TROUBLESHOOTING GUIDE

Read and understand safety and operating instructions in this manual

before doing any work on pump!

A. PUMP DOES NOT OPERATE

1. Check GFCI for proper operation according to GFCI manufacturer’s in-

structions.

2. Check for plugged impeller. Follow disassembly/assembly instructions

under “Pump Service”, Page 8.

3. Consult dealer/installer or service representative.

B. IMPROPER JET ACTION

1. Check for blocked fittings. Blocked fittings will cause poor flow and poor jet

action.

2. Consult dealer/installer or service representative.

C. EXCESSIVE AIR IN SYSTEM – PUMP LOSES PRIME

1. Make sure water level in spa is at least 2" (51 mm) above top of jets with sys-

tem not operating.

2. Make sure there are no leaks in suction piping.
3. Make sure there is no vortex (whirlpool) at the suction.
4. Consult dealer/installer or service representative.

D. CIRCUIT BREAKER IN HOME PANEL TRIPS REPEATEDLY

1. Breaker must be of adequate capacity.
2. For GFCI breaker: test according to GFCI manufacturer’s instructions.
3. Make sure no other lights and appliances are on circuit.
4. Consult dealer/installer or service representative.

Summary of Contents for DURA-JET 5JTAC-A

Page 1: ...al 800 752 0183 FAX 800 582 2217 Canada 416 629 1611 FAX 416 629 3726 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Orlando FL Union City TN Delavan WI Mississauga Ont Printe...

Page 2: ...ts sole discretion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for warranty service must be made through the installing dealer...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Page 4: ...Piping Use flexible or rigid PVC pipe for connections to pump Use at least 1 1 2 IPS pipe Fittings restrict flow for best efficiency use fewest possible fittings Unions are provided Use as follows for...

Page 5: ...solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or condu...

Page 6: ...tor is running at full load consult power company TABLE I RECOMMENDED WIRING DATA 50 HZ 230V MOTORS Dist in Ft M Service to Motor Model Motor 0 100 101 200 201 300 Temp No H P 0 30 31 60 61 90 Rating...

Page 7: ...erature and gradually increase it according to your experience Keep an accurate thermometer in bath check it before getting in Do not use or allow the use of the tub by anyone using alcohol or drugs T...

Page 8: ...unterclockwise Rotating half of seal will come off with impeller NOTICE Pump may have spacing shims inside impeller sleeve against shaft shoulder Do not lose or damage shims If impeller needs replace...

Page 9: ...onto impeller sleeve until drive ring bottoms on impeller back shroud 4 Slip slinger over shaft remount seal plate Torque throughbolts to 25 inch lbs 29 cm kg 5 Impeller shim s if used go over threade...

Page 10: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Page 11: ...260P 9 Seal 1 U9 358SS U9 358SS 10 Impeller 1 C5 228PB C5 229PA 11 O Ring 1 U9 357 U9 357 12 Front Plate 1 C1 261P C1 261P 13 Washer 1 4 Plain 6 U43 117SS U43 117SS 14 Washer 1 4 Lock 6 U43 10SS U43...

Reviews: