible fittings Unions are provided Use as follows for...

Page 5: ...solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or condu...

Page 6: ...tor is running at full load consult power company TABLE I RECOMMENDED WIRING DATA 50 HZ 230V MOTORS Dist in Ft M Service to Motor Model Motor 0 100 101 200 201 300 Temp No H P 0 30 31 60 61 90 Rating...

Page 7: ...erature and gradually increase it according to your experience Keep an accurate thermometer in bath check it before getting in Do not use or allow the use of the tub by anyone using alcohol or drugs T...

Page 8: ...unterclockwise Rotating half of seal will come off with impeller NOTICE Pump may have spacing shims inside impeller sleeve against shaft shoulder Do not lose or damage shims If impeller needs replace...

Page 9: ...onto impeller sleeve until drive ring bottoms on impeller back shroud 4 Slip slinger over shaft remount seal plate Torque throughbolts to 25 inch lbs 29 cm kg 5 Impeller shim s if used go over threade...

Page 10: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Page 11: ...260P 9 Seal 1 U9 358SS U9 358SS 10 Impeller 1 C5 228PB C5 229PA 11 O Ring 1 U9 357 U9 357 12 Front Plate 1 C1 261P C1 261P 13 Washer 1 4 Plain 6 U43 117SS U43 117SS 14 Washer 1 4 Lock 6 U43 10SS U43...

Reviews: